1、Designation: D4423 10 (Reapproved 2015)Standard Test Method forDetermination of Carbonyls in C4Hydrocarbons1This standard is issued under the fixed designation D4423; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of carbonyls(ketones and aldehydes) in C4hydrocarbons. This test methodwas teste
3、d on polymerization-grade 1,3-butadiene.1.2 The applicable range for this test method is 0 mgkg to50 mgkg carbonyls calculated as acetaldehyde.1.3 Other C4hydrocarbons and their mixtures besidespolymerization-grade 1,3-butadiene could be tested using thissame test method. However, the precision sect
4、ion of this testmethod covers only carbonyls in applicable range as listed in1.2, as found in polymerization-grade 1,3-butadiene.1.4 WARNINGMercury has been designated by manyregulatory agencies as a hazardous material that can causecentral nervous system, kidney and liver damage. Mercury, orits vap
5、or, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAswebsitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should
6、be aware that selling mercuryand/or mercury containing products into your state or countrymay be prohibited by law.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafet
7、y concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D484 Specification for Hydrocarbo
8、n Dry Cleaning Solvents(Withdrawn 1982)3D1193 Specification for Reagent WaterE1 Specification for ASTM Liquid-in-Glass Thermometers3. Summary of Test Method3.1 A measured amount of sample is added to an alcoholichydroxylamine hydrochloride solution that has been adjustedto a given coloration using e
9、ither alcoholic acid or base. Thecarbonyls will react with the hydroxylamine hydrochloridereleasing an equivalent amount of hydrochloric acid which isthen back-titrated to the original coloration.Ablank containingonly methanol and sample is titrated and the samples resultsare calculated using the bl
10、ank adjustment. Results are reportedas milligrams per kilogram carbonyls as acetaldehyde.4. Significance and Use4.1 The determination of the carbonyl content ofpolymerization-grade 1,3-butadiene is necessary, since in somepolymerization reactions, the presence of carbonyls in excessover some specifi
11、ed amount can have a deleterious effect uponthe polymer properties or the reaction itself, or both.5. Apparatus5.1 Bunsen ValvesAdevice constructed so that when usedwith an Erlenmeyer flask, the sample vapors can exit the flaskwhile protecting the flasks liquid contents. See Fig. 1 fordetails.5.2 Co
12、oling CoilPrepare a cooling coil by winding about10 cm to 15 cm of seamless copper tubing (about 6 mmdiameter) on a short length of pipe (about 1.5 cm to 2.0 cmdiameter), allowing sufficient length of tubing at the end of thecoil to connect it to the sample source.Attach a valve at a pointthat would
13、 not extend more than 8 cm above the surface of thecooling bath liquid. To the valve, attach a 6 cm to 8 cm length1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.D0.04 on C4 Hydro
14、carbons.Current edition approved April 1, 2015. Published May 2015. Originallyapproved in 1984. Last previous edition approved in 2010 as D4423 10. DOI:10.1520/D4423-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
15、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unite
16、d States1piece of tubing bent downward so that the hydrocarbon liquidcan be directed into the receiving container.5.3 Dewar FlaskThe Dewar flask must be of sufficientvolume to completely immerse the main portion of the coolingcoil except for the extremities necessary for receiving anddelivering the
17、sample through the coil.5.4 Erlenmeyer Flasks, 250 mL capacity.5.5 Volumetric Flasks, 1 L capacity. These flasks should beClass A glassware.5.6 Graduated Cylinders100 mL capacity, glasscylinders, graduated in 1 mL or 2 mL divisions.5.7 Microburets, 2.00 mL or 5.00 mL capacity. The mi-croburets shoul
18、d be Class A glassware with 0.01 mL or0.02 mL divisions or less. It is advisable to have the burets tipend equipped with a syringe needle to dispense very smalldrops of titrant.5.8 Sample CylindersThese should be of sufficient vol-ume to give the required amount of sample for testing.Stainless steel
19、 cylinders equipped with needle valves should beused. It is suggested that a 500 mL-capacity cylinder be theminimum size to be used for butadiene.5.9 ThermometerFor observing temperatures below45 C. The Low Cloud and Pour Point Thermometer, con-forming to the requirements for ASTM Thermometer 6C, as
20、prescribed in Specification E1, is satisfactory. Thermometer 6Chas a range from 80 C to +20 C. Temperature measuringdevices that cover the temperature range of interest, such as theASTM 1C thermometer, or liquid-in-glass thermometers,thermocouples, or platinum resistance thermometers that pro-vide e
21、quivalent or better accuracy and precision may be used.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals should beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American C
22、hemical Society wheresuch specifications are available.4Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shal
23、l be understood to mean Type II reagent waterconforming to Specification D1193.6.3 Alcoholic Hydrochloric Acid (0.05 N)Dilute 4.2 mLofconcentrated hydrochloric acid (WarningPoison. Corrosive.May be fatal if swallowed. Liquid and vapor cause severeburns. Harmful if inhaled.) to volume with anhydrous
24、methanolin a 1 L volumetric flask. Use the alcoholic 0.05 N potassiumhydroxide solution to standardize the HCl solution.6.4 Alcoholic Hydroxylamine HydrochlorideDissolve35.0 g of hydroxylamine hydrochloride (WarningMay beirritating to skin, eyes, or mucous membranes. Harmful ifinhaled.) in 3.5 L of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD442320102015STANDARDTESTMETHODFORDETERMINATIONOFCARBONYLSINC4HYDROCARBONS 测定 C4 碳氢化合物 羰基 化合物 标准

链接地址:http://www.mydoc123.com/p-517016.html