AS NZS 1851 16-1997 Maintenance of fire protection equipment - Pyrogen fire extinguishing aerosol systems《消防系统和设备的维修 热源灭火气雾剂设备》.pdf
《AS NZS 1851 16-1997 Maintenance of fire protection equipment - Pyrogen fire extinguishing aerosol systems《消防系统和设备的维修 热源灭火气雾剂设备》.pdf》由会员分享,可在线阅读,更多相关《AS NZS 1851 16-1997 Maintenance of fire protection equipment - Pyrogen fire extinguishing aerosol systems《消防系统和设备的维修 热源灭火气雾剂设备》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、AS/NZS 1851.16:1997Australian/New Zealand StandardMaintenance of fire protectionequipmentPart 16: Pyrogen fire extinguishingaerosol systemsAccessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 28 Feb 2006 AVAILABLE SUPERSEDEDAS/NZS 1851.16:1997This Joint Australian/New Zealand Standard wa
2、s prepared by Joint TechnicalCommittee FP/11, Fire Extinguishing Systems. It was approved on behalf of theCouncil of Standards Australia on 25 July 1997 and on behalf of the Council ofStandards New Zealand on 11 July 1997. It was published on 5 September 1997.The following interests are represented
3、on Committee FP/11:Australian Chamber of Commerce and IndustryFire Protection Association, AustraliaCommonwealth Fire Board, AustraliaDepartment of Defence, AustraliaFire Trainers Association of AustraliaInstitute of Security ExecutivesNew Zealand Fire Equipment AssociationNew Zealand Fire Protectio
4、n AssociationScientific Services Laboratory AGAL, Department of Administrative ServicesSociety of Fire Protection Engineers, Australasian ChapterStandards New ZealandTelstra CorporationWaterways Authority (N.S.W.)Review of Standards. To keep abreast of progress in industry, Joint Australian/New Zeal
5、and Standards are subject to periodic review and are kept up to date by the issueof amendments or new editions as necessary. It is important therefore that Standards usersensure that they are in possession of the latest edition, and any amendments thereto.Full details of all Joint Standards and rela
6、ted publications will be found in the StandardsAustralia and Standards New Zealand Catalogue of Publications; this information issupplemented each month by the magazines The Australian Standard and StandardsNew Zealand, which subscribing members receive, and which give details of newpublications, ne
7、w editions and amendments, and of withdrawn Standards.Suggestions for improvements to Joint Standards, addressed to the head office of eitherStandards Australia or Standards New Zealand, are welcomed. Notification of anyinaccuracy or ambiguity found in a Joint Australian/New Zealand Standard should
8、be madewithout delay in order that the matter may be investigated and appropriate action taken.This Standard was issued in draft form for comment as DR 96347.Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 28 Feb 2006 AVAILABLE SUPERSEDEDAS/NZS 1851.16:1997Australian/New Zealand Sta
9、ndardMaintenance of fire protectionequipmentPart 16: Pyrogen fire extinguishingaerosol systemsFirst published as AS/NZS 1851.16:1997.PUBLISHED JOINTLY BY:STANDARDS AUSTRALIA1 The Crescent,Homebush NSW 2140 AustraliaSTANDARDS NEW ZEALANDLevel 10, Radio New Zealand House,155 The Terrace,Wellington 600
10、1 New ZealandISBN 0 7337 1362 9Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 28 Feb 2006 AVAILABLE SUPERSEDEDAS/NZS 1851.16:1997 2PREFACEThis Standard was prepared by the Joint Standards Australia/Standards New ZealandCommittee FP/11 on Fire Extinguishing Systems to provide suitab
11、le requirements for theregular maintenance of Pyrogen fire extinguishing aerosol systems.The objective of this Standard is to provide users of Pyrogen fire extinguishing aerosolsystems with the necessary requirements needed in the regular maintenance of suchsystems.Pyrogen fire extinguishing aerosol
12、 systems may incorporate control and indicatingequipment (CIE) that complies with AS 1603.4, Automatic fire detection and alarmsystems,Part4:Control and indicating equipment, and is installed in accordance withAS 1670, Automatic fire detection and alarm systems System design, installation, andcommis
