1、MIL-T-60895 (MU) 19 April 1968 MILITARY SPECIFICATION ! TELESCOPE, PANORAMIC: M117A1 1. SCOPE 1.1 This specification covers the Panoramic Telescope, M117A1 which _- . - employs a counter mechanism. _. . i. I I_ -_ 2. APPLICABLE DOCUMENTS I .a .2,1 The following documents, of the issue in effect on d
2、ate of invitation for bids or request for proposal, form a part of this specifi- cation to the extent specified herein. SPECIFICATIONS Mil it ar y MIL-o- 1: ,x Optical Components for Fire Control Instruments; General Specification Governing the Manufacture and Inspcton of Fire Control Materiel; Gene
3、ral Specifi- cation Governing the Manufacture and Inspection of Parts, Equipment and Tools for Ordnance Materiel; Packaging of Inspection Equipment, Supply and Maintenance of ML-F-13926 . , .I MIL-P-14232 WIT,- 145607 - STANDES Mi 1 i tar y MIL-STD-105 Sampling Procedure and Tables for MIL-STD-109 .
4、 Quality Assurance Terms and Definitions MIL-STD- 202 Test Methods for Electronic and Electrical Inspection by Attributes Component Parts DRAWINGS U,S. Amy, Frankford Arsenal - .- I. , P7560400 -. Telescope, Panoramic Provided by IHSNot for ResaleNo reproduction or networking permitted without licen
5、se from IHS-,-,-d MIL-T-bO75 12 = 77779Ob 0391719 2 MIL-T- 60895 (MU) PACKAGING DATA SHEET 105559 74 Packaging of Telescope, Panoramic: M117A1 (Copies of specifications, standards, drawings and packaging data sheets required by suppliers in connection with specific procurement functions should be ob
6、tained from the procuring activity or as directed by the contracting officer.) 3. REQUIREMENTS 3.1 Fabrication,- The telescope shall be manufactured in accordance with Drawing F7660400 and drawings pertaining thereto. 3.2 .General specification.- The contractor shall be responsible for adherence to
7、and compliance with the requirements of Specification MIL-F-13926 specified below. tion and this specification, this specification shall take precedence. Should any conflict exist between the general specifica- (a) Order of precedence. (b) Dimensions and tolerances. (c) Inorganic protective surface
8、finishes. (d) Electrical and electronic assemblies. (e) Part identification and marking. ( f) Workmanship, 3.3 Environmental. 3.3.1 Storage temperatures.- The telescope shall show no evidence of physical failure or damage subsequent to being exposed to and thermally stabilized at -80“ and +160F. 3.3
9、.2 Extreme operating temperatures.- The telescope shall meet the applicable requirements of 3.8.2.6 and 3.9 while exposed to and thermally stabilized at -40“ and +150F. 3.3.3 Standard temperature.- Unless otherwise specified, the tele- scope shall meet the following requirements while exposed to and
10、 thermally stabilized at a temperature between 60“ and 90F. 3.3.4 Vibration.- The telescope shall show no evidence of physical failure or damage and shall meet the following requirements, except 3.7.1.1, after being subjected to a vibration of 30 I: 5 cycles per second at an amplitude of 1/16 inch,
11、1/8 f 1/64 inch total excursion, for a period of 5 minutes i 5 seconds (see 3.7.1.1). 3.4 Sealing. 3.4.1 Pressure (optical system),- The entire interior area of the optical assembly shall be capable of withstanding an internal pressure of 5 f 0.10 pounds per square inch (psi) for a period of 5 minut
12、es with no evidence of leakage, _I - 1 2. - -. _ . . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-60895 12 3999706 03Lt1920 9 W MIL-T-60895 (Mu) 3.4.2 Pressure (counterbox area),- Apply an internal pressure of 2.0 + .25 pounds per square inc
13、h (psi) of dry nitrogen for a period of 3 minutes to each telescope. There shall be no evidence of leakage, 3.5 Cleanliness.- The telescope shall meet the cleanliness requirements of Specification MIL-0-13830 and there shall be no more than 2 particles of dirt visible on the reticle. excess of the a
14、rea equivalent to a size 10 dig. on other surfaces which interferes with observation or adversely affects image quality, The area of each particle shall not be in There shall be no dirt 3.6 Orientation The requirements of 3.7 to 3.8.3.3.2 inclusive shall be met with the telescope orientated in the f
15、ollowing position: (a) (b) (c) (d) (e) (f) The main telescope tube vertical as determined by the keys on each side. The reset counter indicating 3200 mils and the azimuth counter set at O000 (Black). The gunners aid counters set at zero. The line of sight horizontal. The elbow assembly centered betw
16、een the swing stops within 2“. Knob 8587442 indicating INDIRECT (out of detent). 3.7 Accuracy. 3.7.1 Collimation. 3.7,l.l Pre-vibration.- Prior to meeting the requirements of 3.3.4, the line of sight shall be perpendicular to the locating keyways within 5.0 mils, 3.7.1.2 Post-vibration.- Subsequent
17、to meeting the requirements of 3.3.4, the line of sight shall remain within 0.25 mil of the azimuth position established in 3.7.1.1. 3.7.2 Image tilt.- When checked at 1600 mil increments in azimuth through two full revolutions in each direction, the image of a vertical target line shall be vertical
18、 within one degree of arc. This requirement shall also be met with the elbow assembly positioned against each of the swing stops, 3.7.3 Parallelism of.retcle and image.- When checked at 1600 mil increments in azimuth through two full revolutions in each direction, the vertical reticleline shall be p
19、arallel to the image of a vertical target line within 30 minutes of arc. the elbow assembly positioned against each of the swing stops at each azimuth setting. This requirement shall also be met with .3,7.4 the limits of -0.75 and -1.0 diopter. Eyepiece focus.- The eyepiece focus shall be fixed betw
20、een Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T- 60895 (MU) 3.7.5 Parallax.- Parallax in the center of the field shall not exceed 0.1 mil when viewing a target at 80 meters f 1.0 meter. 3.7.6 Resolution.- Resolution on the optical axis shal
21、l be 10.0 seconds of arc or less when using an auxiliary telescope of at least 3 power having an entrance pupil of at least 0.4 inch. Resolution shall consist of detectable line structure and proper line count in all four meridians. Variation in focus between meridians shall not exceed 0.25 diop- te
22、rs as measured at the telescope eyepiece. 3.7.7 Reticle accuracy.- The angle formed by the graduations at the outer extremity of the reticle shall be within 0.25 mil of the value indicated on the reticle drawing. 3.8 Performance. 3.8.1 Elevation mechanism 3.8.1.1 Excursion range.- Rotation of the el
23、evation knob shall cause the line of sight to elevate and depress a minimum of 300 mils from the position specified in 3.6(d). 3.8.1.2 Plumb travel.- With the line of sight in coincidence with a vertical target line, the line of sight shall track the target within 0.5 mil when elevated 300 mils, dep
24、ressed to 300 mils, then elevated to zero elevation. 3.8.2 Azimuth mechanism. 3.8.2.1 Azimuth error.- Error at azimuth readings, taken in 800 mil increments through two full revolutions shall not exceed 1.0 mil excluding back1 as h. 3.8.2.2 Deflection error.- Rotating the gunners aid knob to indicat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT608951968TELESCOPEPANORAMICM117A1M117A1 全景 望远镜 PDF

链接地址:http://www.mydoc123.com/p-448815.html