1、*USACE / NAVFAC / AFCESA / NASA UFGS-32 84 23 (April 2008)-Preparing Activity: USACE SupersedingUFGS-32 84 23 (July 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated March 2008*SECTION TABLE OF CONTENTSDIVISION 32 - EXTERIOR IMPROVEMENTSSECTION 32 84 23UNDERGROU
2、ND SPRINKLER SYSTEMS04/08PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.3 SUBMITTALS1.4 DELIVERY, STORAGE, AND HANDLING1.5 EXTRA MATERIALSPART 2 PRODUCTS2.1 MATERIALS AND EQUIPMENT2.1.1 Standard Products2.1.2 Nameplates2.1.3 Additional Stock2.2 PIPING MATERIALS2.2.1 Copper Tubing and Associated
3、 Fittings2.2.2 Red Brass Pipe and Associated Fittings2.2.3 Galvanized Steel Pipe and Associated Fittings2.2.4 Polyvinyl Chloride (PVC) Pipe, Fittings and Solvent Cement2.2.4.1 PVC Pipe2.2.4.2 PVC Fittings2.2.4.3 Solvent Cement2.2.5 Polyethylene (PE) Plastic Piping2.2.6 Dielectric Fittings2.2.7 Emitt
4、er Hose and Distribution Tubing2.3 SPRINKLER AND EMITTER HEADS2.3.1 Pop-Up Spray Heads2.3.1.1 General Requirements2.3.1.2 Shrubbery Sprinkler Heads2.3.2 Rotary Pop-Up Sprinklers2.3.3 Bubbler Sprinkler Heads2.3.4 Surface Connected Lawn Sprinkler Heads2.3.5 Emitter Heads2.4 VALVES2.4.1 Gate Valves, Le
5、ss than 80 mm 3 Inches2.4.2 Gate Valves, 80 mm 3 Inches and LargerSECTION 32 84 23 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.4.3 Angle Valves, Less Than 65 mm 2-1/2 Inches2.4.4 Angle Valves, 65 mm 2-1/2 Inches and Larger2.4.5 Quick Coup
6、ling Valves2.4.6 Remote Control Valves, Electrical2.4.7 Drain Valves2.4.7.1 Manual Valves2.4.7.2 Automatic Valves2.4.8 Pressure Regulating Master Valve2.4.9 Backflow Preventers2.4.9.1 Pressure Type Vacuum Breaker2.4.9.2 Reduced Pressure Type Backflow Preventers2.5 ACCESSORIES AND APPURTENANCES2.5.1
7、Valve Keys for Manually Operated Valves2.5.2 Valve Boxes and Concrete Pads2.5.2.1 Valve Boxes2.5.2.2 Concrete Pads2.5.3 Pressure Gauges2.5.4 Service Clamps2.5.5 Water Hammer Arresters2.5.6 Emitter Head Accessories2.5.6.1 Strainer2.5.6.2 Pressure Regulator2.5.6.3 Riser Adapters2.5.6.4 Tubing Stakes2.
8、5.6.5 Emitter Outlet Check Valve (Bug Cap)2.5.6.6 Access Sleeve2.5.6.7 Closure Caps2.6 AUTOMATIC CONTROLLERS, ELECTRICAL2.7 ELECTRICAL WORK2.8 CONCRETE MATERIALS2.9 WATER SUPPLY MAIN MATERIALS2.10 INSULATING JOINTSPART 3 EXECUTION3.1 EXAMINATION3.2 INSTALLATION3.2.1 Trenching3.2.2 Piping System3.2.2
9、.1 Cover3.2.2.2 Clearances3.2.2.3 Minimum Slope3.2.3 Piping Installation3.2.3.1 Polyvinyl Chloride (PVC) Pipe3.2.3.2 Soldered Copper Tubing3.2.3.3 Threaded Brass or Galvanized Steel Pipe3.2.3.4 Insulating Joints3.2.3.5 Grooved Mechanical Joints3.2.4 Installation of Valves3.2.4.1 Manual Valves3.2.4.2
10、 Automatic Valves3.2.4.3 Drain Valves3.2.5 Sprinklers and Quick Coupling Valves3.2.6 Installation of Drip Irrigation System3.2.6.1 Emitter Hose3.2.6.2 Emitter Heads3.2.6.3 Tubing Stakes3.2.7 Backflow Preventers3.2.7.1 Pressure Type Vacuum BreakerSECTION 32 84 23 Page 2Provided by IHSNot for ResaleNo
11、 reproduction or networking permitted without license from IHS-,-,-3.2.7.2 Reduced Pressure Type3.2.8 Control Wire and Conduit3.2.8.1 Wires3.2.8.2 Loops3.2.8.3 Expansion and Contraction3.2.8.4 Splices3.2.9 Automatic Controller3.2.10 Thrust Blocks3.2.11 Backfill3.2.11.1 Minimum Cover3.2.11.2 Restorat
12、ion3.2.12 Adjustment3.2.13 Disinfection3.2.14 Cleaning of Piping3.3 FRAMED INSTRUCTIONS3.4 FIELD TRAINING3.5 FIELD TESTS3.5.1 Hydrostatic Pressure Test3.5.2 Leakage Tests3.5.3 Operation Test3.6 CLEANUP- End of Section Table of Contents -SECTION 32 84 23 Page 3Provided by IHSNot for ResaleNo reproduc
13、tion or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-32 84 23 (April 2008)-Preparing Activity: USACE SupersedingUFGS-32 84 23 (July 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated March 2008*SECTION 32 84 23UNDERGROUND
14、 SPRINKLER SYSTEMS04/08*NOTE: This guide specification covers the requirements for underground sprinkler irrigation systems.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate inf
15、ormation.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including t
16、heir organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: Irrigation system requirements depend upon rainfall factors for the project area, plant selections, the quality of growth
17、desired, and budgetary constraints. The area factors will be determined by a registered landscape professional. Reference is made to UFC 3-210-05FA. While the design of a system with pop-up heads may be justified in some geographic areas, bubbler type systems may be required in areas where water con
18、servation methods are being practiced. If source of water supply is from base water main through a service line and water meter, determine amount of water available for irrigation system from static SECTION 32 84 23 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without l
19、icense from IHS-,-,-pressure at point of connection to water main. In many cases, water supply is adequate for short durations only. The amount of water required is determined from the type of turf to be irrigated, climate, terrain, and soil conditions. System piping layout, pipe sizes, and selectio
20、n and spacing of heads and emitters must provide the required amount of water and complete coverage of the irrigated areas. Provide valves to allow irrigation of each area separately.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. T
21、he publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the
22、Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications list
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS3284232008UNDERGROUNDSPRINKLERSYSTEMS 地下 喷水 系统 PDF

链接地址:http://www.mydoc123.com/p-449743.html