ARMY MIL-T-44222 A-1991 TENT LINER SECTIONS INSULATED (TEMPER)《绝缘帐篷衬里(回火)》.pdf
《ARMY MIL-T-44222 A-1991 TENT LINER SECTIONS INSULATED (TEMPER)《绝缘帐篷衬里(回火)》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-T-44222 A-1991 TENT LINER SECTIONS INSULATED (TEMPER)《绝缘帐篷衬里(回火)》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、9 MIL-T-44222A 83 m 9999906 0468905 I W I- a a, - MIL-T-44222A 1 March 1991 SUPERSEDING MIL-T-44222 3 April 1986 MILITARY SPEC IF ICAT ION TENT LINER SECTIONS; INSULATED (TEMPER) This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE AND CLASSIF
2、ICATION 1.1 Scope. This specification covers insulated tent liner sections and covers for use with the tent, expandable, modular, personnel. 1.2 Classification. Tent liner sections shall be of the following types as specified (see 6.2). Type I - End section Type II - Intermediate section Type III -
3、Intermediate door section 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents ar
4、e those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (see 6.2). Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be used in improving this document should
5、be addressed to: U.S. Army Natick Research, Development, and Engineering Center, Natick, MA 01760-5017 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 8340 DISTRIBUTION STATEMENT A. Approved for public release
6、; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-44222A SPE C IF I CAT IONS FEDERAL DDD-L-20 PPP-B-601 PPP-B-636 STANDARDS FEDERAL FED-STD-751 MIL I TARY MIL-STD-105 MIL-STD-129 MIL-STD-147 MIL-STD-731 ( Un 1 e s s o
7、 t ii e rw i s e - Label: for Clothing, Equipage, and Tentage, - Boxes, Wood, Cleated-Plywood - Boxes, Shipping, Fiberboard (General Use) - Stitches, Seams and Stitchings - Sampling Procedures and Tables for Inspection - Marking for Shipment and Storage - Palletized Unit Loads - Quality of Wood Memb
8、ers for Containers and Pallets by Attributes stand Desk, indicated, copies of federal and military specifications, .ards, and handbooks are available from the Standardization Documents Order Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.1.2 Other Government documents, drawings, an
9、d publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWINGS U.S. ARMY NATICK RESEARCH, DEVELOPMENT, AND ENGINEERING CENTER 5 -4 -
10、33 5 9 5-4 -4 12 7 5-4-4128 5-4-4129 5 -4 -4 1 3 O 5-4-4131 5-4-4132 5-4-4133 Tent Cover End Section Liner (Insulated) End Liner (Insulated) Door Section Liner (Insulated) Intermediate Door Section Liner (Insulated) Intermediate Section Liner (Insulated) Flap Assemblies Vent Sleeve 2 Provided by IHS
11、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-P MIL-T-44222A 83 = 9999906 0468907 5 d d MIL-T-44222A 5 -4 -41 34 - Lanyard Assemblies 5 -4 -4 1 3 5 - Toggle Lanyard 5-4 -4 1 3 6 - Light Support Assembly 5-4 -41 3 7 - Hook, Chain, “S“ (Copies of drawings are avail
12、able from the U.S. Army Natick Research, Development, and Engineering Center, ATTN: STRNC-UX, Natick, MA 01760-5017.) PUBLICATION U.S. DEPARTMENT OF THE ARMY FIELD MANUAL FM 10-16 - General Repair of Tents, Canvas and Webbing (Copies of documents required by contractors in connection with specific a
13、cquisition functions may be obtained from the contracting activity or as directed by the contracting activity.) 2.2 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of the documents which are DOD
14、adopted are those listed in the issue of the DODISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DODISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) D 3951 - Standard Practic
15、e for Commercial Packaging (Copies may be obtained from the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103-1187.) (Non-Government standards and other publications are normally available from the organizations that prepare or distribute the documents. These docum
16、ents also may be available in or through libraries or other informational services.) 2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applic
17、able laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.21, a sample shall be subjected to first article inspection (see 6.31, in accordance with 4.3. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted with
18、out license from IHS-,-,- MIL-T-44222A 83 W 9999906 0468908 7 MIL-T-442 2 2 A 3.2 Materials and components. Materials and components shall be as specified on the applicable drawings. Materials not definetely specified shall be of the quality normally used by- the contractor provided that the complet
19、ed item complies with all the provisions of this specification. It is encouraged that recycled material be used when practical as long as it meets the requirements of this specification. 3.3. Construction. Construction shall conform to the drawings listed in section 2 and be as specified herein. 3.3
20、.1 Stitching machine. 3.3.1.1 Types of stitching. All stitch types shall conform to FED-STD-751 as follows: For all stitching except binding - Type 301, 5 to 7 stitches per inch For binding or stitching - Type 401, 5 to 7 stitches per inch appear on the outside of cover or pile fastener tape indicat
21、ed by “Z“ on drawings - Chain portion of stitching shall not 3.3.1.2 Thread breaks. Thread breaks in stitching shall be overstitched not less than 1 inch at each break on stitch type 301 and not less than 1-1/2 inches at each break on type 401 stitching. Thread breaks on type 401 stitching may be ov
22、erstitched with stitch type 301. Thread breaks noted during inspection shall be repaired by overstitching the existing stitching starting from a distance of 1 inch before the break, across the defective area, to a distance of 1 inch beyond the break. The ends of repair stitching are not required to
23、be backstitched. 3.3.1.3 Stitching ends. Stitching at the ends shall be overstitched not less than 1 inch on stitch type 301 except where ends are turned under in a hem, held down by other stitching. Where 301 stitching is performed automatically on stitch patterns such as box, box with cross-stitch
24、, “W“ stitching, or straight line tacking, at least three tying, overlapping, or back stitches shall be used to secure the ends of stitching. 3.3.1.4 Skipped stitches. Two or more skipped stitches occurring consecutively in stitch type 301 shall be overstitched not less than 1 inch on each side of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT44222A1991TENTLINERSECTIONSINSULATEDTEMPER 绝缘 帐篷 衬里 回火 PDF

链接地址:http://www.mydoc123.com/p-448553.html