ARMY MIL-T-44243 A-1990 TENT SECTIONS TENT EXTENDABLE MODULAR PERSONNEL (TEMPER)《人员模块可伸长帐篷材料(回火)》.pdf
《ARMY MIL-T-44243 A-1990 TENT SECTIONS TENT EXTENDABLE MODULAR PERSONNEL (TEMPER)《人员模块可伸长帐篷材料(回火)》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-T-44243 A-1990 TENT SECTIONS TENT EXTENDABLE MODULAR PERSONNEL (TEMPER)《人员模块可伸长帐篷材料(回火)》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-T-4LI243A 3 W 977770b 04b2003 W 23 November 1990 SUPERSEDING MIL-T-44243 30 September 1986 MILITARY SPECIFICATION TENT SECTIONS, TENT, EXTENDABLE, MODULAR, PERSONNEL (TEMPER) This specification is approved for use by all Departments and Agencies of i - the Department of Defense. 4. 1. SCOPE 1.1
2、Scope. This specification covers the tent sections of an extendable, modular, personnel, frame supported tent. * 1.2 Classification. Tent sections, liners, floors, vestibule, vestibule door, vestibule container- and tent cover shall be classified as follows (see 6.2) : Items 1. - 2. - 3. - 4. - 5. -
3、 6. - 7. - 8. - 9. - 10. - End section Window section (temperate) Door sect ion ( desert /tropical) Window section (desert/tropical) Door section (temperate) Tent fly (16 feet) Tent fly (8 feet) End section liner (temperate) End section liner (desert/tropical) Intermediate liner (temperate) pertinen
4、t data which may be used in improving this document should be addressed to: U.S. Army Natick Research, Development, and Engineering Center, Natick, MA 01760-5014 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by Petter. AMSC N/A FSC
5、 8340 DISTRIBUTION STATEMENT A. Approved for publie release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Items 11. - 12, - 13. - 14. - 15. - 16, - 17. - IO. - 19. - 20. - 21. - 22. - 23. - 24. - 25. - 26. - Intermediate
6、 liner (desert/tropical) Tent floor (single ply) 8 feet, 24 feet and 40 feet Tent floor (insulated) Vestibule w/door Vestibule floor (single ply) Vestibule floor (insulated) Part it ion Tent cover Vestibule container Tent pin container Modesty curtain Plenum, end wall, 16 feet Plenum, extendable, 16
7、 feet Sliding blackout curtain Plenum, side entrance, 16 feet Vestibule door cap * 4 2. APPLICABLE DOCUMENTS 2.1 Government documents. * 2*1*1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein.
8、 Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS FEDERAL A-A-50083 - Bag, Plastic, Folded Garment TT-P-595 -
9、 Preservative Coating, Canvas ( General Use) DDD-L-20 - Label: For Clothing, Equipage, and Tentage, PPP-B-601 - Boxes, Wood, Cleated-Plywood PPP-B-636 - Boxes, Shipping, Fiberboard PPP-B-640 - Box, Fiberboard, Corrugated, Triple-Wall STANDARDS FED ERAL FED-STD-191 - Textile Test Methods FED-STD-751
10、- Stitches, Seams and Stitchings 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-44243A 3 999990b 04b2005 1 MILITARY MIL-STD-105 - Sampling Procedures and Tables for Inspection MIL-STD-129 - Marking for Shipment and Storage MIL-STD-147 - Pall
11、etized Unit Loads MIL-STD-731 by Attributes - Quality of Wood .Members for Containers and Pallets (Unless otherwise indicated, copies of federal and military specifications, standards, and handbooks are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philade
12、lphia, PA 191 1 1-5094. - * 2.1.2 Other Government documents, drawings, and publications. The following 4 other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues 5 are those cited in the solicitation.
