ASTM D7198-2005 Standard Specification for Disposable Embalming Gloves for Single-Use Applications《一次性防腐手套的标准规范》.pdf
《ASTM D7198-2005 Standard Specification for Disposable Embalming Gloves for Single-Use Applications《一次性防腐手套的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7198-2005 Standard Specification for Disposable Embalming Gloves for Single-Use Applications《一次性防腐手套的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7198 05Standard Specification forDisposable Embalming Gloves for Single-Use Applications1This standard is issued under the fixed designation D 7198; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers certain requirements for natu-ral rubber (Latex), synthetic rubber (Polychloroprene andNitrile), a
3、nd vinyl (PVC) disposable gloves for use in conduct-ing single-use embalming procedures.1.2 This specification covers natural rubber (Latex), syn-thetic rubber (Polychloroprene and Nitrile), and Vinyl (PVC)disposable gloves that fit either hand, paired gloves, gloves bysize, and gloves packed in bul
4、k.1.3 An assessment to measure the chemical resistanceperformance of the glove can be made based on the ultimatepermeation (breakthrough) of embalming chemicals throughthe glove material over a specified period of time.1.4 This specification is similar to the following specifica-tions: D 3578, D 467
5、9, D 5250, D 6319, and D 6977.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of t
6、his standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 412 Test Methods for Vulcanized Rubber and Thermo-plastic Elastomers-TensionD 573 Test Method for Rubber-Deteriorati
7、on in anAir OvenD 3578 Specification for Rubber Examination GlovesD 3767 Practice for Rubber-Measurement of DimensionsD 4679 Specification for Rubber General Purpose, House-hold or Beautician GlovesD 5151 Test Method for Detection of Holes in MedicalGlovesD 5250 Specification for Poly(vinyl chloride
8、) Gloves forMedical ApplicationD 5712 Test Method for Analysis of Aqueous ExtractableProtein in Natural Rubber and Its Products Using theModified Lowry MethodD 6124 Test Method for Residual Powder on MedicalGlovesD 6319 Specification for Nitrile Examination Gloves forMedical ApplicationD 6499 Test M
9、ethod for the Immunological Measurementof Antigenic Protein in Natural Rubber and its ProductsD 6977 Specification for Polychloroprene ExaminationGloves for Medical ApplicationF 739 Test Method for Resistance of Protective ClothingMaterials to Permeation by Liquids or Gases Under Con-ditions of Cont
10、inuous Contact2.2 ISO Standard:ISO 2859 Sampling Procedures and Tables for Inspectionby Attributes32.3 Other Document:U.S. Pharmacopeia43. Significance and Use3.1 This specification is intended to be a specification forevaluating the performance and quality of disposable naturalrubber, synthetic rub
11、ber, and vinyl (PVC) gloves for single-useembalming applications.3.2 The safe and proper use of disposable natural rubber,synthetic rubber (polychloroprene and nitrile), and vinyl glovesis beyond the scope of this specification.3.3 The chemical permeation tests described in this speci-fication are i
12、ntended to be “Type Tests” for these types ofgloves.3.3.1 The chemical permeation tests are not intended to betesting instructions nor testing protocols to be used for routinelot release.4. Materials and Manufacture4.1 Any natural rubber, synthetic rubber, and plastic poly-mer compound may be used t
13、hat permits the glove to meet therequirements of this specification.1This specification is under the jurisdiction ofASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.40 on Consumer RubberProducts.Current edition approved Oct. 1, 2005. Published November 2005.2For refer
14、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43r
15、d St.,4th Floor, New York, NY 10036.4U. S. Pharmacopeia, latest edition, Mack Publishing Co., Easton, PA 19175.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 A lubricant that meets the current requirements of theU.S. Pharmacopoe
16、ia for absorbable dusting powder may beapplied to the glove. Other lubricants may be used if theirsafety and efficacy have been previously established.4.3 The inside and outside surface of the natural rubber,synthetic rubber, and plastic disposable gloves shall be free oftalc.5. Sampling5.1 For refe
17、ree purposes, gloves shall be sampled fromfinished product and inspected in accordance with ISO 2859.The inspection levels and acceptable quality levels (AQL) shallconform to those specified in Table 1, or as agreed uponbetween the purchaser and the seller, if the latter is morecomprehensive.6. Perf
18、ormance Requirements6.1 Gloves shall be sampled in accordance with Section 5.6.2 Gloves shall meet the referee performance requirementsas described in Table 1.6.2.1 Shall comply with freedom from holes when tested inaccordance with 7.2.6.2.2 Have consistent physical dimensions in accordancewith 7.3.
19、6.2.3 Have acceptable physical property characteristics inaccordance with 7.4.6.2.4 Powder-free gloves shall have a recommended maxi-mum powder residue limit of 2.0 mg per glove in accordancewith 7.5 and A2.1.6.2.5 Powdered gloves shall have a recommended maxi-mum powder limit of 10 mg/dm2in accorda
20、nce with 7.6 andA2.2.6.2.6 Have a recommended aqueous soluble protein contentlimit of 200 g/dm2in accordance with 7.7 and Annex A1 orhave a recommended antigenic protein content limit of 10g/dm2in accordance with 7.8 and Annex A3.7. Test Methods7.1 The following tests shall be conducted to ensure th
21、erequirements of Section 8 are met, as prescribed in Table 1.7.2 Freedom from HolesTesting for freedom from holesshall be conducted in accordance with Test Method D 5151.7.3 Physical Dimensions Test:7.3.1 The gloves shall comply with the dimension require-ments prescribed in Tables 2-4.7.3.2 The len
22、gth shall be expressed in millimeters as mea-sured from the outside tip of the middle finger to the outsideedge of the cuff.7.3.3 The width of the palm shall be expressed in millime-ters as measured at a level between the base of the index fingerand the base of the thumb. Values of width per size ot
23、her thanlisted shall meet the stated tolerance specified in Tables 2-4.7.3.4 The minimum finger, palm, and cuff thicknesses shallbe expressed in millimeters as specified in Tables 2-4 whenusing a dial or digital micrometer that meets requirementsdescribed in Test Methods D 412 and Practice D 3767, a
24、nd inthe locations indicated in Fig. 1. For referee tests, cutting theglove is necessary to obtain single-wall thickness measure-ments. (See Practice D 3767 for more information.)7.4 Physical Requirements Test:7.4.1 Before and after accelerated aging, the gloves shallconform to the physical requirem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD71982005STANDARDSPECIFICATIONFORDISPOSABLEEMBALMINGGLOVESFORSINGLEUSEAPPLICATIONS 一次性 防腐 手套 标准规范

链接地址:http://www.mydoc123.com/p-524788.html