ASD-STAN PREN 2591-221-2005 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part 221 Votage Standing Wave Ratio (VSWR) (Edition P 1)《航空航天系列 电气和光学连接部件的试验.pdf
《ASD-STAN PREN 2591-221-2005 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part 221 Votage Standing Wave Ratio (VSWR) (Edition P 1)《航空航天系列 电气和光学连接部件的试验.pdf》由会员分享,可在线阅读,更多相关《ASD-STAN PREN 2591-221-2005 Aerospace Series Elements of Electrical and Optical Connection Test Methods Part 221 Votage Standing Wave Ratio (VSWR) (Edition P 1)《航空航天系列 电气和光学连接部件的试验.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM prEN 2591-221 Edition P 1 February 2005PUBLISHED BY THE EUROPEAN ASSOCIATION OF AEROSPACE INDUSTRIES - STANDARDIZATION Gulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8110 - Fax. + 32 2 775 8111 - www.aecma-stan.orgICS: Descriptors: ENGLISH VERSION Aerospace s
2、eries Elements of electrical and optical connection Test methods Part 221: Voltage Standing Wave Ratio (VSWR) Srie arospatiale Organes de connexion lectrique et optique Mthodes dessais Partie 221 : Ratio dOndes Stationnaires Luft- und Raumfahrt Elektrische und optische Verbindungselemente Prfverfahr
3、en Teil 221: StehwellenverhltnisThis “Aerospace Series“ Prestandard has been drawn up under the responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the
4、 experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and rev
5、iew by users and formal agreement of AECMA-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giv
6、ing the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 28 February 2005Comments should be sent within six months after the date of publication to AECMA-STAN Electrical Domain Copyright 2005 by AECMA-STAN Page 2
7、 prEN 2591-221:2005Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA-STANs General Process Manual, this standard has received approval for Publica
8、tion. Contents Page 1 Scope 3 2 Normative references. 3 3 Preparation of specimens. 3 4 Apparatus 4 5 Procedure 5 6 Requirement . 5 7 Detail to be specified 5 Annex A (normative) Definition of S parameters 7 Page 3 prEN 2591-221:20051 Scope This standard specifies a measurement method of VSWR, in th
9、e required frequency bandwith of coax contacts or connectors with characteristic impedance. It shall be used together with EN 2591-100. The measurement is carried out according to vectorial method using “S” parameters (see definition in Annex A). 2 Normative references The following referenced docum
10、ents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591-100, Aerospace series Elements of electrical and optical connection Tes
11、t methods Part 100: General 1)3 Preparation of specimens Method “A” This method is applicable when exist accurate adapter in the series of connectors or contacts to tested. The sampling shall include, for each specified cable, one section of coaxial cable with device under test in both ends. The sec
12、tion is constituted as follow (see Figure 1): 60 cm 2,5 mm of coaxial cable 1 male coaxial device 1 female coaxial device Key 1 Male coaxial device 2 Female coaxial device 3 Coaxial cable; Lg. = 60 cm 2,5 mm Figure 1 1) Published as AECMA Prestandard at the date of publication of this standard 1 2 3
13、Page 4 prEN 2591-221:2005Method “B” This method is applicable when exist accurate adapter in the series of connectors or contacts to tested. The sampling shall include for each specified cable, one section of coaxial cable with standard connectors in both end, and device under test in the middle of
14、the section of the cable. The section is constituted as follow (see Figure 2): 60 cm 2,5 mm of coaxial cable divided in 2 (2 30 cm) 1 male coaxial standard connector (SMA, Nor TNC type ) 1 female coaxial standard connector (SMA, Nor TNC type ) 1 male coaxial device 1 female coaxial device Key 1 Coax
15、ial (Std) male connector 2 Device under test 3 Coaxial (Std) female connector 4 Coaxial cable; Lg. = 2 30 cm 2,5 mm Figure 2 4 Apparatus The apparatus shall comprise: Measure equipment include (see Figure 3): vector network analyser calibration kit standard precision adapters a 75 kit of transformat
16、ion, to perform measurement from 50 network analyser, when it is necessary. 3 41 4 2Page 5 prEN 2591-221:20055 Procedure 5.1 Calibration Select measure frequency range and sampling points number. Carry out the complete calibration of network analyse, Part 1 and Part 2 (“S” Parameters, S11, S12, S21a
17、nd S22) Using calibration kit according to instructions specified by network analyser manufacturer. 5.2 Measurement Method A Connect the section in measure on network analyser, using if necessary, standards accurate adapters, and perform the measurement. The VSWR of one connector is determined by us
18、ing the temporal response (time domain) and a function called “GATE” to isolate the connector, which must be connected to the standard precision adapter. Method B Connect the section in measure on network analyser, using if necessary standards accurate adapters, and perform measurement. The VSWR of
19、the two mated connectors is determined by using the temporal response (time domain) and a function called “GATE” to isolate the two mated connectors from the coaxial cable. 6 Requirement The Voltage Standing Wave Ratio (VSWR) does not exceed specified values on the product standard. 7 Detail to be s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN25912212005AEROSPACESERIESELEMENTSOFELECTRICALANDOPTICALCONNECTIONTESTMETHODSPART221VOTAGESTANDINGWAVERATIOVSWREDITIONP1

链接地址:http://www.mydoc123.com/p-451182.html