ASTM D3576-2004 Standard Test Method for Cell Size of Rigid Cellular Plastics《测定硬质泡沫塑料微孔尺寸的标准试验方法》.pdf
《ASTM D3576-2004 Standard Test Method for Cell Size of Rigid Cellular Plastics《测定硬质泡沫塑料微孔尺寸的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3576-2004 Standard Test Method for Cell Size of Rigid Cellular Plastics《测定硬质泡沫塑料微孔尺寸的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3576 04Standard Test Method forCell Size of Rigid Cellular Plastics1This standard is issued under the fixed designation D 3576; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the appar-ent cell size of rigid cellular plastics by counting the number ofcell-wall intersections
3、 in a specified distance.1.2 Procedure A requires the preparation of a thin slice, notmore than one half the average cell diameter in thickness, thatis mechanically stable. For most rigid cellular plastics thislimits the test method to materials with an average cell size ofat least 0.2 mm.1.3 Proced
4、ure B is intended for use with materials whosefriable nature makes it difficult to obtain a thin slice forviewing.1.4 The values stated in SI units are to be regarded as thestandard. The values given in brackets are for information only.1.5 This standard does not purport to address all of thesafety
5、concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1The annex to ISO 2896 is technically equivalent to this testmethod.2. Re
6、ferenced Documents2.1 ASTM Standards:2D 883 Terminology Relating to PlasticsD 2842 Test Method for WaterAbsorption of Rigid CellularPlasticsD 2856 Test Method for Open-Cell Content of Rigid Cel-lular Plastics by the Air PycnometerE 691 Practice for Conducting an Interlaboratory Study toDetermine the
7、 Precision of a Test Method2.2 ISO Standard:ISO 2896 Cellular Plastics, RigidDetermination of WaterAbsorption33. Terminology3.1 Definitions:3.1.1 Definitions of terms applicable to this test method aregiven in Terminology D 883.4. Summary of Test Method4.1 Procedure A The cellular plastic specimen i
8、s cut tonot more than one half the average cell diameter in thicknesson a slicer and the shadowgraph is projected on a screen by theuse of a cell-size scale slide assembly and a projector. Theaverage chord length is obtained by counting the cells oncell-wall intersections and converting this value t
9、o average cellsize by mathematical derivation.4.2 Procedure B The cellular plastic specimen is sliced toprovide a smooth surface. The cell walls are accented by theuse of a marking pen. The average chord length is obtained bycounting the cell wall intersections and converting this value toaverage ce
10、ll size by mathematical derivation.5. Significance and Use5.1 Several physical properties of rigid cellular plastics aredependent on cell size and cell orientation. Measuring waterabsorption and open-cell content in accordance with TestMethod D 2842 and Test Method D 2856 requires knowledgeof surfac
11、e cell volume, which uses cell size values in thecalculations.5.2 This test method provides an apparent cell size becauseit assumes that there is no measurable edge to edge or top tobottom variation in average cell size and that the cell sizedistribution about the average cell size is normal. If the
12、 analystis concerned there may be significant variation in either theaverage cell size or the cell size distribution more detailedanalysis may be required.5.3 Before proceeding with this test method, referenceshould be made to the specification of the material being tested.Any test specimen preparat
13、ion, conditioning, dimensions, or1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.22 on Cellular Materials -Plastics and Elastomers.Current edition approved July 1, 2004. Published July 2004. Originally approvedin 1977.
14、 Last previous edition approved in 1998 as D 3576 - 98.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Avail
15、able from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.testing parameters
16、, or a combination thereof, covered in thematerials specification shall take precedence over those men-tioned in this test method. If there are no material specifica-tions, then the default conditions apply.6. Apparatus6.1 The apparatus required to perform the test as defined byProcedure A is listed
17、 as follows:6.1.1 Cell Size Specimen Slicer4Cutting blade apparatuscapable of slicing thin specimens (0.02 mm) for cell sizeviewing. Fig. 1 shows an acceptable alternative slicing appa-ratus.6.1.2 Cell Size ProjectorConventional 35-mm slide pro-jector that accepts standard 50 by 50-mm 2 by 2-in. sli
18、des.6.1.3 Cell Size Scale Slide Assembly, consisting of twopieces of slide glass5hinged by tape along one edge, betweenwhich a calibrated scale (30 mm in length) printed on a thinplastic sheet is placed (see Fig. 2).6.2 The apparatus required to perform the test as defined byProcedure B is listed as
19、 follows:6.2.1 Cell Size Specimen Slicer4Cutting blade apparatuscapable of providing a smooth surface.6.2.2 Optical Magnification System, capable of 5 to 253magnification with a calibrated scale of the appropriate length.6.2.3 Highlighting Market, that does not contain a solventwhich will attack the
20、 polymer system. The ink used shouldcontrast with the color of the foam.7. Sampling7.1 Generally one specimen is sufficient to determine theapparent cell size of a sample.7.2 The number of samples may be dictated by the end-usedata needed.8. Procedures8.1 Procedure A:8.1.1 Cut a specimen 50 by 50 mm
21、 by thickness 2 by 2 in.by thickness from the sample in the area to be tested.8.1.2 Prepare the cell size viewing specimen by cutting athin slice (less than monocellular) from one of the cut surfacesof the specimen. (Slice thickness should be as thin as practi-cable; so that a shadowgraph will not b
22、e occluded by overlap-ping cell walls. Optimum slice thickness will vary with theaverage cell size of the foam, with smaller cell foams requiringthinner slices.)NOTE 2One cell size measurement will provide a representativeapparent cell size for cellular plastics having symmetric cells of relativelyu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD35762004STANDARDTESTMETHODFORCELLSIZEOFRIGIDCELLULARPLASTICS 测定 硬质 泡沫塑料 微孔 尺寸 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515032.html