ASTM B233-1997(2007) Standard Specification for Aluminum 1350 Drawing Stock for Electrical Purposes《电气用拉制铝1350条标准规范》.pdf
《ASTM B233-1997(2007) Standard Specification for Aluminum 1350 Drawing Stock for Electrical Purposes《电气用拉制铝1350条标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM B233-1997(2007) Standard Specification for Aluminum 1350 Drawing Stock for Electrical Purposes《电气用拉制铝1350条标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 233 97 (Reapproved 2007)Standard Specification forAluminum 1350 Drawing Stock for Electrical Purposes1This standard is issued under the fixed designation B 233; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers aluminum 1350 drawing stock0.375 in. (9.52 mm) to 1.000 in. (25.40 mm) in diameter, in
3、 thetempers shown in Table 1, for drawing into wire for electricalconductors (Explanatory Note 1 and Note 2).1.2 The SI values of density and resistivity are to beregarded as the standard. For all other properties the inch-pound values are to be regarded as standard and the SI unitsmay be approximat
4、e.NOTE 1Prior to 1975, aluminum 1350 was designated as EC alumi-num.NOTE 2The aluminum and temper designations conform to AN-SI H35.1. Aluminum 1350 corresponds to unified numbering systemA91350 in accordance with Practice E 527.2. Referenced Documents2.1 The following documents of the issue in effe
5、ct on dateof material purchase form a part of this specification to theextent referenced herein:2.2 ASTM Standards:2B 193 Test Method for Resistivity of Electrical ConductorMaterialsB 354 Terminology Relating to Uninsulated Metallic Elec-trical ConductorsB 557 Test Methods for Tension Testing Wrough
6、t and CastAluminum- and Magnesium-Alloy ProductsB 830 Specification for Uniform Test Methods and Fre-quencyE34 Test Methods for ChemicalAnalysis ofAluminum andAluminum-Base AlloysE55 Practice for Sampling Wrought Nonferrous Metals andAlloys for Determination of Chemical CompositionE 227 Test Method
7、for Optical Emission SpectrometricAnalysis of Aluminum and Aluminum Alloys by thePoint-to-Plane Technique3E 527 Practice for Numbering Metals and Alloys in theUnified Numbering System (UNS)2.3 American National Standard:4ANSI H35.1 Alloy and Temper Designation Systems forAluminum1This specification
8、is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.07 onConductors of Light Metals.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1948. Last previous edition approved in 2003 as B 233 97 (
9、2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from American National Standard I
10、nstitute, 11 W. 42nd St., 13thFloor, New York, NY 10036.TABLE 1 Tensile Property LimitsATemperTensile Strengthksi MPa1350-O 8.514.0 59971350-H12 and -H22 12.017.0 831171350-H14 and -H24 15.020.0A1031381350-H16 and -H26 17.022.0A117152AApplicable to stock sizes through 0.500-in. (12.70-mm) diameter.
11、The values toapply for larger sizes in these tempers shall be negotiated at time of inquiry.TABLE 2 Chemical RequirementsAElement Composition, %Silicon, max 0.10Iron, max 0.40Copper, max 0.05Manganese, max 0.01Chromium, max 0.01Zinc, max 0.05Boron, max 0.05Gallium, max 0.03Vanadium plus titanium, to
12、tal, max 0.02Other elements, each, max 0.03Other elements, total, max 0.10Aluminum, min 99.50AAnalysis shall regularly be made only for the elements specified in this table.If, however, the presence of other elements is suspected or indicated in amountsgreater than the specified limits, further anal
13、ysis shall be made to determine thatthese elements are not present in amounts in excess of the specified limits.TABLE 3 Electrical Resistivity LimitsTemperResistivity, Vmm2/m, maxEquivalent VolumeConductivity,% IACS, min1350-O 0.027899 61.81350-H12 and -H22 0.028035 61.51350-H14 and -H24 0.028080 61
14、.41350-H16 and -H26 0.028126 61.31Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.4 National Bureau of Standards:5Handbook 100 Copper Wire Tables3. Ordering Information3.1 Orders for material under this specification shall includeth
15、e following information:3.1.1 Quantity,3.1.2 Diameter (see 11.1),3.1.3 Temper (see Table 1 and Explanatory Note 1 and Note2),3.1.4 Whether joints are permitted (see 8.1),3.1.5 Whether tests of joints are required and number ofspecimens (see 8.2),3.1.6 Coil size and weight (see 14.2),3.1.7 Whether wr
16、apping of coils is required (see 14.3),3.1.8 Special marking on tags, if required (see 14.4), and3.1.9 Whether inspection or witness of inspection and testsby purchasers representative is required prior to shipment (seeSection 13).4. Manufacture4.1 Unless otherwise agreed upon at the time of placing
17、 theorder, the manufacturer shall have the option of producing thestock from either individually cast ingots or continuously castbars. Only one method of production shall be used on anygiven order.4.2 Unless otherwise specified, the manufacturer shall havethe option of supplying stock in the H2X tem
18、per when H1X isspecified, and of supplying stock in the H1X temper when H2Xis specified. Only one temper shall be supplied in any givenorder (see Explanatory Note 3 and ANSI H35.1).5. Chemical Composition5.1 The stock shall conform to the requirements of Table 2as to chemical composition. Conformanc
19、e shall be determinedby the manufacturer by analyzing samples taken at the time theingots or continuously cast bars are poured, or samples takenfrom the finished or semifinished product. If the manufacturerhas determined the chemical composition of the materialduring the course of manufacture, he sh
20、all not be required tosample and analyze the finished product.5.2 Number of SamplesThe number of samples taken fordetermination of chemical composition shall be as follows:5.2.1 When samples are taken at the time the ingots arepoured, at least one sample shall be taken to represent eachgroup of ingo
21、ts poured simultaneously from the same source ofmolten metal.5.2.2 When samples are taken at the time continuously castbars are poured, at least one sample shall be taken to representthe continuously cast length poured from each furnace load ofmolten metal.5.2.3 When samples are taken from the finis
22、hed or semifin-ished product, a sample shall be taken to represent each 5000lb (2300 kg) or fraction thereof of material in the shipment,except that no more than one sample shall be required percontinuous unjointed coil.5.3 Methods of SamplingSamples for determination ofchemical composition shall be
23、 taken in accordance with one ofthe following methods:5.3.1 Samples for chemical analysis shall be taken from thematerial by drilling, sawing, milling, turning, or clipping arepresentative piece or pieces to obtain a weight of preparedsample not less than 75 g. Sampling shall be in accordancewith Pr
24、actice E55.5.3.2 Samples for spectrochemical and other methods ofanalysis shall be suitable for the form of material beinganalyzed and the type of analytical method used.5.4 Methods of AnalysisThe determination of chemicalcomposition shall be made in accordance with suitable chemi-cal (Test Methods
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB23319972007STANDARDSPECIFICATIONFORALUMINUM1350DRAWINGSTOCKFORELECTRICALPURPOSES 电气 拉制 1350 标准规范

链接地址:http://www.mydoc123.com/p-460697.html