ASTM D957-2006 Standard Practice for Determining Surface Temperature of Molds for Plastics《塑料生产用模型表面温度测定的标准实施规程》.pdf
《ASTM D957-2006 Standard Practice for Determining Surface Temperature of Molds for Plastics《塑料生产用模型表面温度测定的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D957-2006 Standard Practice for Determining Surface Temperature of Molds for Plastics《塑料生产用模型表面温度测定的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 957 06Standard Practice forDetermining Surface Temperature of Molds for Plastics1This standard is issued under the fixed designation D 957; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice is intended for determining the tempera-ture at a specified point or points on the surface of the cavityand base of a
3、mold for plastics. By determining the temperatureat as many points as deemed necessary, the overall temperaturecondition of the surface can be determined.1.2 The values stated in SI units are to be regarded asstandard. The values in brackets are given for information only.1.3 This standard does not
4、purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no similar ISO standard.2.
5、Summary of Practice2.1 With the use of a calibrated surface pyrometer, theoverall temperature condition of a mold for plastics can bedetermined by taking readings at a specified point or manypoints on the mold surface.3. Significance and Use3.1 The properties of molded parts and the ease of produc-i
6、ng satisfactory specimens are influenced by the temperature ofthe mold. It is desirable to know the actual mold temperaturewhich may be different from the mold temperature controlmedium.3.2 The user should be aware of temperature differencesacross the mold/thermocouple interface and at leads and sho
7、uldtake precautions to minimize such differences.4. Apparatus4.1 PyrometerA calibrated surface pyrometer traceable toa national metrology institution (NMI)2standard and accurateto within 61.5C shall be used.5. Procedure5.1 The size, shape, and contours of a mold will determinethe location and number
8、 of points at which temperaturereadings should be observed. Take temperature readings at asmany points as deemed necessary to determine the temperaturecondition of the mold surface. At a minimum, it is suggestedthat temperature be measured at the mold center, near the edge,and at least two different
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD9572006STANDARDPRACTICEFORDETERMININGSURFACETEMPERATUREOFMOLDSFORPLASTICS 塑料 生产 模型 表面温度 测定 标准 实施

链接地址:http://www.mydoc123.com/p-512588.html