1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 39 54 (August 2009)-Preparing Activity: USACE SupersedingUFGS-08 39 54 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2009*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 39 54BLAST RESISTANT DOORS
2、08/09PART 1 GENERAL1.1 REFERENCES1.2 SYSTEM DESCRIPTION1.2.1 Design Requirements1.2.1.1 Static Material Strength1.2.1.2 Dynamic Material Strength1.2.1.3 Structural Member Design1.2.1.4 Dynamic Analysis and Deformation1.2.1.5 Rebound Resistance1.2.2 Blast Effects1.2.2.1 Overpressure1.2.2.2 Overpressu
3、re Direction1.2.2.3 Fragment Resistance1.2.3 Blast Door Operation1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.5 DELIVERY, STORAGE,AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 MATERIALS2.1.1 Concrete and Concrete Reinforcement2.1.2 Structural Tubing2.1.3 Structural Steel2.1.4 Steel Sheet and Strip2.1.5 Fastene
4、rs2.2 HARDWARE2.2.1 Hinges2.2.1.1 General Requirements2.2.1.1 Hinge Description2.2.2 Latching System2.2.2.1 Latching Points2.2.2.2 Latching System Operation2.2.2.3 Latching MechanismSECTION 08 39 54 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,
5、-,-2.2.2.4 Safety Cover2.2.2.5 Cover Plate2.2.2.6 Latches2.2.2.7 Handle2.2.3 Mortise Lock and Latch Set2.2.4 Keying2.2.5 Exit Device2.2.6 Straight Steel Bar Door Pull2.2.7 Padlock2.2.8 Shrouded Padlock2.2.9 Hasp2.2.10 High Security Hasp2.2.11 Shrouded Hasp2.2.12 Door Stop2.2.13 Surface Door Closer2.
6、2.14 Overhead Door Holder2.2.15 Gasket Seal2.2.16 Door Silencer2.2.17 Optical Device2.3 ACCESSORIES2.3.1 Subframe2.3.2 Nameplate2.3.3 Removable Threshold2.3.4 Ramp2.3.5 Self-Rescue Kit2.4 FABRICATION2.4.1 Shop Assembly2.4.2 Mullion2.4.3 Thermal Insulation2.4.4 Shop Finishing2.4.5 Clearance2.5 BLAST
7、DOOR ASSEMBLIES2.5.1 Door _; Steel2.5.1.1 Type2.5.1.2 Overpressure2.5.1.3 Fragment2.5.1.4 Rebound2.5.1.5 Deformation Limits2.5.1.6 Hardware2.5.1.7 Operating Forces2.5.1.8 Accessories2.5.2 Door _; Concrete2.5.2.1 Type2.5.2.2 Overpressure2.5.2.3 Fragment2.5.2.4 Rebound2.5.2.5 Deformation Limits2.5.2.6
8、 Hardware2.5.2.7 Operating Forces2.5.2.8 Accessories2.5.3 Door _; Metal2.5.3.1 Type2.5.3.2 Overpressure2.5.3.3 Rebound2.5.3.4 Hardware2.5.3.5 Operating Forces2.5.3.6 Accessories2.6 TESTS, INSPECTIONS, AND VERIFICATIONS2.6.1 Prototype Static TestSECTION 08 39 54 Page 2Provided by IHSNot for ResaleNo
9、reproduction or networking permitted without license from IHS-,-,-2.6.2 Prototype Blast Test2.6.3 Shop Operating Test2.6.4 Air Leakage Test2.6.5 Sound Rating Test2.6.6 Fire Rating Test and InspectionPART 3 EXECUTION3.1 INSTALLATION3.2 TESTS3.3 MANUFACTURERS FIELD SERVICE- End of Section Table of Con
10、tents -SECTION 08 39 54 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 39 54 (August 2009)-Preparing Activity: USACE SupersedingUFGS-08 39 54 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences
11、 are in agreement with UMRL dated July 2009*SECTION 08 39 54BLAST RESISTANT DOORS08/09*NOTE: This guide specification covers the requirements for manually operated swinging structural steel, reinforced concrete, and hollow metal blast resistant doors.Edit this guide specification for project specifi
12、c requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are
13、 welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.
14、1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference
15、 feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the SECTION 08 39 54 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Reference Wizards Check Reference
16、 feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenc
17、ed. The publications are referred to within the text by the basic designation only.ACI INTERNATIONAL (ACI)ACI 318 (2008; Errata 2008) Building Code Requirements for Structural Concrete and CommentaryACI 318M (2008; Errata 2008) Metric Building Code Requirements for Structural Concrete and Commentary
18、AMERICAN BEARING MANUFACTURERS ASSOCIATION (ABMA)ABMA 11 (1990; R 1999) Load Ratings and Fatigue Life for Roller BearingsABMA 9 (1990; R 2000) Load Ratings and Fatigue Life for Ball BearingsAMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)AISC 325 (2005) Manual of Steel ConstructionAISC 360 (2005) Spe
19、cification for Structural Steel Buildings, with CommentaryAMERICAN IRON AND STEEL INSTITUTE (AISI)AISI SG-971-Spec (1996; Supp 2001) Specification and Commentary for the Design of Cold-Formed Steel Structural Members and Commentary; includes SG-2000-1 Supp 1 to 1996 Spec, dated 2000AMERICAN WELDING
20、SOCIETY (AWS)AWS A2.4 (2007) Standard Symbols for Welding, Brazing and Nondestructive ExaminationAWS A5.4/A5.4M (2006) Stainless Steel Electrodes for Shielded Metal Arc WeldingAWS D1.1/D1.1M (2008; Errata 2009) Structural Welding Code - SteelAWS D1.3/D1.3M (2008; Errata 2008) Structural Welding Code
21、 - Sheet SteelSECTION 08 39 54 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AWS D1.4/D1.4M (2005; Errata 2005) Structural Welding Code - Reinforcing SteelASTM INTERNATIONAL (ASTM)ASTM A 123/A 123M (2009) Standard Specification for Zinc (Hot-
22、Dip Galvanized) Coatings on Iron and Steel ProductsASTM A 153/A 153M (2009) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel HardwareASTM A 242/A 242M (2004; R 2009) Standard Specification for High-Strength Low-Alloy Structural SteelASTM A 307 (2007b) Standard Specification for Ca
23、rbon Steel Bolts and Studs, 60 000 PSI Tensile StrengthASTM A 325 (2009) Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile StrengthASTM A 325M (2009) Standard Specification for Structural Bolts, Steel, Heat Treated, 830 Mpa Minimum Tensile Strength (Metric
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0839542009BLASTRESISTANTDOORS 防爆 PDF

链接地址:http://www.mydoc123.com/p-449583.html