ARMY UFGS-10 22 19-2010 DEMOUNTABLE MOVABLE PARTITIONS.pdf
《ARMY UFGS-10 22 19-2010 DEMOUNTABLE MOVABLE PARTITIONS.pdf》由会员分享,可在线阅读,更多相关《ARMY UFGS-10 22 19-2010 DEMOUNTABLE MOVABLE PARTITIONS.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 19 (August 2010)-Preparing Activity: USACE SupersedingUFGS-10 22 19 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TABLE OF CONTENTSDIVISION 10 - SPECIALTIESSECTION 10 22 19DEMOUNTABLE MOVABLE
2、PARTITIONS08/10PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Fire-Resistance Rating and Burning Characteristics1.2.2 Acoustical Performance1.2.3 Structural Performance1.2.3.1 Transverse-Load Capacity1.2.3.2 Load-Bearing Capability1.2.3.3 Non-Load Bearing Capability1.2.4 Electrical and Comm
3、unication Capability1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Manufacturer Qualifications1.4.2 Sustainable Design Certification1.5 DELIVERY, STORAGE, AND HANDLING1.6 PROJECT/SITE CONDITIONS1.7 WARRANTYPART 2 PRODUCTS2.1 PARTITION TYPE2.2 MATERIALS AND COMPONENTS2.2.1 Panels2.2.2 Framing System2.2.3 G
4、lass and Glazing2.2.4 Doors and Frames2.2.5 Door Hardware2.2.6 Windows2.2.7 Base Trim2.3 FINISHESPART 3 EXECUTION3.1 EXAMINATION3.2 PREPARATIONSECTION 10 22 19 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.3 INSTALLATION3.3.1 Doors and Wind
5、ows3.3.2 Wall Base3.4 ADJUSTMENTS3.5 CLEANING3.6 PROTECTION- End of Section Table of Contents -SECTION 10 22 19 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 19 (August 2010)-Preparing Activity: USAC
6、E SupersedingUFGS-10 22 19 (May 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION 10 22 19DEMOUNTABLE MOVABLE PARTITIONS08/10*NOTE: This guide specification covers the requirements for demountable and movable partitions.Edit this guide specific
7、ation for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on thi
8、s guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Reques
9、t (CCR).*PART 1 GENERAL*NOTE: Demountable and movable partitions should be used in areas susceptible to future partition rearrangement. Compared to traditional drywall construction, installation of these partitions are faster and eliminate the cost and mess of cutting and fitting carpet and ceilings
10、 around fixed walls. They offer maximum flexibility and reusability to accommodate frequent and quick relocation of work without loss of materials, damage or modification to panels or to adjoining structures such as ceilings, fixed walls and floors. Movable partitions and some demountable partitions
11、 are non-progressive allowing the removal of individual panels from any location without disturbing adjoining units. The partitions are point accessible meaning instant access of SECTION 10 22 19 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
12、panels allows for electrical, telephone and communication lines to be installed quickly and easily. Furniture support is an optional added feature that makes these partition systems similar to furniture systems panels.Partition layouts on the drawings must show partition dimensions, nominal sizes fo
13、r doors, glazing panels, sound-resistance and fire-resistance when required, details and any other information pertinent to partition layouts. Partition layout should be based on module configuration to allow for maximum reusability.Designer should require materials, products, and innovative constru
14、ction methods and techniques which are environmentally sensitive, take advantage of recycling and conserve natural resources. Many manufacturers panels and components are 95 to 100 percent recyclable and reusable.*1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text
15、 of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatical
16、ly place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print
17、process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM C 1396/C 1396M (2009a) Standard Specification for Gypsum BoardASTM E 119 (2009c) Standard Te
18、st Methods for Fire Tests of Building Construction and MaterialsASTM E 413 (2004) Rating Sound InsulationSECTION 10 22 19 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM E 72 (2005) Conducting Strength Tests of Panels for Building Construc
19、tionASTM E 84 (2010) Standard Test Method for Surface Burning Characteristics of Building MaterialsASTM E 90 (2009) Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and ElementsBIFMA INTERNATIONAL (BIFMA)BIFMA X5.6 (2003) Panel SystemsGREENGU
20、ARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70 (2008; TIA 08-1) National Electrical CodeSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor AdvantageUNDERWRITERS LABORATORIES (UL
21、)UL 1286 (2008; R thru 2010) Office Furnishings1.2 SYSTEM DESCRIPTION*NOTE: Performance requirements listed below are optional choices for designer; edit accordingly.*1.2.1 Fire-Resistance Rating and Burning CharacteristicsFire-resistance rating for partitions shall be one-hour _ and in conformance
22、with ASTM E 119. Partition system shall have a Class A (under 25) Flame Spread Rating in conformance with ASTM E 84.1.2.2 Acoustical PerformanceSound-rated partition assemblies shall have a minimum Sound Transmission Coefficient (STC) of 36 42 _. STC range shall be determined in accordance with Soun
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS1022192010DEMOUNTABLEMOVABLEPARTITIONSPDF

链接地址:http://www.mydoc123.com/p-449611.html