ASTM B415-1998(2013) Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire《硬拉包铝钢丝标准规格》.pdf
《ASTM B415-1998(2013) Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire《硬拉包铝钢丝标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B415-1998(2013) Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire《硬拉包铝钢丝标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B415 98 (Reapproved 2013)Standard Specification forHard-Drawn Aluminum-Clad Steel Wire1This standard is issued under the fixed designation B415; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers four conductivities of b
3、are,hard-drawn, round, aluminum-clad steel wire for general usefor electrical purposes in sizes 0.2043 to 0.0808 in. incl (4 to 12AWG) (Note 1). This specification does not apply to wires usedas reinforcement in ACSR conductors. (See SpecificationB502.)NOTE 1Wire ordered to this specification is not
4、 intended for redraw-ing. If wire is desired for this purpose, the manufacturer shall beconsulted.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not conside
5、red standard.2. Referenced Documents2.1 The following documents of the issue in effect on thedate of material purchase form a part of this Specification to theextent referenced herein.2.2 ASTM Standards:2B193 Test Method for Resistivity of Electrical ConductorMaterialsB502 Specification for Aluminum
6、-Clad Steel Core Wire forUse in Overhead Electrical Aluminum Conductors3. Ordering Information3.1 Orders for material under this specification shall includethe following information:3.1.1 Quantity and conductivity of each size,3.1.2 Wire size: diameter in inches (see 7.1 and Table 1),3.1.3 Method of
7、 measuring elongation if other than 5.3(optional),3.1.4 Special package marking if required (Section 16), and3.1.5 Package size (see 17.1), and3.1.6 Place of inspection if other than place of manufacture(Section 14).4. Material4.1 The wire shall be composed of a steel core with asubstantially unifor
8、m and continuous aluminum covering thor-oughly bonded to it. The drawn wire shall have the propertiesand characteristics prescribed in this specification.5. Tensile Properties5.1 The wire shall conform to the tensile requirementsprescribed in Table 1 (Note 2). In computing tensile strength,the actua
9、l diameter of the finished wire shall be used.NOTE 2The approximate properties of standard AWG sizes ofhard-drawn aluminum-clad steel wire are shown in Table 2 for theinformation of the user of this specification.5.2 Wire of a nominal diameter that exceeds a size listed inTable 1 shall conform to th
10、e tensile requirements of the nextlarger diameter.5.3 Elongation shall be determined by an extensometersuitable for measuring elongation in 10 in. (250 mm) andequipped with a vernier reading to 0.01 in. (0.25 mm). It shallbe attached to the test specimen at a tensile load of 10 % of therated strengt
11、h. The elongation shall be observed while applyinga tension load to the specimen. The reading at the time offracture shall be taken as the elongation of the specimen. Theelongation thus determined shall be not less than 1.5 % in 10in. Tests shall be disregarded in which the extensometerreading is le
12、ss than 1.5 % and in which the fracture does notoccur between the extensometer attachments and at least 1 in.(25.0 mm) from the two attachments. In this case anothersample from the same reel or coil shall be tested.5.4 When agreed upon by the manufacturer and thepurchaser, the elongation may be dete
13、rmined by measurementsmade between the jaws of the testing machine. The zero lengthshall be the distance between the jaws when a load equal to10 % of the specified tensile strength shall have been appliedand the final length shall be the distance between the jaws atthe time of rupture. The zero leng
14、th shall be as near 60 in. (1.52m) as practicable. The elongation thus determined shall be not1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.06 onComposite Conductors.Current edition approved April 1, 2
15、013. Published April 2013. Originallyapproved in 1964. Last previous edition approved in 2007 as B415 98 (2007).DOI: 10.1520/B0415-98R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume i
16、nformation, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1less than 1.4 %. Tests in which the elongation is less than 1.4 %and in which the fracture occurs at or within
17、 1 in. (25.4 mm)of the jaws shall be disregarded. In this case another samplefrom the same reel or coil shall be tested.6. Resistance6.1 The electrical resistance of the wire (Note 2 and Note 3)shall be determined by resistance measurements and maximumresistance shall be based on the nominal diamete
18、r of the wireand the resistivity value of:51.01 cmil/ft at 20C for 20.3 % Conductivity38.41cmil/ft at 20C for 27 % Conductivity34.57 cmil/ft at 20C for 30 % Conductivity25.93 cmil/ft at 20C for 40 % ConductivityNOTE 3Electrical resistance is calculated by the following equation:Resistance, /ft 5 Res
19、istivity cmil/ft!/nominal diameter, mils!26.2 When resistance measurements are made at tempera-tures other than 20C, corrections shall be based on thecorresponding temperature coefficient of resistance shown inTable 2.6.3 The electrical resistivity of the material shall be deter-mined in accordance
20、with Test Method B193.7. Dimensions and Permissible Variations7.1 The size shall be expressed by the wire diameter indecimal fractions of an inch to the nearest 0.0001 in. (0.0025mm), that is, in tenths of mils.7.2 Within the range of diameters included in Table 3, thewire shall not vary from the sp
21、ecified diameter by more thanthe amounts shown in this table. In computing permissiblevariations, diameters shall be rounded to the nearest 0.0001 in.(0.0025 mm).7.3 If accessible, one diameter measurement shall be takennear each end and one near the middle of the coil or reel. In thecase of reels,
22、the center and one end may not be accessible andthe prescribed diameter measurement shall be taken along thelength of the accessible material. If any of the selected coils orreels fail to conform to the requirements for diameter asprescribed in 7.2, all coils or reels shall be measured in themanner
23、specified.8. Thickness of Aluminum8.1 The aluminum thickness at any point shall be not lessthan stated in Table 4. Measurements shall be read to theclosest 0.001 in. (0.025 mm). In determining the required ormeasured thickness, 0.0005 in. (0.013 mm) or less shall bedropped. For greater than 0.0005 i
24、n., the next larger 0.001 in.shall be used. Measurements shall be made by (a) usingsuitable electrical indicating instruments operating on thepermeameter principle, or (b) direct measurement. For refereepurposes, direct measurement shall be used to determinealuminum thickness on specimens taken from
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB41519982013STANDARDSPECIFICATIONFORHARDDRAWNALUMINUMCLADSTEELWIRE 硬拉包铝 钢丝 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-461170.html