1、ASHRAE HANDBOOK Additions and Corrections - This report includes additional information and technical errors found between June 15,2000, and April 1,2003, in the SI edition of the 2000, 2001, and 2002 ASHRAE Handbooks. Occasional typo- graphical errors and nonstandard symbol labels will be corrected
2、 in future volumes. The most current list of Handbook additions and corrections is on the ASHRAE web site (www.ashrae.org). The authors and editor encourage you to notify them if you find other technical errors. Please send corrections to: Handbook Editor, ASHRAE, 1791 Tullie Circle NE, Atlanta, GA
3、30329, or e-mail mowenashrae.org. 2000 HVAC Systems and Equipment p. 1.3, 2nd column. In the Space requirements paragraph the first sentence should read: “A decentralized system may or may not have an equipment room.” p. 7.3,2nd column, 3rd full paragraph, 5th line down. Number should be: 4090 kJkWH
4、 (3.133 kJ/kJ) (1.136) two lines lower: 11 640 kJ/kWh (3.233) 2490 kJkWH (0.692) p. 7.11, 2nd column, 4th paragraph. Change last sentence to read: “The exhaust of a gas turbine has about 1.5 to 3 kW of available heat per kilowatt of power output.” p. 7.11, 2nd column, 5th paragraph. Change “40 MJ” t
5、o read “12 kW.” p. 7.20, 2nd column, 3rd full paragraph. Change “1.4 to 4 MJ per kilowatt” to read “0.3 to 0.9 kW steam per kilowatt.” p. 7.20, 2nd column, 4th paragraph. Change “5.5 to 15 MJ/kW per kilowatt” to read “1 to 3 kW steam per kilowatt.” p. 7.20,2nd column, 5th paragraph. Change “1 1 to 5
6、5 MJkW to read “2.3 to 11.4 kW.” p. 7.28,lst column, 3rd paragraph. Change “600V” to “600 V.” p. 7.28, 1st column, 3rd paragraph. Change “5 Hz” to read “5 cycles.” p. 7.33, 1st column, last paragraph. Change “32 kgh” to read “3200 kg,” and change “3.2 kglh” to read “3.2 kg.” p. 7.33, 1st column, las
7、t paragraph. Change “Thus, the total energy requirement .” to read “Thus, the total power requirement .” p. 7.33,2nd column, 1st full paragraph. Change “energy” to read “power.” p. 7.33, 2nd column, last sentence in Example 1. Change “energy” to read “power.” p. 7.44, 2nd column, last full paragraph
8、. Change “0.012” to “0.04” and “0.024 to “0.07.” Change $/MY to “$/lo3 MJ.” p. 9.4, 2nd column, 1st full paragraph. Delete “by more than 25% of the sensible load.” p. 11.27, Fig. 22. Replace Fig. 22 with the following figure, in which the primary and secondary systems are not shown to be connected.
9、AIR REMOVAL AND DISTRICT EXPANSION SYSTEM - SYSTEM SUPPLY - I COILS I - I 1 - I DOMESTIC TO DHW LOADS FROM COLD WTER SUPPLY I DISTRICT SYSTEM RETURN Fig. 22 Basic Heating System Schematic p. 11.30, 2nd column, 1st bulleted paragraph. Change “thermal capacity” to read “thermal power.” p. 12.2,2nd col
10、umn, Eq. (7). Add to definitions: 1000 = constant to change kJ in c, to J p. 18.7,2nd column, Fig. 13. Should read: “Curve shows performance of a fixed fan size running at a fixed speed.” p. 20.2,lst column, last paragraph. Delete second sentence. p. 25.22, 2nd column, Eq. (11). Change “g.mol/s” to
11、read “mol/s.” p. 25.22, 2nd column, Eq. (13). Change “m3/g.mol” to read p. 25.23, 2nd column, Figures 33 and 34. Change “g.mol” to read “mol” in the equation between 85-90% on the lower right . p. 25.24, 1st column, Table 10. Change g.mol” to read “mol” in the third column heading. “m3/m1.” A.1 A.2
12、2003 ASHRAE Applications Handbook (SI) p.25.26,2nd column, 1st full paragraph. Change “140 J/g.mol” to read “140 J/mol.” p. 26.9, Fuel Oil Preparation System section, 3rd paragraph. Change “156 m2/s” to “156 mm2/s.” p. 32.3, 2nd column. In the definition for n, replace the last two definitions with
13、“1.0 for ceiling heating and floor cooling panels, and 1.1 for floor heating and ceiling cooling panels.” p. 37.1,Ist column, last paragraph, 2nd to last sentence. Delete “the volume of the.” p. 41.11, Ist column. In the section on L Bends, change references from Equation (4) to Equation (5). Change
14、 references from Equa- tion (5) to Equation (6). Change the reference from Equation (6) to Equation (7). p. 42.14, 2nd column, last reference. The year should be 1998 and the edition should be 3rd. p. 44.4, Eqs. (3) and (4). The equations should read as follows: x2 = x1 +E - (X3-X,) cw;y x4 = X3-E ?
