《ASTM D6830-2002(2008) 781 Standard Test Method for Characterizing the Pressure Drop and Filtration Performance of Cleanable Filter Media《可清洁的过滤器介质的压降和过滤特性表征的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6830-2002(2008) 781 Standard Test Method for Characterizing the Pressure Drop and Filtration Performance of Cleanable Filter Media《可清洁的过滤器介质的压降和过滤特性表征的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6830 02 (Reapproved 2008)Standard Test Method forCharacterizing the Pressure Drop and FiltrationPerformance of Cleanable Filter Media1This standard is issued under the fixed designation D 6830; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method characterizes the operational perfor-mance of cleanable filter
3、media under specified laboratoryconditions.1.2 This test method determines the airflow resistance, drag,cleaning requirements, and particulate filtration performance ofpulse cleaned filter media.1.3 This test method determines the comparative perfor-mance of cleanable filter media.1.4 The results ob
4、tained from this test method are useful inthe design, construction, and selection of filter media.1.5 The results obtained by this test method should not beused to predict absolute performance of full scale fabric filter(baghouse) facilities, however these results will be useful inselection of prope
5、r filter media and identification of recom-mended operating parameters for these full scale fabric filterfacilities.1.6 The values stated in SI units are to be regarded asstandard. The values in parenthesis are for information only.1.7 This standard does not purport to address all of thesafety conce
6、rns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 123 Terminology Relating to TextilesD
7、461 Test Methods for Felt3D 737 Test Method for Air Permeability of Textile FabricsE 832 Specification for Laboratory Filter PapersF 740 Definitions of Terms Relating to Filtration32.2 Other Standards:Draft Generic Verification Protocol for Baghouse FiltrationProducts4Standard Operating Procedures f
8、or Verification Testing ofBaghouse Filtration Products Using LTG/FEMA TestApparatus, Draft, December5VDI 3926, Part 2 Testing of Filter Media for CleanableFilters under Operational Conditions63. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 fabric conditioning periodthe period
9、during whichthe fabric specimen is conditioned within the test apparatus bysubjecting it to 10 000 rapid compressed air cleaning pulses at3-5 seconds between pulses. During the conditioning periodthe specimen is subjected to test method specifications for dustand gas flow rates.3.1.2 fabric recovery
10、 periodtime period following theconditioning period during which the fabric is allowed torecover from rapid pulsing. The fabric recovery period requires30 filtration cycles under normal filtration cycles. During therecovery period the fabric is subjected to test method specifi-cations for dust and g
11、as flow rates.3.1.3 filtration velocityvolumetric is the flow rate per unitface area. Also referred to as gas-to-cloth ratio (G/C), orair-to-cloth ratio (A/C).3.1.4 filtration cyclea cycle in the filtration process inwhich the particulate matter is allowed to form a dust cake onthe face area of the
12、test specimen with no disturbances from apulse of compressed air to clean the dust cake from the testspecimen. The filtration cycle is the time period between twoconsecutive cleaning or pulse cycles.3.1.5 filtration cycle timethe duration of time, measuredin seconds or minutes, defined by one filtra
13、tion cycle. Alsoreferred to as time between cleaning cycles, or pulse cycles.3.1.6 normal filtration cyclea filtration cycle specified forthis test method in which the dust cake is allowed to form on1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct res
14、ponsibility of Subcommittee D22.03 on AmbientAtmospheres and Source Emissions.Current edition approved April 1, 2008. Published July 2008. Originallyapproved in 2002. Last previous edition approved in 2002 as D 6830 - 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
15、 ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Generic Verification Protocol For Baghouse Filtration Products, RTI, ResearchTriangle Park, NC, September 2001.5Test/QA Plan For
16、 The Verification Testing of Baghouse Filtration Products,ETS, Inc., October 2000.6Verein Deutscher Ingenieure (VDI 3926, Part 2), 9Testing of Filter Media ForCleanable Filters under Operational Conditions,9 December, 1994. Availble fromBeuth Verlag GmBH, 10772 Berlin, Germany.1Copyright ASTM Intern
17、ational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the test specimen until a differential pressure of 1000 Pa (4 in.w.g.) is reached. At this point, the test specimen is cleaned bya pulse of compressed air from the clean gas side. After thepulse action is co
18、mpleted the next filtration cycle beginscontinuing until the pressure differential reaches 1000 Pa, thusinitiating the next pulse.3.1.7 PM- particulate matteralso used interchangeablywith “dust” when referring to test dust specifications or inletparticulate matter flow rates.3.1.8 PM 2.5particulate
19、matter nominally 2.5 microme-tres and less in equivalent aerodynamic diameter.3.1.9 performance test perioda 120 minute test periodfollowing the fabric recovery period (360 minutes minimumfor PM 2.5 measurements) during which measurements forparticulate emissions, residual pressure drop, number of f
20、iltra-tion cycles, and filtration cycle time are monitored and re-corded. During the performance test period pulse cleaning istriggered at a differential pressure of 1000 Pa (4 in. w.g.)measured across the test specimen. Gas and dust flows aremaintained at test specification flow rates.3.1.10 residu
21、al pressure dropthe air flow resistance mea-sured across the test specimen, as measured three seconds aftercleaning the test specimen with a pulse of compressed air,Alsoreferred to as residual differential pressure, P, residual delta P,or dPr,orDpr.3.2 For definitions of other terms used in this tes
22、t method,refer to Terminologies D 123 and F 740, as well as 11.1 of thistest method.4. Summary of Test Method4.1 A fabric filter sample is challenged with a standard dust(particulate matter) under simulated baghouse conditions atspecified rates for air and dust flow.4.2 The test consists of three te
23、st runs. Each run consists ofthree sequential phases or test periods during which dust andgas flow rates are continuously maintained to test specification.4.2.1 The test phases are:4.2.1.1 A conditioning period consisting of 10 000 rapidpulse filtration cycles to simulate long term operation,4.2.1.2
24、 A30 normal filtration cycle recovery period to allowthe test specimen to recover from rapid pulsing, and4.2.1.3 A two-hour performance test period, consisting ofnormal filtration cycles, during which measurements for par-ticulate emissions are determined by gravimetric measurementof the particulate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD683020022008781STANDARDTESTMETHODFORCHARACTERIZINGTHEPRESSUREDROPANDFILTRATIONPERFORMANCEOFCLEANABLEFILTERMEDIA

链接地址:http://www.mydoc123.com/p-523711.html