《ASTM C506M-2011 Standard Specification for Reinforced Concrete Arch Culvert Storm Drain and Sewer Pipe (Metric)《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格(公制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C506M-2011 Standard Specification for Reinforced Concrete Arch Culvert Storm Drain and Sewer Pipe (Metric)《钢筋混凝土制拱形涵洞 雨水道和污水管的标准规格(公制)》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C506M 11Standard Specification forReinforced Concrete Arch Culvert, Storm Drain, and SewerPipe (Metric)1This standard is issued under the fixed designation C506M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers reinfo
3、rced arch-shaped con-crete pipe to be used for the conveyance of sewage, industrialwastes, storm water, and for the construction of culverts.1.2 This specification is the SI companion to SpecificationC506.NOTE 1This specification is a manufacturing and purchase specifica-tion only, and does not incl
4、ude requirements for bedding, backfill, or therelationship between field load condition and the strength classification ofpipe. However, experience has shown that the successful performance ofthis product depends upon the proper selection of the class of pipe, typeof bedding and backfill, and care t
5、hat the installation conforms to theconstruction specifications. The owner of the reinforced concrete pipespecified herein is cautioned that he must correlate the field requirementswith the class of pipe specified and provide inspection at the constructionsite.2. Referenced Documents2.1 ASTM Standar
6、ds:2A36/A36M Specification for Carbon Structural SteelA82/A82M Specification for Steel Wire, Plain, for ConcreteReinforcementA185/A185M Specification for Steel Welded Wire Rein-forcement, Plain, for ConcreteA496/A496M Specification for Steel Wire, Deformed, forConcrete ReinforcementA497/A497M Specif
7、ication for Steel Welded Wire Rein-forcement, Deformed, for ConcreteA615/A615M Specification for Deformed and PlainCarbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Low-Alloy Steel Deformedand Plain Bars for Concrete ReinforcementC33 Specification for Concrete AggregatesC150 S
8、pecification for Portland CementC260 Specification for Air-Entraining Admixtures for Con-creteC309 Specification for Liquid Membrane-Forming Com-pounds for Curing ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC497M Test Methods for Concrete Pipe, Manhole Sections,or Tile Metric
9、C595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC822 Terminology Relating to Concrete Pipe and RelatedProductsC989 Specification for Slag Cement for Use in Concreteand MortarsC1017/C1017M Specification for Che
10、mical Admixtures forUse in Producing Flowing ConcreteC1116 Specification for Fiber-Reinforced Concrete andShotcrete3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C822.4. Classification4.1 Pipe manufactured according to this specification shallbe of
11、three classes identified as ClassA-II,A-III, andA-IV. Thestrength requirements are prescribed in Table 1.5. Basis of Acceptance5.1 Unless otherwise designated by the owner at the time of,or before placing an order, there are two separate and alterna-tive bases of acceptance. Independent of the metho
12、d ofacceptance, the pipe shall be designed to meet both the 0.01-in.crack and ultimate strength requirements.5.1.1 Acceptance on Basis of Plant Load Bearing Tests,Material Tests, and Inspection of Manufactured Pipe for VisualDefects and ImperfectionsAcceptability of the pipe in alldiameters and clas
13、ses produced in accordance with 7.1 or 7.2shall be determined by the results of the three-edge-bearing1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.02 onReinforced Sewer and Culvert Pipe.Current edition approv
14、ed Feb. 1, 2011. Published March 2011. Originallyapproved in 1980. Last previous edition approved in 2010 as C506M 10b. DOI:10.1520/C0506M-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vol
15、ume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.tests as defined in 11.3.1; by such material tests as are requiredin accordance with 6.2, 6.3, 6.5, and
16、6.6, by an absorption testof the concrete from the wall of the pipe as required in 11.9;and by visual inspection of the finished pipe to determine itsconformance with the accepted design and its freedom fromdefects.5.1.2 Acceptance on the Basis of Material Test and Inspec-tion of Manufactured Pipe f
17、or Defects and ImperfectionsAcceptability of the pipe in all diameters and classes producedin accordance with 7.1 or 7.2 shall be determined by the resultsof such material tests as are required in accordance with 6.2,6.3, 6.5, and 6.6; by crushing tests on concrete cores or curedconcrete cylinders;
18、by an absorption test of the concrete fromthe wall of the pipe for each mix design that is used on anorder; and by inspection of the finished pipe, including amountand placement of reinforcement, to determine its conformancewith the accepted design and its freedom from defects.5.1.3 When agreed upon
19、 by the owner and the manufacturer,any portion or any combination of the tests itemized in 5.1.1 or5.1.2 may form the basis of acceptance.5.2 Age for AcceptancePipe shall be considered ready foracceptance when they conform to the requirements as indicatedby the specified tests.6. Materials6.1 Reinfo
20、rced ConcreteThe reinforced concrete shallconsist of cementitious materials, mineral aggregates, andwater, in which steel has been embedded in such a manner thatthe steel and concrete act together.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirementsof Specification C150, o
21、r shall be portland blast-furnace slagcement, or slag modified portland cement, or portland-pozzolan cement conforming to the requirements of Specifica-tion C595, except that the pozzolan constituent in the Type IPportland pozzolan cement shall be fly ash and shall not exceed25 % by weight.6.2.2 Gro
22、und Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120of Specification C989.TABLE 1 Strength Requirements for Reinforced Concrete PipeAApprox-imateEquivalentRoundSize,mmT,mmMini-mumRise,mmMini-mumSpan,mmf8cBMPaDouble Line ReinforcementCSingle LineReinfor
23、cementContinuous BasicReinforcement = AsDAdditional Reinforcement = AsDClass Inner Cage Outer Cage“U ”(Inner Cage)“V ”(Outer Cage)A-II A-III A-IV A-II A-III A-IV A-II A-III A-IVDimen-sion,mmA-II A-III A-IVDimen-sion,mmA-II A-III A-IV A-II A-III A-IV375 57 280 460 27.6 27.6 27.6 . . . . . . . . . . .
24、 . . . 1.7 2.5 3.6450 63 345 560 27.6 27.6 27.6 . . . . . . . . . . . . . . 2.3 3.0 5.5525 69 395 660 27.6 27.6 27.6 . . . . . . . . . . . . . . 2.8 3.6 6.1600 75 460 725 27.6 27.6 27.6 . . . . . . 660 . . . 735 . . . 3.4 4.6 6.8750 88 570 920 27.6 27.6 27.6 1.9 2.5 3.8 1.5 1.9 3.0 760 1.9 2.5 3.8 8
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC506M2011STANDARDSPECIFICATIONFORREINFORCEDCONCRETEARCHCULVERTSTORMDRAINANDSEWERPIPEMETRIC 钢筋混凝土

链接地址:http://www.mydoc123.com/p-466843.html