ASTM C478M-2007 Standard Specification for Precast Reinforced Concrete Manhole Sections [Metric]《预制钢筋混凝土检修孔构件的标准规范(米制)》.pdf
《ASTM C478M-2007 Standard Specification for Precast Reinforced Concrete Manhole Sections [Metric]《预制钢筋混凝土检修孔构件的标准规范(米制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C478M-2007 Standard Specification for Precast Reinforced Concrete Manhole Sections [Metric]《预制钢筋混凝土检修孔构件的标准规范(米制)》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 478M 07METRICStandard Specification forPrecast Reinforced Concrete Manhole Sections Metric1This standard is issued under the fixed designation C 478M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.PART IGENERAL1. Scope1.1 This specification covers th
3、e manufacture and purchaserequirements of products used for the assembly and construc-tion of circular precast reinforced concrete manholes used insewer and water works.1.2 Part I, Sections 1-11, of this specification presentsgeneral requirements and requirements which are common toeach precast conc
4、rete product covered by this specification.1.3 Part II of this specification presents specific require-ments for each manhole product in the following sections:Product SectionGrade Rings 12Flat Slab Tops 13Risers and Conical Tops 14Base Sections 15Steps and Ladders 16NOTE 1Future products will be in
5、cluded in Part II in a future revisionof this specification.1.4 This is the metric (SI) companion to SpecificationC 478.NOTE 2This specification is a manufacturing and purchase specifica-tion only, and does not include requirements for backfill, or the relation-ship between field load conditions and
6、 the strength requirements of themanhole products and appurtenances. Experience has shown, however,that the successful performance of this product depends upon the properselection of the product strength, type of foundation and backfill, and carein the field installation of the manhole products and
7、connecting pipes. Theowner of the project for which these products are specified herein iscautioned to require inspection at the construction site.2. Referenced Documents2.1 ASTM Standards:2A 82/A 82M Specification for Steel Wire, Plain, for Con-crete ReinforcementA 185/A 185M Specification for Stee
8、l Welded Wire Rein-forcement, Plain, for ConcreteA 496/A 496M Specification for Steel Wire, Deformed, forConcrete ReinforcementA 497/A 497M Specification for Steel Welded Wire Rein-forcement, Deformed, for ConcreteA 615/A 615M Specification for Deformed and PlainCarbon-Steel Bars for Concrete Reinfo
9、rcementA 706/A 706M Specification for Low-Alloy Steel De-formed and Plain Bars for Concrete ReinforcementC33 Specification for Concrete AggregatesC 39/C 39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC 150 Specification for Portland CementC 260 Specification for Air-Entra
10、ining Admixtures for Con-creteC 309 Specification for Liquid Membrane-Forming Com-pounds for Curing ConcreteC 494/C 494M Specification for Chemical Admixtures forConcreteC 497 Test Methods for Concrete Pipe, Manhole Sections,or TileC 595 Specification for Blended Hydraulic CementsC 618 Specification
11、 for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC 822 Terminology Relating to Concrete Pipe and RelatedProductsC 989 Specification for Ground Granulated Blast-FurnaceSlag for Use in Concrete and MortarsC 1017/C 1017M Specification for Chemical Admixtures1This specification i
12、s under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholesand Specials.Current edition approved March 1, 2007. Published March 2007. Originallyapproved in 1980. Last previous edition approved in 2006 as C 478M 06b.2For reference
13、d ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
14、shohocken, PA 19428-2959, United States.for Use in Producing Flowing Concrete2.2 ACI Standard:ACI 318 Building Code, Requirements for Reinforced Con-crete33. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C 822.4. Materials and Manufacture4.1 General m
15、aterial requirements for precast reinforcedconcrete manhole products are presented in 4.1.1-4.1.8. Othermaterials or additional requirements for a product, if any, arecovered in the Part II section for that specific product.4.1.1 Reinforced ConcreteReinforced concrete shall con-sist of cementitious
16、materials, mineral aggregates, and water, inwhich steel reinforcement has been embedded in such amanner so that the steel reinforcement and concrete acttogether.4.1.2 Cementitious Materials:4.1.2.1 CementCement shall conform to the requirementsfor portland cement of Specification C 150, or shall be
17、portlandblast-furnace slag cement or portland-pozzolan cement con-forming to Specification C 595, except that the pozzolanconstituent of the Type IP portland-pozzolan cement shall befly ash.4.1.2.2 Fly AshFly ash shall conform to the requirementsof Class F or Class C of Specification C 618.4.1.2.3 G
18、round Granulated Blast-Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120of Specification C 989.4.1.3 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in the concreteshall be one of the following:4.1.3.1 Portland cement only,
19、4.1.3.2 Portland blast-furnace slag cement only,4.1.3.3 Slag modified Portland cement only,4.1.3.4 Portland pozzolan cement only,4.1.3.5 A combination of Portland cement and groundgranulated blast-furnace slag,4.1.3.6 A combination of Portland cement and fly ash, or4.1.3.7 A combination of Portland
20、cement, ground granu-lated blast-furnace slag (not to exceed 25 % of the totalcementitious weight) and fly ash (not to exceed 25 % of thetotal cementitious weight).4.1.4 AggregatesAggregates shall conform to Specifica-tion C33, except that the requirements for gradation shall notapply.4.1.5 Admixtur
21、es and BlendsThe following admixturesand blends are allowable:4.1.5.1 Air-entraining admixture conforming to Specifica-tion C 260;4.1.5.2 Chemical admixture conforming to SpecificationC 494/C 494M;4.1.5.3 Chemical admixture for use in producing flowingconcrete conforming to Specification C 1017/C 10
22、17M;4.1.5.4 Chemical admixture or blend approved by theowner.4.1.6 Steel ReinforcementReinforcement shall consist ofwire conforming to Specification A 82/A 82M or SpecificationA 496/A 496M, of wire fabric conforming to SpecificationA 185/A 185M or Specification A 497/A 497M, or of bars ofGrade 40 st
23、eel conforming to Specification A 615/A 615M orof bars conforming to Specification A 706/A 706M.4.1.7 Secondary Synthetic FiberCollated fibrillatedpolypropylene virgin fibers shall not be prohibited when usedin steel reinforced concrete manholes as a non-structuralmanufacturing enhancement. Only fib
24、ers designed and manu-factured specifically for use in concrete and so certified by themanufacturer shall be accepted.4.1.8 Other MaterialsOther materials required for a prod-uct and not covered in Section 4 will be covered in the Part IIsection for that specific product.5. Design5.1 Design requirem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC478M2007STANDARDSPECIFICATIONFORPRECASTREINFORCEDCONCRETEMANHOLESECTIONSMETRIC 预制 钢筋混凝土 检修 构件 标准规范

链接地址:http://www.mydoc123.com/p-466709.html