ASD-STAN PREN 2591-222-2005 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part 222 Insertion Loss (I L ) (Edition P 1)《航空航天系列 电气和光学连接部件的试验方法 第222部分 插入.pdf
《ASD-STAN PREN 2591-222-2005 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part 222 Insertion Loss (I L ) (Edition P 1)《航空航天系列 电气和光学连接部件的试验方法 第222部分 插入.pdf》由会员分享,可在线阅读,更多相关《ASD-STAN PREN 2591-222-2005 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part 222 Insertion Loss (I L ) (Edition P 1)《航空航天系列 电气和光学连接部件的试验方法 第222部分 插入.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM prEN 2591-222 Edition P 1 February 2005PUBLISHED BY THE EUROPEAN ASSOCIATION OF AEROSPACE INDUSTRIES - STANDARDIZATION Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8110 - Fax. + 32 2 775 8111 - www.aecma-stan.orgICS: Descriptors: ENGLISH VERSION Aerospace s
2、eries Elements of electrical and optical connection Test methods Part 222: Insertion Loss (I.L.) Srie arospatiale Organes de connexion lectrique et optique Mthodes dessais Partie 222 : Pertes dinsertion Luft- und Raumfahrt Elektrische und optische Verbindungselemente Prfverfahren Teil 222: Einfgungs
3、dmpfung This “Aerospace Series“ Prestandard has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerne
4、d Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal
5、agreement of AECMA-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of
6、 a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 28 February 2005 Comments should be sent within six months after the date of publication to AECMA-STAN Electrical Domain Copyright 2005 by AECMA-STAN Page 2 prEN 2591-222:2005Fore
7、word This standard was reviewed by the Domain Technical Coordinator of AECMA-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA-STANs General Process Manual, this standard has received approval for Publication. Contents Page 1 S
8、cope 3 2 Normative references. 3 3 Preparation of specimens. 3 4 Apparatus 4 5 Procedure 4 6 Requirement . 5 7 Detail to be specified 5 Annex A (normative) Definition of S parameters 7 Page 3 prEN 2591-222:20051 Scope This standard specifies a measurement method of insertion loss, in the required fr
9、equency bandwith of coax contacts or connectors with characteristic impedance. It shall be used together with EN 2591-100. The measurement is carried out according to vectorial method using “S” parameters (see definition in Annex A). 2 Normative references The following referenced documents are indi
10、spensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591-100, Aerospace series Elements of electrical and optical connection Test methods Par
11、t 100: General 1)3 Preparation of specimens The sampling shall include, for each specified cable, a minimum of two section of coaxial cable with connector in both ends. The first section called “Reference” is constituted as follow (see Figure 1): 60 cm 2,5 mm of coaxial cable 1 male coaxial connecto
12、r (SMA, N or TNC type ) 1 female coaxial connector (SMA, N or TNC type ) Key 1 Coaxial (Std) female connector 2 Coaxial (Std) male connector 3 Coaxial cable; Lg. = 60 cm 2,5 mm Figure 1 1) Published as AECMA Prestandard at the date of publication of this standard 1 23Page 4 prEN 2591-222:2005The coa
13、xial connectors shall be selected to offer optimum performances for each used cable and measured frequency range. They must have a reflection coefficient better than 0,1 ( 20 dB) in the test frequency rouge. It is necessary to use the same type of connector on each section of cable. The second secti
14、on called “Measure” (see Figure 2) is constituted by the same elements as “Reference Section”, the sample to be measured shall be installed in the middle of the section of the cable. Key 1 Coaxial (Std) female connector 2 Device under test 3 Coaxial (Std) male connector 4 Coaxial cable; Lg. = 2 30 c
15、m 2,5 mm Figure 2 4 Apparatus The apparatus shall comprise: Measure equipment include (see Figure 3): vector network analyser calibration kit standard precision adapters a 75 kit of transformation, to perform measurement from 50 network analyser, when it is necessary. 5 Procedure 5.1 Calibration Sel
16、ect measure frequency range and sampling points number. Carry out the complete calibration of network analyse, Part 1 and Part 2 (“S” Parameters, S11, S12, S21and S22) Using calibration kit according to instructions specified by network analyser manufacturer. 3 41 4 2Page 5 prEN 2591-222:20055.2 Mea
17、surement Connect reference section on network analyser, using if necessary, standard precision adapter. Perform the measurement, and run the curves tracer or record the values (S12, S21parameters). Move “reference section”, connect the “measure section” on the equipment, run the measurement and curv
18、e tracer, or record the values as above. 6 Requirement Sample insertion loss, which is measured, is the result of: (section insertion loss reference insertion loss). Insertion loss shall not exceed the values specified in the product standard. (The insertion loss of one contact or connector shall be
19、 the insertion loss of the contact or connector pair divided by two). 7 Detail to be specified The following items shall be specified: coaxial cables part number standard coaxial connectors part number network analyser, manufacturer, type and serial number frequency range sampling point number stand
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN25912222005AEROSPACESERIESELEMENTSOFELECTRICALANDOPTICALCONNECTIONTESTMETHODSPART222INSERTIONLOSSILEDITIONP1

链接地址:http://www.mydoc123.com/p-451183.html