ASTM D2842-2012 Standard Test Method for Water Absorption of Rigid Cellular Plastics《硬质泡沫塑料吸水性的标准试验方法》.pdf
《ASTM D2842-2012 Standard Test Method for Water Absorption of Rigid Cellular Plastics《硬质泡沫塑料吸水性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2842-2012 Standard Test Method for Water Absorption of Rigid Cellular Plastics《硬质泡沫塑料吸水性的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2842 06 D2842 12Standard Test Method forWater Absorption of Rigid Cellular Plastics1This standard is issued under the fixed designation D2842; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers the determination of the w
3、ater absorption of rigid cellular plastics by measuring the change inbuoyant force resulting from immersion under a 5.1-cm (2-in.) head of water for the specified immersion period of 96 h.1.2 This test method describes two procedures that shall be used to measure the change in buoyant force. Procedu
4、re A shall beused for materials that either experience rapid water absorption or that show an increase in volume during the exposure period,or both. Materials that do not exhibit either of these characteristics shall be evaluated by Procedure B.1.3 For specific applications, immersion periods varyin
5、g from the normal 96-h test requirement shall be agreed upon betweenthe manufacturer and the purchaser.1.4 The values stated in SI units are to be regarded as the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibil
6、ityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 1This test method is equivalent to ISO 2896.NOTE 1This test method is equivalent to ISO 2896.2. Referenced Documents2.1 ASTM Standards:2E96/
7、E96ME96 Test Methods for Water Vapor Transmission of MaterialsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method2.2 ISO Standard:ISO 2896 Cellular Plastics, RigidDetermination of Water Absorption33. Terminology3.1 DefinitionsThere are no terms in this t
8、est method that are new or other than dictionary definitions.3.1 DefinitionsThere are no terms in this test method that are new or other than dictionary definitions.4. Summary of Test Method4.1 The buoyant force of an object less dense than water is equal to the weight of water it displaces when sub
9、merged, less thedry weight of the object. Water absorbed into the object lowers the buoyant force by increasing the weight of the sample. Byknowing the volume and initial dry weight of the sample, the initial buoyant force can be calculated or the initial buoyant forcecan be determined by direct mea
10、surement. The final buoyant force at the end of the immersion period is measured with anunderwater weighing assembly. The difference between the initial and final buoyant force is the weight of the water absorbed perunit of specimen volume.5. Significance and Use5.1 The purpose of this test method i
11、s to provide a means for comparing relative water absorption tendencies between differentcellular plastics. It is intended for use in specifications, product evaluation, and quality control. It is applicable to specific end-usedesign requirements only to the extent that the end-use conditions are si
12、milar to the immersion period (normally 96 h) and 5.1-cm2-in. head requirements of the test method.NOTE 2Studies by ASTM Subcommittee D20.22 show that some cellular plastics, particularly those with open cells or natural interstices, continueto absorb additional significant amounts of water beyond t
13、he 96-h immersion period. It was also found that water absorption of some cellular plasticsis significantly higher when exposed to a greater pressure head, as might be encountered in certain underwater installations.*A Summary of Changes section appears at the end of this standardCopyright ASTM Inte
14、rnational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 This test method provides a means for measuring absorption as a result of direct contact exposure to free water. Results bythis test method cannot be used to compare the resistance of cellular plastics
15、 to water vapor transmission and subsequentcondensation within the cells. To determine resistance to water vapor transmission, see Test Methods E96/E96ME96.5.3 Water absorption testing is subject to several important variables, which if not considered, prohibit sufficient agreementamong testing labo
16、ratories. Development of this test method has taken into account the most serious of the possible sources oferror.NOTE 3In some methods, an error is encountered due to a rapid absorption of water before an accurate initial weight can be obtained. This test methodaccounts for that potential error by
17、providing Procedure A for use with materials that behave in this manner. In this procedure the only submergedmeasurement required is a final weighing taken after the 96-h immersion period.NOTE 4The increase in volume that occurs with some foams when immersed is accounted for in Procedure A. This pro
18、cedure shouldshall be usedfor materials that exhibit this type of behavior. This is accounted for by basing all buoyant force calculations on the volume of the wet specimen at theconclusion of the immersion period.NOTE 5The problem of air bubbles clinging to the submerged specimen and affecting the
19、end result is minimized by specifying deaerated distilledwater.NOTE 6Surface cells opened during specimen preparation result in an error when calculating the apparent volume of the test specimen. The degreeof this error is a function of cell size. This test method accounts for this error in that all
20、 calculations are based on the true specimen volume. The truespecimen volume is determined in Procedure A as the measured volume minus the volume of surface cells opened by cutting. This correction is notrequired in Procedure B since the true specimen volume is determined by direct measurement.5.4 T
21、he volume error associated with surface cells opened during specimen preparation decreases as the cell size decreases. Thistest method provides the option to ignore this variable with cellular plastics estimated to that have an average cell diameter of 0.03cm or less. For cellular plastics having gr
22、eater than 0.03-cm average cell diameter and in all cases of dispute, measurement of cellsize shall be mandatory in determining the specimen volume.5.5 For most materials the size of the test specimens is small compared with the size of the products actually installed in thefield. If the surface-to-
23、volume ratios for the test specimens and the corresponding products are different, it is possible that the testresults may be are misleading.5.6 In most cases water retention is a secondary performance characteristic that has an influence on a primary characteristic,such as thermal performance, surf
24、ace accumulation of moisture, localized collection of electrolytes, dimensional stability, etc.5.7 Before proceeding with this test method, reference shall be made to the specification of the material being tested. Any testspecimen preparation, conditioning, dimensions, or testing parameters covered
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD28422012STANDARDTESTMETHODFORWATERABSORPTIONOFRIGIDCELLULARPLASTICS 硬质 泡沫塑料 吸水性 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-513609.html