ASTM D893-2005a Standard Test Method for Insolubles In Used Lubricating Oils《用过的润滑油中不溶物的标准试验方法》.pdf
《ASTM D893-2005a Standard Test Method for Insolubles In Used Lubricating Oils《用过的润滑油中不溶物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D893-2005a Standard Test Method for Insolubles In Used Lubricating Oils《用过的润滑油中不溶物的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 893 05aAn American National StandardStandard Test Method forInsolubles in Used Lubricating Oils1This standard is issued under the fixed designation D 893; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers the determin
3、ation of pentaneand toluene insolubles in used lubricating oils.1.2 Procedure A covers the determination of insolubleswithout the use of coagulant in the pentane. It provides anindication of the materials that can readily be separated fromthe oil-solvent mixtures by centrifuging.1.3 Procedure B cove
4、rs the determination of insolubles inoils containing detergents and employs a coagulant for both thepentane and toluene insolubles. In addition to the materialsseparated by using Procedure A, this coagulation procedureseparates some finely divided materials that may be suspendedin the oil.NOTE 1Resu
5、lts obtained by Procedures A and B should not becompared since they usually give different values. The same procedureshould be employed when comparing values obtained periodically on anoil in use or when comparing results determined by two or morelaboratories.1.4 The values stated in SI units are to
6、 be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and
7、 determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see Section 7 and 9.1.1.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 4177 Practice for Aut
8、omatic Sampling of Petroleum andPetroleum Products3. Terminology3.1 Definitions:3.1.1 coagulate, vto cause to become viscous or thick-ened into a coherent mass.3.1.2 coagulated pentane insolubles, nin used oil analy-sis, separated matter that results when a coagulant is added toa solution of used oi
9、l in pentane.3.1.2.1 DiscussionThe addition of a coagulant will aid inseparating finely divided materials that may have been held insuspension because of the dispersant characteristics of the oil.3.1.3 coagulated toluene insolubles, nin used oil analysis,coagulated and separated matter not soluble i
10、n pentane ortoluene.3.1.4 pentane insolubles, nin used oil analysis, separatedmatter resulting when a used oil is mixed with pentane.3.1.4.1 DiscussionIn this test method, the separation iseffected by centrifugation.3.1.5 toluene insolubles, nin used oil analysis, the portionof pentane insolubles no
11、t soluble in toluene.3.1.6 used oil, nany oil that has been in a piece ofequipment (for example, an engine, gearbox, transformer, orturbine), whether operated or not.3.1.6.1 DiscussionIn this test method, the oil can be anyoil that has been used for lubrication.3.2 Definitions of Terms Specific to T
12、his Standard:3.2.1 insoluble resins, nin used oil analysis, separatedmatter soluble in toluene but not pentane.3.2.1.1 DiscussionInsoluble resins can be calculated foreither Procedure A or B by subtracting the toluene insolublesfrom the pentane insolubles.4. Summary of Test Method4.1 Procedure AA re
13、presentative sample of used lubricat-ing oil is mixed with pentane and centrifuged. The oil solutionis decanted and the precipitate washed twice with pentane,dried, and weighed to give the pentane insolubles. For toluene1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Pr
14、oducts and Lubricants and is the direct responsibility of SubcommitteeD02.06 on Analysis of Lubricants.Current edition approved Nov. 1, 2005. Published November 2005. Originallyapproved in 1967. Last previous edition approved in 2005 as D 89305.2For referenced ASTM standards, visit the ASTM website,
15、 www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Dri
16、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.insolubles, a separate sample of the oil is mixed with pentaneand then centrifuged. The precipitate is washed twice withpentane, once with toluene-alcohol solution, and once withtoluene. The insoluble material is then dried and weighed
17、 togive the insolubles.4.2 Procedure BA representative sample of used lubricat-ing oil is mixed with pentane-coagulant solution and centri-fuged. The precipitate is washed twice with pentane, dried, andweighed to give coagulated pentane insolubles. For coagulatedtoluene insolubles a separate sample
18、of the oil is mixed withpentane-coagulant solution and centrifuged. The precipitate iswashed twice with pentane, once with toluene-alcohol solution,and once with toluene. The insoluble material is then dried andweighed to give coagulated toluene insolubles.5. Significance and Use5.1 Pentane insolubl
19、es can include oil-insoluble materialsand some oil-insoluble resinous matter originating from oil oradditive degradation, or both.5.2 Toluene insoluble materials can come from (1) externalcontamination, (2) fuel carbon and highly carbonized materialsfrom degradation of fuel, oil, and additives, or (
20、3) engine wearand corrosion materials.5.3 A significant change in pentane insolubles, tolueneinsolubles (with or without coagulant), and insoluble resinsindicates a change in oil which could lead to lubrication systemproblems.5.4 Insolubles measured can also assist in evaluating theperformance chara
21、cteristics of a used oil or in determining thecause of equipment failure.6. Apparatus6.1 Centrifuge Tube, cone-shaped, conforming to the di-mensions given in Fig. 1, and made of thoroughly annealedglass. The graduations, numbered as shown in Fig. 1, shall beclear and distinct and the mouth constrict
22、ed in shape forclosure with a cork. Scale error tolerances and smallestgraduations between various calibration marks are given inTable 1 and apply to calibrations made with air-free water at20C.6.2 Centrifuge, meeting all safety requirements for normaluse and capable of whirling two or more filled c
23、entrifuge tubesat a speed that can be controlled to give a relative centrifugalforce (rcf) between 600 and 700 at the tips of the tubes. Therevolving head, trunnion rings, and trunnion cups, includingthe rubber cushion, shall be soundly constructed to withstandthe maximum centrifugal force capable o
24、f being delivered bythe power source. The trunnion cups and cushions shall firmlysupport the tubes when the centrifuge is in motion. Thecentrifuge shall be enclosed by a metal shield or case strongenough to eliminate danger if any breakage occurs. Calculatethe speed of the rotating head as follows:S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD8932005ASTANDARDTESTMETHODFORINSOLUBLESINUSEDLUBRICATINGOILS 润滑油 中不溶物 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-512428.html