ASTM C412M-2005a Standard Specification for Concrete Drain Tile (Metric)《混凝土排水瓦管标准规范(米制)》.pdf
《ASTM C412M-2005a Standard Specification for Concrete Drain Tile (Metric)《混凝土排水瓦管标准规范(米制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C412M-2005a Standard Specification for Concrete Drain Tile (Metric)《混凝土排水瓦管标准规范(米制)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 412M 05aMETRICStandard Specification forConcrete Drain Tile Metric1This standard is issued under the fixed designation C 412M; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pa
2、rentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers concrete drain tile with inter-nal diam
3、eters from 100 to 900 mm, that are intended to be usedfor surface and subsurface drainage.1.2 This specification is the metric counterpart of Specifi-cation C 412.NOTE 1This specification is a manufacturing and purchase specifica-tion only and does not include requirements for bedding, backfill, or
4、therelationship between field load condition and the strength classification ofdrain tile. However, experience has shown that the successful performanceof the product depends upon the proper selection of the class of drain tile,type of bedding and backfill, and care that the installation conforms to
5、 theconstruction specifications. The owner is cautioned that he must correlatethe field requirements with the class of drain tile specified and provide foror require inspection at the construction site.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC 150 Specific
6、ation for Portland CementC 497M Test Methods for Testing Concrete Pipe, ManholeSections, or Tile MetricC 595 Specification for Blended Hydraulic CementsC 618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC 822 Terminology Relating to Concrete Pipe and RelatedP
7、roductsC 989 Specification for Ground Granulated Blast-FurnaceSlag for Use in Concrete and MortarsC 1116 Specification for Fiber-Reinforced Concrete andShotcrete3. Terminology3.1 DefinitionsFor definitions of terms relating to con-crete pipe, see Terminology C 822.4. Classification4.1 Drain tile man
8、ufactured according to this specificationshall be of the following four classes:4.1.1 Standard-Quality Concrete Drain Tile, intended forland drainage of ordinary soils where the tile are laid intrenches of moderate depths and widths. Standard-Qualityconcrete drain tile are not recommended for use wh
9、ere internaldiameters in excess of 300 mm are required.4.1.2 Extra-Quality Concrete Drain Tile, intended for landdrainage of ordinary soils where the tile are laid in trenches ofconsiderable depths or widths, or both.4.1.3 Heavy-Duty Extra-Quality Concrete Drain Tile, in-tended for land drainage of
10、ordinary soils where the tile are laidin trenches of large depths or widths, or both.4.1.4 Special-Quality Concrete Drain Tile, intended for landdrainage where special precautions are necessary for concretetile laid in soils that are markedly acid or contain unusualquantities of sulfates (see Sectio
11、n 7), and where the tile are laidin trenches of considerable depths or widths, or both.4.1.4.1 Where the calculated loads are in excess of thecrushing strengths prescribed in the physical requirements forextra-quality and special-quality concrete drain tile, tilestrengths must be specified in advanc
12、e by the owner.5. Basis of Acceptance5.1 The acceptability of drain tile shall be determined by (1)the results of the physical tests as specified in Section 8, and inTest Methods C 497M,(2) measurements and inspection toascertain whether the tile conform to the requirements regard-ing dimensions, sh
13、ape, and freedom from visible defects, and(3) the manufacturers certification in writing that the tile have1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.01 onNon-Reinforced Concrete Sewer, Drain, and Irrigatio
14、n Pipe.Current edition approved Dec. 1, 2005. Published January 2006. Originallyapproved in 1980. Last previous edition approved in 2005 as C 412M 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStand
15、ards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.been made in accordance with any special provisions, such asstrength, absorption, permeability,
16、type of cement, admixture,curing conditions, etc.5.2 The owner shall specify in writing the class or classes ofconcrete tile to be supplied, whether Standard-Quality, Extra-Quality, Heavy-Duty Extra-Quality, or Special-Quality. UnlessExtra-Quality, Heavy-Duty Extra-Quality, or Special-Qualityconcret
17、e drain tile have been specified, Standard-Quality draintile shall be accepted.6. Materials6.1 ConcreteThe concrete shall consist of cementitiousmaterials, mineral aggregates, and water, in which steel hasbeen embedded in such a manner that the steel and concrete acttogether.6.2 Cementitious Materia
18、ls:6.2.1 CementCement for shall conform to the require-ments for portland cement of Specification C 150 or shall beportland blast-furnace slag cement, or slag-modified portlandcement, or portland-pozzolan cement conforming to the re-quirements of Specification C 595, except that the pozzolanconstitu
19、ent in the Type IP portland-pozzolan cement shall befly ash.6.2.2 Fly AshFly ash shall conform to the requirements ofSpecification C 618, Class F or Class C.6.2.3 Ground Granulated Blast Furnace Slag (GGBFS)GGBFS shall conform to the requirements of Grade 100 or 120of Specification C 989.6.2.4 Allow
20、able Combinations of Cementitious MaterialsThe combination of cementitious materials used in the concreteshall be one of the following:6.2.4.1 Portland cement only,6.2.4.2 Portland blast furnace slag cement only,6.2.4.3 Slag modified portland cement only,6.2.4.4 Portland pozzolan cement only,6.2.4.5
21、 A combination of portland cement and fly ash,6.2.4.6 A combination of portland cement and groundgranulated blast-furnace slag, or6.2.4.7 A combination of portland cement, fly ash (not toexceed 25 % of the total cementitious weight) and groundgranulated blast furnace slag (not to exceed 25 % of the
22、totalcementitious weight).6.3 AggregatesAggregates shall conform to SpecificationC33, except that the requirements for gradation shall notapply.6.4 Admixtures and BlendsAdmixtures and blends shallonly be used with the approval of the owner.6.5 Synthetic FibersAt the manufacturers option, col-lated f
23、ibrillated virgin polypropylene fibers are not prohibitedfrom being used as a nonstructural manufacturing material.Only Type III synthetic fibers designed and manufacturedspecifically for use in concrete and conforming to the require-ments of Specification C 1116 shall be used.7. Chemical Requiremen
24、ts7.1 Acid and Sulfate Resistance:7.1.1 The owner is not prohibited from specifying specialrequirements in order to increase the durability of the drain tilein cases where the soils, soil waters, or drainage waters aremarkedly acid or contain moderate or severe quantities of soilsulfates. Without a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC412M2005ASTANDARDSPECIFICATIONFORCONCRETEDRAINTILEMETRIC 混凝土 排水 标准规范 米制 PDF

链接地址:http://www.mydoc123.com/p-466515.html