ASD-STAN PREN 2591-C12-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C12 - Air Leakage (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C12部分 漏气 第P1版》.pdf
《ASD-STAN PREN 2591-C12-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C12 - Air Leakage (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C12部分 漏气 第P1版》.pdf》由会员分享,可在线阅读,更多相关《ASD-STAN PREN 2591-C12-1992 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part C12 - Air Leakage (Issue P 1)《航空航天系列 电气和光学连接部件 试验方法 第C12部分 漏气 第P1版》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、E Edition approved for publication 1992-06-05 CEN PREN*2591 (PART*C12) 92 3404584 0026892 T Comments should be sent within six months after the date of publication decision A.E.C.M.A. Technopolis - 175, rue Jean-Jacques Rousseau 921 38 Issy-les-Moulineaux Cdex - FRANCE A. E. C. M .A. STAN DAR D prEN
2、 2591 NORME A.E.C.M.A. A.E.C.M.A. NORM Part CI 2 issue P 1 June 1992 DIT PAR LASSOCIATION EUROPEENNE DES CONSTRUCTEURS DE MATRIEL AROSPATIAL Technopolis - 175, rue Jean-Jacques Rousseau - F-92138 Issy-les-Moulineaux Cdex -Tl. (1 ) 47.36.98.76 UDC : Key words : ENGLISH VERSION Aerospace series Elemen
3、ts of electrical and optical connection Test methods Part CI 2 - Air leakage Srie arospatiale Luft- und Raumfahrt Mthodes dessais Prfverfahren Organes de connexion lectrique et optique Partie CI 2 - tanchit lair Elektrische und optische Verbindungselemente Teil CI 2 - Luftdichtheit This Aerospace Se
4、ries pre-standard has been drawn up under the responsibility of AECMA (Association Europenne des Constructeurs de Matriel Arospatial). It is published on green paper for the needs of AECMA-Members. It has been technically approved by the experts of the concerned Commission following comment by the M
5、ember countries. Subsequent to the publication of this pre-standard, the technical content shall not be changed to an extent that interchangeability is affected, physically ar functionally, without re-identification of the standard. After examination and signature of the AECMA Standard Checking Cent
6、re (NPS) and formal agreement of the Official Services of the Member countries it will be submitted as a draft European Standard to CEN (European Committee for Standardization) for final vote, Nota - Extra copies can be supplied by B.N.A.E. - Technopolis 54 - 199. rile Jean-Jacques Rousseau - 92138
7、ISSY-LES-MOULINEAUX CEDEX C2 Chairman M. J. LE CUNFF I I aecma 1992 - CEN PREN*259L (PART*CL2) 92 3404589 002b893 1 M prEN 2591-C12 Page 3 1 Scope and field of application This standard specifies a method of checking the effectiveness of the seals for ensuring sealing at the interfaces : - mounting
8、panel shell, - shell insulation, - insulation contacts, - insulation wires, of elements of connection subjected to a differential air pressure. It shall be used together with EN 2591. 2 Reference EN 2591 Aerospace series - Elements of electrical and optical connection - Test methods - General c. . 3
9、 Preparation of the specimen 3.1 The specimens shall be wired and fitted with their accessories in accordance with the technical specification. The fixed connector shall be mounted in accordance with the technical specification on a test fixture which enables a pressure to be applied in either direc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN2591C121992AEROSPACESERIESELEMENTSOFELECTRICALANDOPTICALCONNECTIONTESTMETHODSPARTC12AIRLEAKAGEISSUEP1

链接地址:http://www.mydoc123.com/p-451238.html