1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 34 53 (August 2008)-Preparing Activity: USACE SupersedingUFGS-08 34 53 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2007*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 34 53SECURITY DOORS AND FR
2、AMES08/08PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 VAULT DOOR UNIT2.2 Doors2.3 Frames and Sills2.4 Day GatePART 3 EXECUTION3.1 INSTALLATION- End of Section Table of Contents -SECTION 08 34 53 Page 1Provided by IHSNot for ResaleNo reproduction or
3、networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 34 53 (August 2008)-Preparing Activity: USACE SupersedingUFGS-08 34 53 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2007*SECTION 08 34 53SECURITY DOORS AND
4、 FRAMES08/08*NOTE: This guide specification covers the requirements for non-security type fire-insulated record-vault doors.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate inf
5、ormation.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including t
6、heir organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publicatio
7、ns are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Art
8、icle. Also use the Reference Wizards Check Reference feature to update SECTION 08 34 53 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the issue dates.References not used in the text will automatically be deleted from this section of the proje
9、ct specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.UNDERWRITERS LABORATORIES (UL)UL 140 (2006;
10、Rev thru Jan 2008) Standard for Relocking Devices for Safes and VaultsUL 155 (2005) Standard Tests for Fire Resistance of Vault and File Room DoorsUL 768 (2006; Rev thru Mar 2007) Standard for Combination Locks1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUB
11、MITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are alread
12、y marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Arm
13、y projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or
14、 other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second
15、bracketed item for Army projects.*SECTION 08 34 53 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control
16、 approval.information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsVault Door UnitDoorsDay GateFrames and SillsHar
17、dwareInstallation drawings which include details of construction, method of anchorage and type and location of the following: Vault Door Units, Hardware, Frames and Sills, and Day GateSD-03 Product DataVault Door UnitDoorsDay GateFrames and SillsManufacturers descriptive data and catalog cuts. Prepr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYUFGS0834532008SECURITYDOORSANDFRAMES 安全门 门框 PDF

链接地址:http://www.mydoc123.com/p-449582.html