1、Designation: C 725 90 (Reapproved 2003)e1Standard Specification forSemidense Mineral Fiber Siding1This standard is issued under the fixed designation C 725; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTEAsbestos warning was moved from 9.2.1.1 to 1.3 in Septem
3、ber 2004.1. Scope1.1 This specification covers semidense mineral fiber siding(shingles, clapboards, and sheets) designed to provide protec-tion for the weather-exposed sidewall surfaces of buildings.These sidings are nailable with or without prepunched holes.1.2 The values stated in SI units are to
4、be regarded as thestandard. The values stated in parentheses are provided forinformation only.1.3 WarningBreathing of asbestos dust is hazardous.Asbestos and asbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions,
5、when working with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysoltile asbestos, refer to “Safe Useof Chrysotile Asbestos: A Manual on Preventive and ControlMeasures.”21.4 The following precautionary caveat pertains only to thetest method portion,
6、 Section 9, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions
7、prior to use. For a specific hazard warning, see 1.3.2. Referenced Documents2.1 ASTM Standards:3C 460 Terminology for Asbestos-Cement4D 1037 Test Methods of Evaluating the Properties of Wood-Base Fiber and Particle Panel Materials2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Age
8、ncies)52.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage53. Classification3.1 Semidense mineral fiber siding shall be one of thefollowing types, as specified:3.1.1 Type I, ShinglesUniform thickness, rectangular inshape, and having wavy, random, thatched, straight or irregularbutts.
9、Shingles are limited to 1.22 m (48 in.) in maximumlength and 0.41 m (16 in.) in maximum width. Shingles areapplied in horizontal lapped courses. The specified width isgenerally less than the specified length.3.1.2 Type II, ClapboardsUniform thickness, rectangularin shape and in lengths from 1.24 m (
10、49 in.) to 3.66 m (144 in.)and widths up to 0.41 m (16 in.). The clapboards are applied inhorizontal lapped courses.3.1.3 Type III, SheetsUniform thickness, rectangular inshape and usually in 1.22-m (48-in.) widths and 1.22 to 3.66-m(48 to 144-in.) lengths. The sheets are generally appliedvertically
11、 to sheathed or unsheathed sidewalls.4. Materials and Manufacture4.1 Semidense mineral fiber sidings are composed of acombination of asbestos fibers, portland cement or portlandblast-furnace slag cement and mineral fillers, with or withoutthe addition of organic fibers, curing agents, water repellen
12、tsubstances, coatings, or pigments, formed under pressure andcured to meet the physical requirements of this specification.5. Physical Properties5.1 Flexural StrengthThe average breaking load obtainedby loading equally and simultaneously at both one-third pointsof the span shall not be less than as
13、shown in Table 1.1This specification is under the jurisdiction of ASTM Committee C17 onFiber-Cement Products and is the direct responsibility of Subcommittee C17.03 onAsbestos-Cement Products.Current edition approved Jan. 10, 2003. Published July 2003. Originallyapproved in 1972. Last previous editi
14、on approved in 1998 as C 725 90(1998).2Available from The Asbestos Institute, http:/ referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
15、onthe ASTM website.4Withdrawn.5Available from Standardization Documents, Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 DeflectionAt the u
16、ltimate breaking load obtained byloading equally and simultaneously at both one-third points ofthe span shall not be less than as shown in Table 1.5.3 Water-Absorption SwellingThe average thickness in-crease resulting from water absorption shall not exceed 2 %.5.4 Product DurabilityThe product shall
17、 withstand sixcomplete cycles of accelerated aging conducted in accordancewith Section 120 of Test Methods D 1037, and exhibit novisible delamination. The average breaking load of the driedtest specimens after cycling shall not show a decrease instrength of more than 10 % when compared with the corr
18、e-sponding values obtained from tests made on companioncontrol specimens tested in accordance with 5.1.5.5 DensityThe average density as measured in the drystate shall be not less than 800 kg/m3(50 lb/ft3).5.6 Refer to Terminology C 460 for terminology.6. Dimensions, Mass, and Permissible Variations
19、6.1 Siding covered by this specification shall conform to thedimensions prescribed in Table 2.6.2 TolerancesThe permissible variation from the nomi-nal width or length shall be 3.2 mm (618 in.), and theminimum thickness shall be 7.5 mm (0.30 in.) for nominal38-in. thick product and 6.1 mm (0.24 in.)
20、 for nominal14-in.thick product as measured after conditioning for a minimum of24hat706 3F (216 1.6C) and 50 % relative humidity. Thedeviation from squareness shall not exceed 1.3 mm/m (164in./ft) of width or length when measured with a feeler gage and0.61-m (2-ft) metal carpenters square.7. Workman
21、ship, Finish, and Appearance7.1 WorkmanshipThe product shall be free of defects thatwill impair appearance, erection, or serviceability.7.2 Color and FinishThe exposed surface of the sidingmay be smooth, granuled, or otherwise textured as specified.The natural color is a light tan or gray and the su
22、rface may beuncoated, factory primed, or prefinished, as specified.7.3 Holes for Nails and Fasteners:7.3.1 Type I, ShinglesUnless otherwise specified, shinglesshall be furnished with nail holes so placed as to provide aminimum top lap of 25.4 mm (1 in.).7.3.2 Type II, ClapboardsUnless otherwise spec
23、ified,clapboards shall be supplied without nail holes. These productsare nailable and intended to be applied to provide a minimumtop lap of 25.4 mm (1 in.).7.3.3 Type III, SheetsSheets are supplied without nailholes, and are normally applied vertically in accordance withaccepted practices.8. Nails8.
24、1 Nail MaterialsAll nails shall be of nonstaining,corrosion-resistant material.8.2 Type I ProductThe face nails for Type I shingles shallbe furnished by the shingle manufacturer and have shankssized to enter the nail holes where provided in the units. Thenails shall be long enough to hold the siding
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC72519902003E1STANDARDSPECIFICATIONFORSEMIDENSEMINERALFIBERSIDING 密实 矿物纤维 板壁 规格 PDF

链接地址:http://www.mydoc123.com/p-508130.html