ASTM D1708-2010 Standard Test Method for Tensile Properties of Plastics by Use of Microtensile Specimens《使用微型抗拉试样测定塑料的抗拉特性的标准试验方法》.pdf
《ASTM D1708-2010 Standard Test Method for Tensile Properties of Plastics by Use of Microtensile Specimens《使用微型抗拉试样测定塑料的抗拉特性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1708-2010 Standard Test Method for Tensile Properties of Plastics by Use of Microtensile Specimens《使用微型抗拉试样测定塑料的抗拉特性的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1708 10Standard Test Method forTensile Properties of Plastics by Use of MicrotensileSpecimens1This standard is issued under the fixed designation D1708; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers certain material
3、 specificationsfor which a history of data has been obtained using the standardmicrotensile specimen. The specimen geometry has beenchanged to be equivalent to that of ISO 12086-2:1995.Ingeneral, this test method is superseded for general use by eitherTest Methods D882 or Test Method D638. The very
4、small TypeV specimen in Test Method D638 is the recommended speci-men when limited amounts of material are available.1.2 This test method covers the determination of the com-parative tensile strength and elongation properties of plastics inthe form of standard microtensile test specimens when tested
5、under defined conditions of pretreatment, temperature, humid-ity, and testing machine speed. It can be used for specimens ofany thickness up to 3.2 mm (18 in.), including thin films.1.3 This test method cannot be used for the determination ofmodulus of elasticity. For the determination of modulus, s
6、eeTest Method D638 or Test Methods D882.1.4 Test data obtained by this test method are relevant andappropriate for use in engineering design.1.5 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to
7、address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standa
8、rd.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD638 Test Method for Tensile Properties of PlasticsD882 Test Method for Tensile Properties of Thin PlasticSheetingD883 Terminology Relating to PlasticsD4000 Classification System for Specifying Plastic M
9、ateri-alsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standard:ISO 12086-2:1995 PlasticsFluoropolymer Dispersion,Moulding, and Extrusion MaterialsPart 2 Preparation ofTest Specimens and Determination of Properties33. Terminology3.1 Definitio
10、ns: Definitions of terms applying to this testmethod appear in Terminology D883 and Test Method D638,Annex A2.4. Significance and Use4.1 This test method provides data for quality control andacceptance or rejection under specifications.4.2 Before proceeding with this test method, referenceshould be
11、made to the ASTM specification of the materialbeing tested. Any test specimen preparation, conditioning,dimensions, or testing parameters, or combination thereof,covered in the materials specification shall take precedenceover those mentioned in this test method. If there are nomaterial specificatio
12、ns, then the default conditions hereinapply. Table 1 of Classification System D4000 lists the ASTMmaterials standards that currently exist.5. Apparatus5.1 The apparatus shall be as specified in Test MethodD638, with the following exceptions:5.1.1 GripsSerrated grips faces should be used with care,si
13、nce yielding or tearing at the grips may interfere withmeasurement of elongation even when the specimen breaks inthe reduced section. Grips with rubber coated faces arerecommended for thin specimens. Care should be taken when1This test method is under the jurisdiction of ASTM Committee D20 on Plasti
14、csand is the direct responsibility of Subcommittee D20.10 on Mechanical Properties.Current edition approved April 1, 2010. Published April 2010. Originallyapproved in 1959. Last previous edition approved in 2006 as D1708 - 06a. DOI:10.1520/D1708-10.2For referenced ASTM standards, visit the ASTM webs
15、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http
16、:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.selecting and using self tightening grips. Those which move asthey tighten and result in a change in the
17、 grip separationbetween upper and lower grips are not satisfactory for this testmethod. If the specimen tab is not long enough to prevent thegrip faces from cocking, shims should be inserted to providemore uniform clamping.5.1.2 Drive MechanismThe velocity of the drive mecha-nism shall be regulated
18、as specified in Section 8.5.1.3 The fixed and movable members, drive mechanism,and grips should be constructed of such materials and in suchproportions that, after grip slack is taken up, the total elasticlongitudinal deformation of the system constituted by theseparts does not exceed 1 % of the tot
19、al longitudinal deformationbetween the grips at any time during the test. If this is notpossible, appropriate corrections shall be made in the calcula-tion of strain values.5.1.4 Extension IndicatorThe extension indicator shall becapable of determining the distance between grips at any timeduring th
20、e test. The instrument shall be essentially free ofinertia lag at the specified speed of testing, and shall beaccurate to 61 % of extension or better.NOTE 2It is desirable that the load indicator and the extensionindicator be combined into one instrument, which automatically recordsthe load as a fun
21、ction of the extension or as a function of time. In the lattercase, the conversion to a load-extension record can readily be madebecause extension is proportional to time after the take-up of the initialgrip slack.5.1.5 MicrometersMicrometers shall read to 0.0025 mm(0.0001 in.) or less.6. Test Speci
22、mens6.1 Microtensile test specimens shall conform to the dimen-sions shown in Fig. 1. This specimen shall be prepared bydie-cutting or machining from sheet, plate, slab, or finishedarticle. Dimensions of a die suitable for preparing die-cutspecimens are also shown in Fig. 1. Specimens may also bepre
23、pared by injection molding or compression molding.6.2 All surfaces of the specimen shall be free of visibleflaws, scratches, or imperfections. Marks left by coarse ma-chining operations shall be carefully removed with a fine file orabrasive, and the filed surfaces shall then be smoothed withabrasive
24、 paper (No. 00 or finer). The finishing sanding strokesshall be made in the direction parallel to the long axis of thetest specimen.NOTE 3Tabs shown in Fig. 1 are minimum size for adequate gripping.Shims may be required with thicker specimens to keep grips fromcocking. Handling is facilitated and gr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD17082010STANDARDTESTMETHODFORTENSILEPROPERTIESOFPLASTICSBYUSEOFMICROTENSILESPECIMENS 使用 微型 试样 测定

链接地址:http://www.mydoc123.com/p-510323.html