13、DEPARTMENT OF THE ARMY FIELD MANUAL FM 10-16 - General Repair of Tents, Canvas and Webbing (Copies of documents required by contractors in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting activity.) DRAWINGS U.S. ARMY N
14、ATICK RESEARCH, DEVELOPMENT, AND ENGINEERING CENTER 5-4-3342 5 -4 -334 9 5-4-3350 5-4-335 1 5-4-3352 5-4-3353 5-4-3354 5-4-3355 5-4-3356 5-4-3357 5-4-3358 5-4-3359 5-4-3360 5-4-336 1 5-4-3362 5-4-3363 5 -4 -33 64 5-4-3365 5-4-3366 - Hitch Pin Clip and Holder - Tent Sections, Tent, Extendable, Modula
15、r, Personnel ( Temper) - End Section - Door Section (Desert/Tropical) - Window Section (Desert/Tropical) - Tent Flies - Screen Door - Vent Flap - Window Flap - Beckets - Erection Instructions - Tent Cover - Weather Seal Flaps - Purlin Flaps - Door Section (Temperate) - Window Section (Temperate) - E
16、nd Section Liner (Temperate) - End Section Liner (Desert/Tropical) - Intermediate Liner (Temperate) 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-4q243A 3 H 999990b 04b200b 3 H 5-4-3367 5-4-3369 5-4-3370 5-4-3371 5-4-3372 5-4-3373 5-4-3374
17、5-4-3375 5-4-3376 5-4-3377 5-4-3378 5-4-3379 5-4-3380 5-4-3381 5-4-3382 5-4-3383 5-4-3384 5-4-3386 5-4-3387 5-4-3388 5-4-3389 5-4-3390 5-4-3391 5-4-3368 5-4-36 13 5-4-36 14 5-4-36 16 5-4-3618 5-4-3615 5-4-3617 5-4-36 19 5-4 -3 620 5-4-3621 5-4-3981 5 -4-3982 5-4-3983 5 -4 -3985 5-4-3984 MIL-T-44243A
18、 - Intermediate Liner (Desert/Tropical) - Tent Floor (Single Ply) - Tent Floor (Insulated) - Vestibule - Vestibule Door - Vestibule Floor (Single Ply) - Vestibule Floor (Insulated) - Vestibule/Pin Container - Adapter - Adapter - Vent Flap - Window and Flap - Sleeve - Door/Window - Stove Pipe Flap -
19、End Liner - Door/Window Section Liner (Temperate) - Door - Stovepipe Shield Flap - Door/Window Section Liner (Desert/Tropical) - Vent Flap - Flap - Suspension Strap - Partition - Modesty Curtain - Plenum, End Wall - Body, End Wall - Cover, Plenum - Extension 12 Inch Dia, End Wall - Plenum, Extendabl
20、e, 16 Feet - Body, Extendable - Plenum, Side Entrance, 16 Feet - Sliding Blackout Curtain - Body, Side Entrance - Exterior, 12 Inch Dia, Side Entrance - Vestibule Door Cap - Tent Floor, 24 Feet (Single Ply) - Tent Floor, 40 Feet (Single Ply) (Copies of drawings are available from the U.S. Army Natic
21、k Research, Development, and Engineering Center, ATTN: STRNC-UX, Natick, MA 01760-5014.) * 2.2 Non-Government publications. The following documents form a part of this Unless otherwise specified, the issues document to the extent specified herein. of the documents which are DoD adopted are those lis
22、ted in the issue of the DODISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DODISS are the issues of the documents cited in the solicitation (see 6.2). 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-
23、,-,-r MIL-T-44243A 3 I 9997906 O462007 5 AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D 3574 - Standard Methods of Testing Flexible Cellular Materials - Slab, D 3951 - Standard Practice for Commercial Packaging Bonded, and Molded Urethane Forms (Application for copies should be addressed to the
24、 American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103-1187.) (Non-Government standards and other publications are normally available from the organizations that prepare or distribute the documents. These documents P also may be available in or through libraries or oth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT44243A1990TENTSECTIONSTENTEXTENDABLEMODULARPERSONNELTEMPER 人员 模块 伸长 帐篷 材料 回火 PDF

链接地址:http://www.mydoc123.com/p-448555.html