1、Designation: D 7478/D 7478M 081Standard Specification forHeavy Duty Sheathed Wood Crates1This standard is issued under the fixed designation D 7478/D 7478M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTESubsection 6.2.5 was editorially corrected in April 2009.1. Scope1.1 This specification covers requirements for two types andtwo classes of
3、 sheathed crates each of which may have twobase styles. The crates are designed for net loads not exceeding30 000 pounds lb 13 607 kg and to withstand the most severeoverseas shipping and storage conditions.1.2 The crates described by this specification are intended toprotect items from atmospheric
4、elements during shipment andstorage. They are designed to withstand the rough handling oflogistic operations including stacking and outside storage for aprolonged period.1.3 Class 1 and 2 crates may be used interchangeably asdesired. However, the Class 2 crate should be used whenweight is a prime co
5、nsideration, as the lack of diagonals andthinner plywood sheathing results in a lighter crate.1.4 Demountable crates, Type II, should be used wheneverit is expected that the contained item will require reshipping toanother destination.1.5 Sill bases, Style B, are intended for items that projectbelow
6、 their mounting points, such as disassembled vehicles.1.6 If the use of other construction method or techniques isacceptable and permitted (see 5.10), the resulting packagingsystems shall be of equal or better performance than wouldresult from the use of these specified materials and procedures.The
7、appropriate distribution cycle, specified in Practice D 4169can be used to develop comparative procedures and criteria.1.7 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachs
8、ystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard. See IEEE/ASTM SI 10 for conversion ofunits.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsib
9、ility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 996 Terminology of Packaging and Distribution Environ-mentsD 3953 Specification for Strapping,
10、 Flat Steel and SealsD 4169 Practice for Performance Testing of Shipping Con-tainers and SystemsD 4442 Test Methods for Direct Moisture Content Measure-ment of Wood and Wood-Base MaterialsD 6199 Practice for Quality of Wood Members of Contain-ers and PalletsF 1667 Specification for Driven Fasteners:
11、 Nails, Spikes,and Staples2.2 National Institute of Standards and Technology (NIST)Standards:PS1 Voluntary Product Standard, Structural Plywood3PS20 American Softwood Lumber Standard42.3 Hardwood Plywood and Veneer Association Standard:5ANSI/HPVA HP-1 American National Standard for Hard-wood and Dec
12、orative Plywood2.4 National Hardwood Lumber Association (NHLA) Stan-dard:6Rules for the Measurement and Inspection of Hardwoodand Cypress1This specification is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.12 on ShippingContainers, Crat
13、es, Pallets, Skids and Related Structures.Current edition approved Oct. 1, 2008. Published November 2008.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standar
14、ds Document Summary page onthe ASTM website.3Available from APA, The Engineered Wood Association, 7011 South 19th St.,Tacoma, WA 984665399, http:/www.apawood.org.4Available from American Lumber Standards Committee, Inc., (ALSC), P.O.Box 210, Germantown, MD 208750210, http:/www.alsc.org.5Available fr
15、om Hardwood Plywood and Veneer Association (HPVA), P.O. Box2789, Reston, VA 220900789, http:/www.hpva.org.6Available from National Hardwood Lumber Association (NHLA), 6830 Ra-leigh LaGrange Rd., Memphis, TN 38134, http:/www.natlhardwood.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
16、x C700, West Conshohocken, PA 19428-2959, United States.2.5 ASME/ANSI Standards:7B18.2.1 Square and Hex Bolts and Screws Inch SeriesB18.5 Round Head Bolts (Inch Series)B18.22.l (B18.22M) Plain Washers3. Terminology3.1 DefinitionsGeneral definitions for packaging and dis-tribution environments are fo
17、und in Terminology D 996.3.2 Definitions of Terms Specific to This StandardThecrate component parts discussed herein were selected on thebasis of part function. Alternate names are sometimes used byindustry.3.2.1 diagonalsdiagonals are frame members positionedbetween parallel frame members and place
18、d at nearly 45angles to them. Diagonals serve as braces and ensure rigidity inthe crate.3.2.2 end frame membersend frame members are similarto side frame members but perpendicular to the long dimen-sion.3.2.3 filler stripsfiller strips are boards placed across theends of thin, non-load-bearing floor
19、boards, which serve to fillthe space below the lower frame member of the crate sides.3.2.4 frame membersframe members are those partswhich form the fundamental crate structure upon which thestrength and rigidity of a lumber-sheathed crate depends.3.2.5 hanger-metalhanger-metal is a metal nailed stra
20、pused to aid in support of the intermediate sill in sill-type bases.3.2.6 headersheaders are either transverse members ateach end of skid bases or longitudinal members at each end oftop joists. Headers in bases serve to hold the base together asa unit, to transfer loads to outside skids, and to prov
21、ide afastening member for end panels. Headers in top panels serveto position and support joists and to provide a fasteningmember for side panels.3.2.7 horizontal braceshorizontal braces are memberspositioned between struts and parallel to the upper and lowerframe members and serve to reduce the unsu
22、pported span ofthe sheathing.3.2.8 joistsjoists are members extending across the crateunderneath the top, which serve to support and transfer verticalstacking loads to the side panels. Joists also serve to preventcrushing or buckling of crate tops when slings or grab hooksare used.3.2.9 lag screw st
23、raplag screw strap is a metal reinforcingstrap used on bolted crates sides and ends to reinforce andincrease lag screw lateral resistance.3.2.10 load-bearing floorboardsload-bearing floorboardsare transverse base members which serve to distribute andtransfer loads to the outside skids.3.2.11 rubbing
24、 stripsrubbing strips are longitudinal mem-bers nailed to the skid bottom to provide for sling and forklifttruck handling.3.2.12 sheathingsheathing is the plywood or boardsnailed to the frame members and enclose the crate. Sheathingused on the top panels is called top sheathing; that used on theside
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7478D7478M2008E1374STANDARDSPECIFICATIONFORHEAVYDUTYSHEATHEDWOODCRATES 重载 封装 木箱 标准规范 PDF

链接地址:http://www.mydoc123.com/p-525606.html