15、;y - (X3-X1) (3) (4) 2001 Fundamentals p. 1.8, Example 2, Solution (i), 5th line. Change “Chapter 20” to read “Chapter 19 of the 1997 ASHRAE Handbook-Fundamentals.” p. 1.11, Example 4, Solution, 2nd line. Change “Chapter 20” to read “Chapter 19 of the 1997 ASHRAE Handbook-Fundamentals. p. 1.14, Fig.
16、 16. Change “Heat Amplifier” to read “Temperature Amplifier.” p. 2.1,2nd column, last equation. The kinematic viscosity of dry air (v,) should be 16x m /s 2 p. 2.10, Table 2. The units for E should be pm, not feet. Table 2 Effective Roughness of Conduit Surfaces Mat er i a I E, Pm Commercially smoot
17、h brass, lead, copper, or plastic pipe 1.52 Steel and wrought iron Galvanized iron or steel Cast iron 46 152 259 p. 3.24, Symbols. Delete “mechanical equivalent of heat; or” from the definition for J. p. 8.21, 2nd column, Wind Chill Index section. Replace Equa- tion (80) with the following equation,
18、 and delete the text “and WCI units are kcal/(h.m2). Multiply WCI by 1.162 to convert to SI units of W/m2.” (10.45 + lo. for pi, the entire definition should read only “den- sity incoming air, kg/m3.” p. 16.10, 2nd column. The next to the last sentence under Fresh Pork Holding should read, “Care mus
19、t be taken to maintain the ratio of kilograms of CO, to kilograms of meat for the retention period.” p. 22.7, Airflow Requirements. The units for c should be J/(kg.K), and the symbol for mass flow rate of air should $e rii . p. 25.2, 16th line. Change “metre” to “cubic metre.” p. 30.2, Controls. Cha
20、nge “several hundred feet” to “hundreds of metres.” p. 31.3,2nd column, 4th line. The text in parentheses should read “e., a total area of 3.0 m2 and a capacity of 0.33 m3).” p. 34.3, Example 2 values. Change the unit for Ceiling radiating area from “mm2” to “m2. p. 38.21, Figure 30. Along the x axi
21、s, change “IOo” to lo2.” p. 1.30, Index. Add the following index entry after Load coeff- cients: Louvers, F30.45 sizing, F34.17- 18 A.4 2003 ASHRAE Applications Handbook (SI) h E E o o II w U 1 W 5 a L U s U COMPOSITE INDEX ASHM HANDBOOK SERIES This index covers the current Handbook series published
22、 by ASHRAE. The four volumes in the series are identified as follows: S = 2000 HVAC Systems and Equipment F = 2001 Fundamentals R = 2002 Refrigeration A = 2003 HVAC Applications Alphabetization of the index is letter by Ietter; for example, Heat- ers precedes Heat exchangers, and Floors precedes Flo
23、or slabs. The page reference for an index entry includes the book letter and the chapter number, which may be followed by a decimal point and the beginning page in the chapter. For example, the page num- ber S3 1.4 means the information may be found in the 2000 HVAC Systems and Equipment volume, Cha
24、pter 3 1, beginning on page 4. Each Handbook is revised and updated on a four-year cycle. Because technology and the interests of ASHRAE members change, some topics are not included in the current Handbook series but may be found in the earlier Handbook editions cited in the index. Abbreviations, F3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASHRAEINDEXSI2003COMPOSITEINDEXINCLUDESADDITIONSANDCORRECTIONS 综合指数 包括 补充 修改 PDF

链接地址:http://www.mydoc123.com/p-455233.html