1、Designation: D 1394 76 (Reapproved 2009)Standard Test Methods forChemical Analysis of White Titanium Pigments1This standard is issued under the fixed designation D 1394; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover procedures fo
3、r the chemicalanalysis of white titanium dioxide pigments.1.2 The analytical procedures appear in the following order:SectionsPreparation of Sample 4Qualitative Analysis 5 and 6Moisture 7Total Titanium:Jones Reductor Method 8-12Aluminum Reduction Method 13-17Aluminum Oxide 18-22Silica 23-291.3 The v
4、alues stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate
5、safety and health practices and determine the applica-bility of regulatory limitations prior to use. A specific hazardstatement is given in Section 19.2. Referenced Documents2.1 ASTM Standards:2D 280 Test Methods for Hygroscopic Moisture (and OtherMatter Volatile Under the Test Conditions) in Pigmen
6、tsD 1193 Specification for Reagent WaterE50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated Materials3. Reagents3.1 Purity of ReagentReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall r
7、eagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening
8、theaccuracy of the determination.3.2 Unless otherwise indicated, references to water shall beunderstood to mean reagent water conforming to Type IV ofSpecification D 1193.4. Preparation of Sample4.1 The sample shall, in all cases, be thoroughly mixed andcomminuted before taking portions for analysis
9、.QUALITATIVE ANALYSIS5. Reagents5.1 Ammonium Hydroxide (sp gr 0.90)Concentrated am-monium hydroxide (NH4OH).5.2 Ammonium Sulfate(NH4)2SO4).5.3 Hydrochloric Acid (sp gr 1.19)Concentrated hydro-chloric acid (HCl).5.4 Hydrogen Peroxide (30 %)Concentrated hydrogenperoxide (H2O2).5.5 Hydrogen Sulfide (H2
10、S).5.6 Sulfuric Acid (sp gr 1.84)Concentrated sulfuric acid(H2SO4).5.7 Sulfuric Acid (1+19)Carefully mix 1 volume ofH2SO4(sp gr 1.84) with 19 volumes of water.5.8 Tartaric Acid.5.9 Tin or Zinc Metal.6. Procedure6.1 Place about 0.5 g of the sample in a 250-mL glassbeaker,4and add 20 mL of H2SO4(sp gr
11、 1.84) and 7 to8gof(NH4)2SO4. Mix well and boil for a few minutes. The sampleshould go completely into solution; a residue denotes the1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Sub
12、committee D01.31 on Pigment Specifications.Current edition approved June 1, 2009. Published June 2009. Originallyapproved in 1956. Last previous edition approved in 2003 as D 1394 76 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at servi
13、ceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the America
14、n Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.4Borosilicate glass has been found satisfactory for this purpose.1Copyright ASTM Interna
15、tional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.presence of silicon dioxide (SiO2) or siliceous matter. Cool thesolution, dilute with 100 mL of water, heat to boiling, let settle,filter, wash with hot H2SO4(1+19) until free of titanium, andtest the residue
16、 for lead, etc.6.2 Test the filtrate for calcium, zinc, iron, chromium, etc.,by the regular methods of qualitative analysis.5For the irondetermination add to a portion of the filtrate5goftartaric acid,render slightly ammoniacal, pass in H2S in excess, and digeston a steam bath. No precipitate after
17、30 min indicates theabsence of iron, nickel, cobalt, lead, copper, etc. A blackprecipitate readily soluble in dilute HCl denotes iron. Fortitanium, test a small portion of the original filtrate with H2O2(a clear yellow-orange color should result) and another portionwith metallic tin or zinc (a pale
18、blue to violet coloration shouldresult). Negative results should be shown for sulfide, carbon-ate, or appreciable water-soluble matter.MOISTURE7. Procedure7.1 Determine moisture and other volatile matter in accor-dance with Test Method A of Test Methods D 280.TOTAL TITANIUM BY THE JONES REDUCTORMETH
19、OD8. Scope8.1 This method gives results similar to those obtained withthe Aluminum Reduction Method, Sections 13-17.9. Apparatus9.1 Jones Reductor6having a zinc column at least 450 mmin length, and 19 mm in diameter (Fig. 1 and Fig. 2). Thefiltering pad must be tight enough to hold all the particles
20、 ofamalgamated zinc resting on it, and may be made of asbestosor, preferably, glass-wool supported by platinum gauze or aperforated porcelain plate. Use the least amount (0.1 to 1.0 %)of mercury that will enable satisfactory control of hydrogenevolution, since heavy amalgamation tends to reduce the
21、rateof reaction. Prepare the amalgam by washing 20-mesh zinc for1 min in enough 1 N HCl to cover it, adding the proper amountof 0.25 M mercuric nitrate or chloride solution, and stirringrapidly for 3 min. Decant the solution and wash the amalgamwith water and store under water to which a few drops o
22、f HClhave been added. After using, keep the reductor filled withwater when not in use, in order that basic salts will not beformed and clog it.10. Reagents10.1 Ammonium Hydroxide (sp gr 0.90)Concentrated am-monium hydroxide (NH4OH).10.2 Ammonium Sulfate (NH4)2SO4).10.3 Carbon Steel or IronPure iron
23、or plain carbon steel.10.4 Ferric Sulfate Solution (1 mL = 0.02 g Fe)Dissolve20 g of iron or carbon steel in a slight excess of HCl, oxidizewith approximately 12 mL of HNO3, add about 80 mL ofH2SO4, and heat to dense white fumes. Cool, dilute with waterto 1 L, digest on a steam bath until sulfates a
24、re dissolved, andfilter if necessary. To oxidize any ferrous iron that may bepresent, add 0.1 N KMnO4solution until a faint pink colorpersists for 5 min. Ferric ammonium sulfate (FeNH4(SO4)212H2O) may also be used to prepare this solution (See 15.4).10.5 Hydrochloric Acid (sp gr 1.19)Concentrated hy
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD139419762009STANDARDTESTMETHODSFORCHEMICALANALYSISOFWHITETITANIUMPIGMENTS 钛白 颜料 化学分析 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509729.html