1、Designation: D 6633 05Standard Test Method forBasic Functional Stability of a Mechanical Pump Dispenser1This standard is issued under the fixed designation D 6633; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the basicfunctional stability of a mechanical pump dispenser with aproduct.1.2
3、This test method covers accelerated usage evaluations ofmechanical pump dispensers (spray or flow types) with aproduct.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pri
4、ate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tions are given in Section 5.2. Referenced Documents2.1 ASTM Standards:2D 2063 Test Methods for Measurement of Torque Retentionfor Packages with Continuous Thread ClosuresD 3890 T
5、est Method for Number of Strokes to Prime aMechanical Pump DispenserD 4336 Test Method for Determination of Output perStroke of a Mechanical Pump DispenserE 122 Practice for Calculating Sample Size to Estimate witha Specified Tolerable Error theAverage for a Characteristicof a Lot or Process3. Signi
6、ficance and Use3.1 This test method is used for determining the acceleratedusage of a mechanical pump dispenser for consumer usage.4. Apparatus4.1 Containers, that will allow the mechanical pump dis-penser to be affixed to them (Note 1) and also be capable ofcontaining product for a period of time a
7、t various environmen-tal conditions (Note 2).NOTE 1If possible, the actual container to be marketed should beused.4.2 Product, a sufficient amount to fill the number ofcontainers in accordance with 4.1, reference 10.2.4.3 Balance, with direct reading to 0.01 g. Top loading oranalytical style is reco
8、mmended.4.4 Environments, where the mechanical pump dispenserand product will be kept during the test period.4.4.1 Ambient Area, maintained at 23 6 3C (73 6 5.4F).4.4.2 Oven (45C), maintained at 45 6 3C (113 6 5.4F).NOTE 2The oven temperature can be changed according to productformulation. If differ
9、ent temperatures are used, this should be noted in thetest report discussed in 11.4.4.3 Cycle Chamber, optional, alternating 5 to 50C (41 to122F) every 24 h.4.5 Oven-Safe Tray, with absorbent paper towels laid in thetray.4.6 Food Coloring or Dye, optional.5. Precautions5.1 Appropriate handling consi
10、derations should be given toflammable, toxic, caustic, or other potentially hazardous ma-terial used. When testing at any temperature, safety should bethe number one consideration and special attention should beused on the flash points of the products tested.6. Sampling6.1 Based upon the desired pre
11、cision, sampling shall beperformed in accordance with Practice E 122.6.2 In the absence of any special sampling plan, perfor-mance shall be based on not less than the number of represen-tative specimens exposed to any of the environmental condi-tions as specified in Section 9.7. Test Specimen7.1 Tes
12、t specimens shall be clean, dry and previouslyunused mechanical pump dispensers.8. Conditioning8.1 If possible, condition the test specimens at 23 6 3C (736 5.4F) for not less than 4 h. If the test specimens are notconditioned at the recommended temperature, this should benoted in the test report di
13、scussed in 11.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.33 on MechanicalDispensers.Current edition approved Oct. 1, 2005. Published November 2005. Originallyapproved in 2001. Last previous edition approved in 20
14、01 as D 6633 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbo
15、r Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8.2 Test pumps should be tested no sooner than 24 h afterassembly when possible. If pumps are not conditioned at therecommended time, this should be noted in the test reportdiscussed in 11.9. Test Specimen Preparation9.1 Prepare a
16、 minimum of 12 mechanical pump dispenserswith product and containers to be used for accelerated usageevaluation.9.1.1 Affix the mechanical pump dispensers to containers atthe minimum recommended torque load in accordance withTest Method D 2063.9.1.2 Label all of the assembled units with the productn
17、ame, any safety hazards for the product, name of thetechnician completing the test, and the test number or means ofidentifying the test along with the following:9.1.2.1 Minimum 3 units labeled, “Upright, Ambient.”9.1.2.2 Minimum 3 units labeled, “Upright, Oven 45C.”9.1.2.3 Optional: Minimum 3 units
18、labeled, “Upright, CycleChamber.”9.1.2.4 Minimum 3 units labeled “On-Side, Ambient.”9.1.2.5 Minimum 3 units labeled, “On-Side, Oven 45C).”9.1.2.6 Optional: Minimum 3 units labeled “On-Side, CycleChamber.”10. Procedure10.1 Test each mechanical pump dispenser for strokes toprime in accordance with Tes
19、t Method D 3890. Report thefindings in 11.1.10.2 Test each mechanical pump dispenser for output perstroke in accordance with Test Methods D 4336. Visuallyinspect the spray or flow of the product to ensure that noobstructions are present.10.3 Place all of the test specimens as prepared in 9.1 intheir
20、 respective environments as indicated by the appropriatelabel on each unit. Except for trigger sprayers, place specimenslabeled “On-Side” with the orifice facing down. Triggersprayers may have the orifice oriented to the side while in the“on-side” position. If the mechanical pump dispensers use apro
21、tective hood or overcap, these test specimens should bestored with their protective devices in place. If the mechanicalpump dispensers have a locking feature, these test specimensshould be stored in the locked position during storage andunlocked for testing.10.4 Except for trigger sprayers, remove a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD66332005STANDARDTESTMETHODFORBASICFUNCTIONALSTABILITYOFAMECHANICALPUMPDISPENSER 机械 分配器 基本功能 稳定性

链接地址:http://www.mydoc123.com/p-523104.html