1、MIL-T-bO207 57 W 777770b 007b7b 7 W A-39-09 y MIZ-T- 60207 (MU) 26 February 1965 SUPERSEDING FA(FC) -143 28 April 1961 MILITARY SPEC IF ICATION TRANSFORMER, POWER, STEP-DOWN: 10525910 1. SCOPE 1.1 This specification covers one type of transformer (Type Designation: TF5RX0122) used for Voltage regula
2、tion in the Gun Direction Computer: M18, 2, APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of imitation for bids or request for proposal, form a part of this specification Manufacturing Processes and Inspection of Sampling Procedure and Tables for Inspection Quality
3、 Assurance Terms and Definitions Test Methods for Electronic and Electrical by Attributes Component Parts DRAWINGS U. S. Army Munitions Command C10525910 Transformer, Power, Step-Down / 7 THIS DOCUMENT CONTAINS i0 PAGES Provided by IHSNot for ResaleNo reproduction or networking permitted without lic
4、ense from IHS-,-,-NIL-T-60207 57 m 7777706 007b7b7 7 m MIL-T- 60207 (MU) PACKAGING DATA SHEET MIL-P-l4232/P10525910 Packaging of Transformer, Power, Step-Down (Copies of specifications, standards, drawings, and packaging data sheets, re- quired by the suppliers in connection with specific procuremen
5、t functions should be obtained from the procuring activity or as directed by the contracting officer.) 3. REQUIREMENTS 3.1 Fabrication.- The transformer (Type Designation TF5RX0122) shall be manufactured in accordance with Drawing C10525910 and drawings pertaining thereto. 3.1.1 -Gase.and potting.-
6、The case shall be of molded flame resistant fiber glass and resin construction and shall be potted with a self-extinguishing, semi- flexible epoxy resin compound. 3.2 General specifications.- The transformer shall meet the requirements of MIL-T-27 for its particular type designation or classificatio
7、n. former shallialso meet the specified requirements of MIL-C-46357. The trans- (a) Installation of hardware (b) Securing leads (c) Soldering (d) Solvent vapor deereasing (e) Marking ink for non-metals (f) Application of decals (g) Twenty-four hour test procedure for transformers and inductors 3.2.1
8、 Order of precedence,- Should any conflict occur between the general specifications and the detailed specification the order of precedence shall be as follows: (a) Detailed specification (b) MIL-C-46357 (c) MIL-T-27 3.3 Environmental service conditions. 3.3.1 Vibration.- The transforher shall be sub
9、jected to a simple harmonic motion having an amplitude of 0.03 inch (0.06 inch total excursion), The fre- quency shall be varied uniformly from 10 to 55 cycles per second (cps) and return to 10 cycles. The motion shall be applied to the transformer for a period of 10 minutes in each direction of the
10、 3 mutually perpendicular axes (total of 30 minutes), relative to its normal operational position, Subsequent to vibration, the transformer shall not be damaged or adversely affected and shall meet the requirements of 3.4. This cycle shall be traversed in 1 minute 5 15 seconds. 3.3.2 Shock,- The tra
11、nsformer shall withstand 3 shock impulses in each of 3 mutually perpendicular directions. shall be 5 gravity units (Gs), 1 milliseconds. versely affected and shall meet the requirements of 3.4, 2. The acceleration of the shock impylses Pulse duration of each impulse shall be 11 Subsequent to shock t
12、he item shall not have been damaged or ad- - CI=- i , Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- -. - MIL-T-60207 57 W 7779706 0076770 5 3. MIL-T-60207 (MU) I- 3.3.3 Temperatures. 3.3.3.1 OP eratin.- The transformer shall meet the requirements
13、of 3.4 while exposed to an atmosphere with a relative humidity (RH) up to 97% at a temperature of 1350F. 3.3.4.2 Non-operating.- The transformer shall meet the requirements of 3.4 after exposure to (and when thoroughly dried) an atmosphere with a RH of 100 percent including condensation, for a-perio
14、d of 4 hours. 3.3.5 Fungus resistance.- The transformer shall show no evidence of damage and shall meet the requirements of 3.4, after being inoculated with the composite spore suspension specified in MIL-F-13926 and incubated at an ambient tempera- ture of between 77OF and 84OF with a RH of 97 a ba
15、rometric pressure of 28 to 32 inches of mercury; and a RH up to 90%. 3.4.1 Primary.- The primary rating shall be 208 volts, 3 phase, 400 cps, on terminals 1-2-3. 0.10 amp! Wye connection. ohms maximum, and 4.25 ohms minimum, Maximum no load loss, 10 watts; maximum no load current D.C. resistance sha
16、ll be between the limits of 5.75 3.4,2 Secondaries.- The rating of the secondaries shall be in accordance with the following tabulation, Voit (Line hps Volts (no load) Con- DC Resistance Working Teminal to Line) (nns) Max. Min. nection Max. Min, Volts Max. 4-5-6 15.5 0.77 16.4 15.6 Delta 0.32 0.22 3
17、0 7-8-9 6.3 0.64 6.63 6.37 Delta 0.14 0.10 11 10-11-12 ,24.3 1.7 25.5 24.5 Delta 0.26 0.18 45 13-14-15 20,6 0.96 21.8 20.8 Delta 0.45 0.31 35 16 Electrostatic Shield 17 Core ground 3.4.3 Insulation resistance,- Thp insulation resistance shall be 10,000 megohms minimum between each winding and the ot
18、her windings and mounting inserts. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-T-b0207 57 777906 007IJ73 7 MIL-T-60207 (MU) windings, electro-static shield and mounting inserts shall be as tabulated below: 3.4.4 Dielectric strength,- The die
19、lectric strength at sea level, between Terminal 1-2-3 4-5-6 7-8-9 10 -1 1-12 13-14-15 16 17 (Core ground) Dielectric Strength (rms) 850 500 500 500 500 500 500 3.4.5 Induced voltage.- The induced voltage shall be 416 volts rms, 800 cps, 3 phase, applied to tedinals 1-2-3. 3.4.6 Electro-static shield
20、.- The shieldings ratio shall be 4 to 1 or greater between any two windings at a frequency of 20 Kc. 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility far inspection.- Unless otherwise specified in the con- tract or purchase order, ehe supplier is responsible for the performance of all inspection r
21、equirements as specified herein. supplier may utilize his own facitities or any comercial laboratory acceptable to the Government. The Government reserves the right to perform any of the in- spections set forth in the specification where such inspections are deemed ne- cessary to assure supplies and
22、 services conform to prescribed requirements. Except as otherwise specified, the 4.1.1 General provisions.- The component inspection requirements of MIL- F-13926 form a part of the Quality Assurance Provisions of this specification. Definitions of inspection terms shall be as listed in MIL-STD-109.
23、4.2 Inspection provisions. 4.2.1 Submission of Product.- Unless otherwise specified herein, or by the contracting officer, inspection lot size, lot formation and presentation of lots shall be in accordance with “SuDmission of Product“ as specified in MIL-STD- 105 4.2.2 Examinations and tests.- Excep
24、t where otherwise specified hyrein, * components and sub-assemblies shall be inspected- in accordance with the “inspec- tion provisions for components and sub-assemblies and the Sampling Plan Tables contained in MIL-F-13926. Examinations and tests related to Section 3 herein shall be performed in ac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT602071965TRANSFORMERPOWERSTEPDOWN1052591010525910 降压 变压器 PDF

链接地址:http://www.mydoc123.com/p-448811.html