ASTM D2161-2010(2016) Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity《运动粘度换算为赛波特通用粘度或赛波特重油粘度的标准实施规程》.pdf
《ASTM D2161-2010(2016) Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity《运动粘度换算为赛波特通用粘度或赛波特重油粘度的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2161-2010(2016) Standard Practice for Conversion of Kinematic Viscosity to Saybolt Universal Viscosity or to Saybolt Furol Viscosity《运动粘度换算为赛波特通用粘度或赛波特重油粘度的标准实施规程》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2161 10 (Reapproved 2016)Standard Practice forConversion of Kinematic Viscosity to Saybolt UniversalViscosity or to Saybolt Furol Viscosity1This standard is issued under the fixed designation D2161; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1.
3、 Scope1.1 This practice2covers the conversion tables and equa-tions for converting kinematic viscosity in mm2/s at anytemperature to Saybolt Universal viscosity in Saybolt Univer-sal seconds (SUS) at the same temperature and for convertingkinematic viscosity in mm2/s at 122 F and 210 F (50 C and98.9
4、 C) to Saybolt Furol viscosity in Saybolt Furol seconds(SFS) at the same temperatures. Kinematic viscosity values arebased on water being 1.0034 mm2/s (cSt) at 68 F (20 C).NOTE 1Afundamental and preferred method for measuring kinematicviscosity is by use of kinematic viscometers as outlined in Test
5、MethodD445. It is recommended that kinematic viscosity be reported in millime-tres squared per second, instead of Saybolt Universal Seconds (SUS) orSaybolt Furol Seconds (SFS). This method is being retained for thepurpose of calculation of kinematic viscosities from SUS and SFS datathat appear in pa
6、st literature. One millimetre squared per second (mm2/s)equals one centistoke (cSt), which is another unit commonly found inolder literature.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are provided forreference information purposes only. The S
7、I unit of kinematicviscosity is mm2/s.1.2.1 ExceptionFahrenheit temperature units are used inthis practice because they are accepted by industry for the typeof legacy conversions described in this practice.1.3 This standard does not purport to address all of thesafety concerns, if any, associated wi
8、th its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D445 Test Method for Kinematic Viscosity of Transparentand Opaque
9、Liquids (and Calculation of Dynamic Viscos-ity)D2270 Practice for Calculating Viscosity Index from Kine-matic Viscosity at 40 C and 100 C2.2 ASTM Adjunct:4ADJD2161 Viscosity Extrapolation Tables to Zero DegreesFahrenheit (SSU)3. Summary of Practice3.1 The Saybolt Universal viscosity equivalent to a
10、givenkinematic viscosity varies with the temperature at which thedetermination is made. The basic conversion values are thosegiven in Table 1 for 100 F. The Saybolt Universal viscosityequivalent to a given kinematic viscosity at any temperaturemay be calculated as described in 4.3. Equivalent values
11、 at210 F are given in Table 1 for convenience.3.2 The Saybolt Furol viscosity equivalents are tabulated inTable 3 for temperatures of 122 F and 210 F only.3.3 Examples for using the tables are given in Appendix X1.4. Significance and Use4.1 At one time the petroleum industry relied on measuringkinem
12、atic viscosity by means of the Saybolt viscometer, andexpressing kinematic viscosity in units of Saybolt UniversalSeconds (SUS) and Saybolt Furol Seconds (SFS). This practiceis now obsolete in the petroleum industry.4.2 This practice establishes the official equations relatingSUS and SFS to the SI k
13、inematic viscosity units, mm2/s.1This practice is under the jurisdiction of ASTM Committee D02 on PetroleumProducts, Liquid Fuels, and Lubricants and is the direct responsibility of Subcom-mittee D02.07 on Flow Properties.Current edition approved July 1, 2016. Published July 2016. Originally approve
14、din 1963, replacing former D446 and D666. Last previous edition approved in 2010as D2161 101. DOI: 10.1520/D2161-10R16.2This practice, together with Practice D2270, replaces Compilation of ASTMViscosity Tables for Kinematic Viscosity Conversions.3For referenced ASTM standards, visit the ASTM website
15、, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from ASTM International Headquarters. Order Adjunct No.ADJD2161. Original adjunct produced in 1998.*A Su
16、mmary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 This practice allows for the conversion between SUSand SFS units and SI units of kinematic viscosity.5. Procedure for Conv
17、ersion to Saybolt UniversalViscosity5.1 Convert kinematic viscosities between 1.81 mm2/s and500 mm2/s (cSt) at 100 F, and between 1.77 mm2/s and139.8 mm2/s (cSt) at 210 F, to equivalent Saybolt Universalseconds directly from Table 1 (see Appendix X1, Example 1).NOTE 2Obtain viscosities not listed, b
18、ut which are within the rangegiven in Table 1, by linear interpolation (see Appendix X1, Example 2).5.2 Convert kinematic viscosities greater than the upperlimits of Table 1 at temperatures of 100 F and 210 F toSaybolt Universal viscosities as follows (see Appendix X1,Example 3):Saybolt Universal se
19、conds 5 centistokes 3B (1)where B = 4.632 at 100 F or 4.664 at 210 F.5.3 At temperatures other than 100 F or 210 F, convertkinematic viscosities to Saybolt Universal viscosities as fol-lows4(see Appendix X1, Example 4):Ut5 U100F110.000061t 2 100! (2)where:Ut= Saybolt Universal viscosity at tF, andU1
20、00F= Saybolt Universal viscosity at 100F in SayboltUniversal seconds equivalent to kinematic viscos-ity in centistokes at tF, from Table 1.NOTE 3The multipliers for Saybolt Universal seconds in Eq 2 aregiven as Factor A in Table 2 for a range of temperatures.5.4 Since the relationship between Saybol
21、t and kinematicviscosities is linear above 75 mm2/s (cSt), kinematic viscositiesabove this limit may be converted to Saybolt Universalviscosities at any temperature between 0 F and 350 F by useof Eq 1 (4.2), selecting the proper factor for B from Table 2(see Appendix X1, Example 5).6. Procedure for
22、Conversion to Saybolt Furol Viscosity6.1 Convert kinematic viscosities between 48 mm2/s to1300 mm2/s (cSt) at 122 F, and between 50 mm2/s and1300 mm2/s (cSt) at 210 F, to equivalent Saybolt Furol sec-onds directly from Table 3 (see Appendix X1, Examples 6 and7).NOTE 4Viscosities not listed, but whic
23、h are within the range given inTable 3, may be obtained by linear interpolation (see Appendix X1,Example 8).6.2 Convert kinematic viscosities above 1300 cSt to equiva-lent Saybolt Furol seconds by use of the following equations(see Appendix X1, Example 9):Saybolt Furol seconds at 122F (3)5 0.4717 3m
24、m2/s cSt! at 122FSaybolt Furol seconds at 210F (4)5 0.4792 3mm2/s cSt! at 210F7. Procedure for Computer Calculation7.1 Table 1 and Table 3 were computed by fitting a smoothcurve to the original experimental data points. The derivedequations are given as follows for the convenience of thosewho wish t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD216120102016STANDARDPRACTICEFORCONVERSIONOFKINEMATICVISCOSITYTOSAYBOLTUNIVERSALVISCOSITYORTOSAYBOLTFUROLVISCOSITY

链接地址:http://www.mydoc123.com/p-511110.html