1、Designation: C 1405 07Standard Specification forGlazed Brick (Single Fired, Brick Units)1This standard is issued under the fixed designation C 1405; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers brick, having a ceramic glazefinish fused to the body during the same process as the unitbody firing, that are i
3、ntended for use in masonry and supplyingstructural or facing components, or both, to the structure. Thisspecification does not cover double-fired glazed brick. Somedouble-fired decorative glazes have physical properties whichvary from those of single-fired glazes due to the lowertemperatures used in
4、 applying the decorative coating.1.2 The property requirements of this specification apply atthe time of purchase. The use of results from testing of brickextracted from masonry structures for determining conform-ance or nonconformance to the property requirements of thisspecification is beyond the
5、scope of this specification.1.3 Glazed brick are prismatic units available in a variety ofsizes, textures, colors, and shapes. Glazed brick are manufac-tured from clay, shale, or similar naturally occurring earthysubstances and subjected to a heat treatment at elevatedtemperatures (firing). The heat
6、 treatment shall develop a firedbond between the particulate constituents to provide thestrength and durability requirements of this specification (seefiring, fired bond, glaze, and incipient fusion in TerminologyC43).1.4 Glazed brick are shaped during manufacture by mold-ing, pressing, or extrusion
7、, and the shaping method is a way todescribe the brick.1.5 Glazed brick are classified into one of two grades, one oftwo types, one of two classes, and one of three divisions.1.6 Opacity of the glaze is not required unless specified bythe purchaser.1.7 The text of this standard references notes and
8、footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of this standard.1.8 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1
9、.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Do
10、cuments2.1 ASTM Standards:2C43 Terminology of Structural Clay ProductsC67 Test Methods for Sampling and Testing Brick andStructural Clay TileC 1093 Practice for Accreditation of Testing Agencies forUnit MasonryE84 Test Method for Surface Burning Characteristics ofBuilding Materials2.2 NFPA Standard:
11、NFPA No. 255 Test for Surface Burning Characteristics ofBuilding Materials32.3 UL Standard:UL No. 723 Flammability Studies of Cellular Plastics andOther Building Materials Used for Interior Finishes42.4 ICBO Standard:UBC No. 42-1 Test Method for Fire Hazard Classificationof Building Material52.5 Fed
12、eral Standard:Federal Standard Test No. 141 Abrasion Resistance (TaberAbraser)63. Terminology3.1 DefinitionsTerms used in this specification are definedin accordance with Terminology C43.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direc
13、t responsibility of SubcommitteeC15.02 on Brick and Structural Clay Tile.Current edition approved June 1, 2007. Published June 2007. Originallyapproved in 1998. Last previous edition approved in 2005 as C 1405 05a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM C
14、ustomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.4Available from Underwri
15、ters Laboratories (UL), 333 Pfingsten Rd., North-brook, IL 60062-2096, http:/.5Available from the International Conference of Building Officials, 5360 SouthWorkman Mill Road, Whittier, CA 90601.6Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail S
16、top: SDE, Washington, DC 20401, http:/www.access.gpo.gov.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Classification4.1 GradesGrades classify glazed brick accord
17、ing to theirpermissible variation in face dimension as follows. Whengrade is not specified, the requirements for Grade S govern.4.1.1 Grade S (Standard), units for use where standarddimensional tolerances are desired.4.1.2 Grade SS (Select Sized), units for use where a higherdegree of precision and
18、lower permissible variation in size aredesired.4.2 TypesTwo types of glazed brick are covered. Whentype is not specified, the requirements for Type I govern.4.2.1 Type I (Single-Faced Units), for general use whereonly one face is finished.4.2.2 Type II (Two-Faced Units), for use where two oppositefa
19、ces are finished.4.3 ClassesTwo classes of glazed brick are covered.When class is not specified, the requirements for Class Exteriorgovern.4.3.1 Class Exterior, for exterior applications.4.3.2 Class Interior, for interior applications.NOTE 1Special brick shapes may be desired by the purchaser that d
20、onot meet all of the requirements of this specification (see 8.2.1). Consultthe manufacturer for availability of special units and suitability for theintended purpose.4.4 DivisionsThree divisions of glazed brick are covered.Divisions identify the amount and placement of hollow spaces(cores, cells an
21、d deep frogs) in the cross section of the unit. Inthe Division nomenclature, H shall be understood to meanhollow, and V shall be understood to mean void.4.4.1 Division SolidBrick with void area less than orequal to 25 % of its gross cross sectional area, measured in anyplane parallel to the surface
22、containing the cores, cells, or deepfrogs.4.4.2 Division H40VBrick with void area greater than25 % but less than or equal to 40 % of its gross cross sectionalarea, measured in any plane parallel to the surface containingthe cores, cells, or deep frogs.4.4.3 Division H60VBrick with void area greater
23、than40 % but less than or equal to 60 % of its gross cross sectionalarea, measured in any plane parallel to the surface containingthe cores, cells, or deep frogs. The shell thicknesses shallcomply with the requirements in Table 1. See Fig. 1.5. Physical Properties5.1 DurabilityGlazed brick shall con
24、form to the physicalproperties requirements for the class specified as prescribed inTable 2 or in 5.1.1 or 5.1.2. For the compressive strengthrequirements, test the unit with the compressive force perpen-dicular to the bed surface of the unit, with the unit in thestretcher position.NOTE 2The physica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC14052007STANDARDSPECIFICATIONFORGLAZEDBRICKSINGLEFIREDBRICKUNITS 釉面砖 标准规范 一次 烧成 砖块 PDF

链接地址:http://www.mydoc123.com/p-464523.html