13、sioning. The maintenance provisions of this Standard therefore overlap those forcontrol and indicating equipment contained in AS 1851.8, Maintenance of fire protectionequipment, Part 8: Automatic fire detection and alarm systems. Where the CIE for asystem forms part of a fire indicator panel (FIP) s
14、erving other zones as well as theprotected enclosure, then maintenance in accordance with AS 1851.8 and this Standardcan be undertaken simultaneously without the need for duplication.This Standard has some variance in text from its sister document, AS 1851.8, due to thechange in the document style p
15、rocedures of Standards Australia.The term informative has been used in this Standard to define the application of theappendix to which it applies. An informative appendix is only for information andguidance. Copyright STANDARDS AUSTRALIA/ STANDARDS NEW ZEALANDUsers of Standards are reminded that cop
16、yright subsists in all Standards Australia and Standards New Zealand publications and software.Except where the Copyright Act allows and except where provided for below no publications or software produced byStandards Australia or Standards New Zealand may be reproduced, stored in a retrieval system
17、 in any form or transmitted by any meanswithout prior permission in writing from Standards Australia or Standards New Zealand. Permission may be conditional on anappropriate royalty payment. Australian requests for permission and information on commercial software royalties should be directed tothe
18、head office of Standards Australia. New Zealand requests should be directed to Standards New Zealand.Up to 10 percent of the technical content pages of a Standard may be copied for use exclusively in-house by purchasers of theStandard without payment of a royalty or advice to Standards Australia or
19、Standards New Zealand.Inclusion of copyright material in computer software programs is also permitted without royalty payment provided such programsare used exclusively in-house by the creators of the programs.Care should be taken to ensure that material used is from the current edition of the Stand
20、ard and that it is updated whenever the Standardis amended or revised. The number and date of the Standard should therefore be clearly identified.The use of material in print form or in computer software programs to be used commercially, with or without payment, or in commercialcontracts is subject
21、to the payment of a royalty. This policy may be varied by Standards Australia or Standards New Zealand at any time.Accessed by ISONET - CHINA STATE BUREAU OF TECHNICAL SUPERVIS on 28 Feb 2006 AVAILABLE SUPERSEDED3 AS/NZS 1851.16:1997CONTENTSPageSECTION 1 SCOPE AND GENERAL1.1 SCOPE . 41.2 REFERENCEDD
22、OCUMENTS 41.3 DEFINITIONS 4SECTION 2 GENERAL REQUIREMENTS2.1 MAINTENANCE 52.2 RECORDS 52.3 PRECAUTIONS. 5SECTION 3 MAINTENANCE PROCEDURES3.1 WEEKLY . 63.2 MONTHLY 63.3 YEARLY . 7SECTION 4 MAINTENANCE DOCUMENTATION4.1 GENERAL 94.2 RECORDSYSTEM 9APPENDIX A SYSTEMLOGBOOKREPORT 10Accessed by ISONET - CH
23、INA STATE BUREAU OF TECHNICAL SUPERVIS on 28 Feb 2006 AVAILABLE SUPERSEDEDAS/NZS 1851.16:1997 4STANDARDS AUSTRALIA/STANDARDS NEW ZEALANDAustralian/New Zealand StandardMaintenance of fire protection equipmentPart 16: Pyrogen fire extinguishing aerosol systemsSECTION 1 SCOPE AND GENERAL1.1 SCOPE This
24、Standard sets out requirements for the regular maintenance of fireextinguishing systems utilizing SOYUZ pyrogenically generated fire extinguishingaerosols, designed and installed in accordance with AS/NZS 4487. Regular maintenanceincludes inspection and testing.The Pyrogen fire extinguishing aerosol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASNZS1851161997MAINTENANCEOFFIREPROTECTIONEQUIPMENTPYROGENFIREEXTINGUISHINGAEROSOLSYSTEMS 消防系统 设备 维修

链接地址:http://www.mydoc123.com/p-449964.html