1、Designation: D3611 06 (Reapproved 2011)Standard Practice forAccelerated Aging of Pressure-Sensitive Tapes1This standard is issued under the fixed designation D3611; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice provides one environment in w
3、hich toexpose finished pressure-sensitive tape material for the purposeof accelerating the aging of it. It is applicable to tape in rollform when the user observes the precautions detailed withinthe procedure. The practice does not provide for a conclusionwithin itself, but is for use in conjunction
4、 with appearance orphysical property tests to follow the accelerated exposure.While this practice was developed using packaging type tapes,its use on other types of tape with similar construction isencouraged. It is not intended for use on electrical grade tapes(see Test Methods D1000).1.2 This stan
5、dard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 A
6、STM Standards:2D996 Terminology of Packaging and Distribution Environ-mentsD1000 Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applica-tionsD3330/D3330M Test Method for Peel Adhesion ofPressure-Sensitive TapeD3715/D3715M Practice for Quality Assurance o
7、fPressure-Sensitive TapesD4332 Practice for Conditioning Containers, Packages, orPackaging Components for Testing3. Terminology3.1 Terminology found in Terminology D996 shall apply.4. Summary of Practice4.1 The pressure-sensitive tape is exposed to an atmosphereof 80 % relative humidity at 150F (66C
8、) for a period of 96 h.Following a period for returning to a standard atmosphere, thetape is ready for a prescribed examination using a method suchas Test Methods D3330/D3330M.5. Significance and Use5.1 This practice accelerates the natural aging of pressure-sensitive tapes so that the response to t
9、he usual physicalproperty tests changes to the same extent as with an exposureto approximately two years of natural aging when comparedwith the response to tests before aging.5.1.1 Natural aging in this context means a continuousperiod of aging of tape in a closed fibreboard container (indarkness) i
10、n the variable climate of either the warm moistsouth, the warm dry southwest or the moderate midcontinent,USA.5.2 The extent of change for one physical property shouldbe expected to be different than for another property and sowould also relate to different natural aging time.5.3 An abnormal product
11、 lot may cause differences intesting response that throw off the expected time patterns.5.4 Appearance of normal tape product will usually changeonly slightly on two years natural aging. This acceleratedexposure usually produces an exaggerated change in appear-ance which would be seen under natural
12、conditions only inabnormal product.5.5 There is no present experience to relate this acceleratedexposure to responses of tape in applications where the tape isunder a use stress.6. Apparatus6.1 Humidity Vessel in Oven Procedure:6.1.1 Vessel, to contain a solution of ammonium sulphateand tape undergo
13、ing exposure. The vessel must meet thefollowing requirements:6.1.1.1 Vented to allow equilibrium with an opening not toexceed 0.01 mm.26.1.1.2 The air volume over the solution to be not more than10 % greater than the cube of the square root of the liquidsurface area.1This practice is under the juris
14、diction of ASTM Committee D10 on Packagingand is the direct responsibility of Subcommittee D10.14 on Tape and Labels.Current edition approved Sept. 1, 2011. Published November 2011. Originallyapproved in 1977. Last previous edition approved in 2006 as D3611 06. DOI:10.1520/D3611-06R11.2For reference
15、d ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
16、shohocken, PA 19428-2959, United States.6.1.1.3 The air depth of the vessel to the liquid surface to benot more than 10 % greater than the square root of the liquidsurface area.6.1.1.4 Adesiccator assembly with a perforated plate can bea suitable vessel.6.1.2 Oven, of the forced-convection type main
17、tained at amean of 66 6 2C (150 6 4F).6.2 Humidity chamber, to contain rolls of tape maintained ata mean of 66 6 2C (150 6 4F) and 80 6 5 % relativehumidity.7. Reagents (for Humidity Vessel in Oven procedure)7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise in
18、dicated, it is intended thatall reagents shall conform to the specification of the Committeeon Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to per
19、mit its use without lessening theaccuracy of the determination.7.2 Ammonium Sulfate (NH4)2SO4.7.3 Water, distilled or demineralized.7.4 The reagents of 7.2 and 7.3 are to be dissolved togetherin the proportion of 1 + 1 by weight. Use a volume (the unitswill be cubic centimetres) of water not less th
20、an that obtainedby multiplying 500 times 132 times the vessel air volume incubic metres. This gives 500 times the number of grams ofwater required to humidify the air volume to 80 % relativehumidity at 150F (66C) and should supply the moisturerequired to accommodate the absorption by the sample roll
21、s.This provides a saturated solution which will remain saturatedat 150F (66C). This solution within the closed vessel bothprovides and controls the moisture content (humidity) withinthe vessel.8. Sampling8.1 Sampling of material for this practice should be inaccordance with the requirements of the a
22、pplicable material orcommodity specification.8.2 Lacking the previously mentioned specification, sam-pling should be as required in the physical property methodapplicable to the testing to follow the exposure.8.3 When no other sampling requirement is applicable,sampling should be as set forth in Pra
23、ctice D3715/D3715M.9. Sample9.1 The sample should consist of rolls of tape.9.1.1 The quantity of tape in any sample roll need not bemore than necessary to supply the specimens for the physicalproperty tests to follow the exposure.9.1.2 No sample roll should be less than12 in. (12 mm) inwidth.9.1.3 S
24、ample rolls should be originally wound, not rewoundrolls.10. Procedure10.1 Humidity Vessel in Oven:10.1.1 Place the sample rolls above the solution in the vesselso that roll edges lie in a horizontal plane (parallel with theliquid surface). Include no more sample rolls than will displaceone fourth o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD361120062011STANDARDPRACTICEFORACCELERATEDAGINGOFPRESSURESENSITIVETAPES 胶带 加速 老化 标准 操作规程 PDF

链接地址:http://www.mydoc123.com/p-515101.html