1、Designation: C411 17Standard Test Method forHot-Surface Performance of High-Temperature ThermalInsulation1This standard is issued under the fixed designation C411; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method covers the determinati
3、on of the perfor-mance of commercial sizes of both block and pipe forms ofthermal insulating materials when exposed to simulated hot-surface application conditions. The term “hot-surface perfor-mance” has reference to a simulated use-temperature test inwhich the heated testing surface is in a horizo
4、ntal position.1.2 This test method refers primarily to high-temperatureinsulations that are applicable to hot-side temperatures inexcess of 150F (66C). It is used for materials such aspreformed insulations, insulating cements, blankets, and thelike, by proper laboratory preparation of the samples.1.
5、3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associ
6、ated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally reco
7、gnized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C167 Test Methods fo
8、r Thickness and Density of Blanket orBatt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulation Subjected to SoakingHeat3. Terminology3.1 DefinitionsTerminology C168 shall apply to the termsused in thi
9、s test method.3.2 Definitions of Terms Specific to This Standard:3.2.1 sag, nthe extent of thickness loss of pipe insulation,at the top longitudinal center, due to material fatigue ordecomposition due to elevated temperature.4. Significance and Use4.1 Performance in service is the final measure of v
10、alue fora thermal insulation, but simulative service tests give usefulindications. One type involves application for a specified timeto a surface heated at a temperature approximately that ofintended service, and noting during the test and afterward,changes in the material and its properties. Measur
11、ement ofthese changes are used for predicting what occurs in service asa result of exposure to temperatures corresponding to those ofthe tests.5. Apparatus5.1 Heating PlateThe heating plate shall consist of acorrosion-resistant and heat-resistant plate with a preferredexposed test area of 36 by 18 i
12、n. (914 by 457 mm), but havinga minimum test area of 18 by 18 in. (457 by 457 mm). Theheated area shall have an insulated, heated guard area having aminimum width of 3 in. (76 mm) around the entire periphery ofthe test area. The plate shall be supported in a horizontal planeat a sufficient number of
13、 points to prevent sagging. It shall beheated on the under side by gas or electricity. The surfacetemperature of the plate shall be measured by not less than fivethermocouples. Four of the thermocouples shall be locatedalong the diagonals that extend from the corners of the exposedarea of the plate
14、and at a distance of 6 in. (152 mm) in fromeach corner. A fifth thermocouple shall be located near the1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.31 on Chemical andPhysical Properties.Current edition appro
15、ved Oct. 1, 2017. Published November 2017. Originallyapproved in 1958. Last previous edition approved in 2011 as C411 11. DOI:10.1520/C0411-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vo
16、lume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on sta
17、ndardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1center of the test plate area. The temperature at no point ofmeasurement shall vary mor
18、e than 65%or625F (614C),whichever is less, from the desired temperature. A heatingchamber beneath the heating plate shall be formed to retain theheat generated by the heating means. A 6-in. thickness ofinsulation shall form the bottom and the sides, and the heatingplate shall form the top of the cha
19、mber. Two suitable types ofheating plates are shown in Fig. 1 and Fig. 2.5.2 Heating PipeThe heating pipe shall consist of acorrosion-resistant and heat-resistant pipe having a length ofnot less than 3 ft (0.9 m) and preferably 6 ft 6 in. (1.98 m). Itshall be supported horizontally. The nominal diam
20、eter of thepipe shall preferably be 3 in. (76 mm). The pipe shall be heatedelectrically with a spiral heating coil placed along the inside ofthe pipe. Supplementary end heaters, and a guard section atleast 3 in. long of the same insulation as that being placed onthe test section, shall also be provi
21、ded to guard againstexcessive losses from the ends of the test specimen. (Wherepossible, the use of standard thermal conductivity pipe testapparatus to serve as the heating pipe is recommended.) Thesurface temperature of the pipe shall be measured by means ofthermocouples, not less than one for each
22、 1 ft (0.3 m) of lengthof the test specimen, and located spirally around the pipe at 90intervals. The test portion of the pipe shall be that area undera full length of a pipe insulation undergoing test. The tempera-ture at any point of measurement on the test portion shall notvary more than 65%or625
23、F (614C), whichever is less,from the desired temperature.5.3 Temperature MeasurementThermocouples shall beused to measure the surface temperature of the heating plateand the heating pipe. They shall be applied either by peeningthe individual wires into small holes drilled into the surface andseparat
24、ed by not more than18 in. (3 mm) or by joining thewires with a welded bead and cementing them in grooves withthe bead tangent to the surface but not projecting above it. Thethermocouples shall be made from wires having a size notgreater than No. 22Awg (0.644 mm), and preferably not largerthan No. 26
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC4112017STANDARDTESTMETHODFORHOTSURFACEPERFORMANCEOFHIGHTEMPERATURETHERMALINSULATION 高温 隔热材料 受热 性能

链接地址:http://www.mydoc123.com/p-466511.html