ARMY UFGS-31 31 16 21-2008 MESH TERMITE BARRIER《筛网白蚁屏障》.pdf
《ARMY UFGS-31 31 16 21-2008 MESH TERMITE BARRIER《筛网白蚁屏障》.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-31 31 16 21-2008 MESH TERMITE BARRIER《筛网白蚁屏障》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-31 31 16.21 (August 2008)-Preparing Activity: USACE SupersedingUFGS-31 31 16.21 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION TABLE OF CONTENTSDIVISION 31 - EARTHWORKSECTION 31 31 16.21MESH TERMIT
2、E BARRIER08/08PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.3 SUBMITTALS1.4 DELIVERY, STORAGE, AND HANDLING1.5 WARRANTYPART 2 PRODUCTS2.1 MATERIALS2.1.1 Asbestos Prohibition2.1.2 Barrier Mesh2.1.3 AccessoriesPART 3 EXECUTION3.1 SITE VERIFICATION3.1.1 Site Preparation3.1.2 Ground Preparation3.1
3、.3 Verification3.2 INSTALLATION3.3 PROTECTION3.4 VISUAL INSPECTION GUIDE3.5 REPAIRS- End of Section Table of Contents -SECTION 31 31 16.21 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-31 31 16.21 (August
4、2008)-Preparing Activity: USACE SupersedingUFGS-31 31 16.21 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION 31 31 16.21MESH TERMITE BARRIER08/08*NOTE: This guide specification covers the requirements for mesh termite barrier for termit
5、e control. This UFGS is not for a soil treatment.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective pro
6、ject, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Reco
7、mmended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: Termite infestation exists throughout the United States and overseas areas with the exception of Alaska. Mesh termite barriers can be prescribed for installation at all sites where termites are lik
8、ely to establish colonies and make concealed access to wood construction, when it is deemed appropriate and cost effective.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide SECTION 31 31 16.21 Page 2Provided by IHSNot for ResaleNo reproduction or ne
9、tworking permitted without license from IHS-,-,-specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Section
10、s Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcil
11、e references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM A 478 (1997; R 2008) Standard Specification for Chromium-N
12、ickel Stainless Steel Weaving and Knitting WireASTM A 580/A 580M (2006) Standard Specification for Stainless Steel Wire1.2 SYSTEM DESCRIPTION*NOTE: The mesh physically prevents termites from entering the building.*Place the stainless steel mesh across all openings to the building (shrinkage cracks i
13、n concrete slabs and built penetrations in slabs and walls that termites may use). The mesh shall be bonded to the material surrounding the opening using bonding cement, when directed by the Contracting Officer, after determing that a quality bond can be obtained. A correct and complete installation
14、 with no gaps, penetrations or damage to the mesh is essential to achieve and effective barrier. System Installers shall be trained in the behavior of termites and the installation techniques of the mesh barrier.1.3 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 S
15、UBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some SECTION 31 31 16.21
16、 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if th
17、e submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects
18、using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for N
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS313116212008MESHTERMITEBARRIER 筛网 白蚁 屏障 PDF

链接地址:http://www.mydoc123.com/p-449688.html