ASTM C867-1994(2007) Standard Test Method for Soluble Sulfate in Ceramic Whiteware Clays (Photometric Method)《卫生陶瓷粘土中可溶性硫酸盐的标准试验方法(光度法)》.pdf
《ASTM C867-1994(2007) Standard Test Method for Soluble Sulfate in Ceramic Whiteware Clays (Photometric Method)《卫生陶瓷粘土中可溶性硫酸盐的标准试验方法(光度法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C867-1994(2007) Standard Test Method for Soluble Sulfate in Ceramic Whiteware Clays (Photometric Method)《卫生陶瓷粘土中可溶性硫酸盐的标准试验方法(光度法)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 867 94 (Reapproved 2007)Standard Test Method forSoluble Sulfate in Ceramic Whiteware Clays (PhotometricMethod)1This standard is issued under the fixed designation C 867; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of solublesulfate ions present in water or a filtrate by mean
3、s of aphotometer measuring the turbidity of precipitated bariumsulfate. A method of standardizing the photometer for this testmethod is also given.1.2 Soluble sulfate ions may be removed from clays orclay-water slurries by leaching with water during mixing andsubsequent filter pressing. To remove al
4、l the sulfate ions wouldrequire an impractical number of washings; therefore, this testmethod should be considered a control test and not a quanti-tative analysis for SO4ions.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibi
5、lity of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 324 Test Method for Free Moisture in Ceramic Whitew-are ClaysD 1193 Specification for Reagent W
6、ater2.2 American Chemical Society Document:Specification for Reagent Chemicals33. Apparatus3.1 Balance, accurate to 0.0001 g.3.2 High-Speed Mixer.3.3 Filter Press, capable of operating at 690 kPa (100 psi).3.4 Glass Beakers, Erlenmeyer Flasks.3.5 Transfer Pipets.3.6 Spectrophotometer and accessories
7、.3.7 Measuring Spoon, to hold approximately 0.2 g of BaCl2or THQ Cup.3.8 Other usual laboratory equipment, including timers, etc.4. Reagents4.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specif
8、ications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades may beused, provided it is first ascertained that the regent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.4.2
9、 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean Type IV Grade reagentwater as defined in Specification D 1193.4.3 Barium Chloride (BaCl2H2O) crystals, 20 to 30 mesh.4.4 Salt-Acid Reagent However, it can be prepared from:23.6 ml HCl, 253.0 gm NaCl, 976.4 ml
10、distilled water. Thissolution should be stored in an automatic pipettor for accuratemeasurement.4.5 Glycerine Reagenta mixture of equal volumes of c. p.glycerine and reagent grade water or it may be purchased froma laboratory supply house. This solution should be stored in anautomatic pipettor for a
11、ccurate measurement.4.6 Standard Sulfate Solutiona solution of c. p. sodiumsulfate in reagent grade water at a concentration which containsexactly 100 ppm of sulfate ion.1This test method is under the jurisdiction ofASTM Committee C21 on CeramicWhitewares and Related Products and is the direct respo
12、nsibility of SubcommitteeC21.04 on Raw Materials.Current edition approved May 1, 2007. Published May 2007. Originallyapproved in 1977. Last previous edition approved in 2001 as C 867 94 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at se
13、rviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Chemical Society, 1155 16th Street, NW, Washing-ton, DC 20036.4Reagent Chemicals, American Chemical Society Specifications , AmericanChemical S
14、ociety, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville
15、,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Standardization of Apparatus5.1 It should be noted that the instrument requires about 30min to warm up. Keep a blank cell in the instrument when asample is not in the holder. For
16、 SO4determination, the filterwavelength should be set at 550 nm.5.2 Using the appropriate pipettes, measure 25 ml of thestandard 100 ppm solution into a 125 ml Erlenmeyer flask.Add5 ml of glycerine reagent and 2.5 ml of salt-acid reagent andstir thoroughly.5.3 Fill a clean transmission cell with the
17、 prepared solution.Be sure to wipe off any droplets of water or solution on theoutside of the cell since this may interfere with the readings.5.4 Insert the cell into the cell holder. Put the 550 nm filterin place and adjust the transmission to read 100.0 percent.5.5 Pour the contents of the cell ba
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC86719942007STANDARDTESTMETHODFORSOLUBLESULFATEINCERAMICWHITEWARECLAYSPHOTOMETRICMETHOD 卫生陶瓷 粘土 可溶性

链接地址:http://www.mydoc123.com/p-508590.html