1、MIL-T-L3g5B 12 = 777770b 0275327 2 W MIL-T-l3458B(MF) 16 April 1968 SUPERSEDING MIL-T-l3458A(MU) 18 October 1963 MILITARY SPECIFICATION TELESCOPES PANORAMIC: M12A7 SERIES 1. SCOPE l.-l This specification covers a series of panoramic telescopes, hereinafter referred to as telescopes. These telescopes
2、 are essentially identical except for reticle pattern and the zero azimuth setting (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids, or request for proposal, form a part of this specifi- cation to the extent specified herein. SPECI
3、FICATIONS Military MIL-0-13830 MIL-F-13926 MIL-P-14232 MIL-1-45607 Optical Components of Fire Control Instruments: General Specification Governing the Manufacture, Assembly, and Inspection of cation Governing the Manufacture and Inspection of Parts, Equipment and Tools for Army Materiel; Packaging a
4、nd Packing of Inspection Equipment, Supply and Maintenance of Fire Control Materiel: General Specifi- STANDARDS Mil it ary MIL-STD-105 MIL-STD- 109 DRAWINGS U.S. Army, Frankford Arsenal - F7687260 F7687263 F8228975 F10555616 I_ Sampling Procedures and Tables for Quality Assurance Terms and Definitio
5、ns Inspection by Attributes Telescopes, Panoramic: M12A7CY M12A7DY Telescope, Panoramic: M12A7F Telescope, Panoramic: M12A7K and M12A7R Set-up and Operating Instructions for M12A7GY M12A7H, M12A7QY and M12A7S Panoramic Telescopes M12A7 Series FSC 1240 A Provided by IHSNot for ResaleNo reproduction o
6、r networking permitted without license from IHS-,-,-MIL-T-l3458B(MU) PACKAGING DATA SHEETS 3444632 3444U33 7687260 7687261 7687262 7687263 8213036 8213037 . 8213035 . Telescope, Panoramic M12A7K Telescope, Panoramic M12A7H Telescope, Panoramic M12A7C Telescope, Panoramic M12A7D Telescope, Panoramic
7、M12A7G Telescope, Panoramic M12A7F Telescope, Panoramic M12A7Q Telescope, Panoramic M12A7R Telescope, Panoramic M12A7S (Copies of specifications, standards, drawings and packaging data sheets required by suppliers in connection with specific procurement functions should be obtained from the procurin
8、g activity or as directed by the contracting office.) 3. REQUIREMENTS 3.1 Materials.- Materials shall be in accordance with drawings, material specifications and general specifications forming a part of this specification. 3.2 Fabrication.- The telescope shall be manufactured in accordance with draw
9、ings applicable to the telescope specified in the contract or order and drawings pertaining thereto. 3.3 General specifications.- The contractor shall be responsible for adherence to, and compliance with, the following requirements of MIL-0-13830 and MIL-F-13926: 3.3.1 MIL-0-13830 (a) Cleanliness (b
10、) Illuminated reticle 3.3.2 MIL-F-13926 (a) Order of precedence (b) Dimensions and tolerances (c) Inorganic protective surface finishes (d) Part identification and marking (e) Workmanship 3.4 Environmental. 3.4.1 Storage temperature.- The telescope shall show no evidence of physical failure and shal
11、l meet all performance requirements of this speci- fication at a standard ambient temperature of 60“ to 90F after having been exposed to and thermally stabilized at ambient temperatures of -80 and +160“F. - _-.- I - 2. Provided by IHSNot for ResaleNo reproduction or networking permitted without lice
12、nse from IHS-,-,-MIL-T- 13458B(MU) 3.4.2 Operating temperatures.- The telescope shall meet the require- ments o? 3.20 while exposed to and thermally stabilized at ambient tempera- tures of -40“ and +150“F. 3.4.3 Sealing.- The telescope shall show no evidence of leakage when subjected to Procedure I
13、of the rain test specified in MIL-F-13926. 3.4.4 Vibration.- There shall be no evidence of physical failure and the telescope shall meet the following requirements of this specification after being subjected to a vibration of 30 cycles per second at an amplitude of 1/16 inch (1/8 inch total excursio
14、n) for a period of 5 minutes +: 15 second 3.5 Cleanliness.- The telescope shall meet the cleanliness requirements specified in MIL-0-13830. There shall be no more than two particles of dirt visible on the surfaces of the reticle. The area of each particle shall not be in excess of the area of a size
15、 ten dig. There shall be no other dirt within the telescope which interferes with observation or adversely affects image quality. 3.6 Orientation.- The telescope shall meet the applicable requirements of this specification with the horizontal locating surface of the shank horizontal and the line of
16、sight positioned in azimuth as indicated in Figure I for the telescope model specified. M12A7C M12A7D M12A7G M12A7H M12A7Q M12A7S 5- t MI2A7F M12A7R I ! i , i AZIMUTH . LO CAT ING PIN L i 1 EYEPIECE FIGURF, I ZERO AZIMUTH SETTINGS IN RELATION TO MIMUTH LOCATING PIN 3. Provided by IHSNot for ResaleNo
17、 reproduction or networking permitted without license from IHS-,-,-MIL-T-I3458B(MU) 3.7 Collimation. 3.7.1 Elevation.- With the telescope positioned as specified in 3.6 and the elevation indexes indicating zero, the line of sight shall be horizontal within O. 5 mil. 3.7.2 Azimuth.- With the telescop
18、e positioned as specified in 3.6, the azimuth scales shall indicate zero within 0.5 mil. 3.7.3 Open sight.- With the telescope positioned as specified in 3.6, the line of sight of the open sight shall be horizontal within 10 mils and parallel in azimuth to the optical line of sight within 10 mils. 3
19、.8 Image ti1.t.- The image of a vertical target shall be vertical within 1.0 degree of arc at any azimuth setting. 3.9 Parallelism of reticle and image.- With the horizontal locating surface of the shank horizontal, the center vertical line of the reticle shall be parallel to the image of a vertical
20、 target within 30 minutes at any azimuth setting. .3.10 Plumb travel.- With the horizontal locating surface.of the shank horizontal and coincidence established with a vertical target at 300 mils elevation, the line of sight shall not deviate more than 1.0 mil from the target through 600 mils travel
21、in depression. The total lateral spread shall not exceed 1.5 mils. 3.11 Backlash.- Backlash shall not exceed 1.0 mil in the elevation worm mechanism; nor exceed 0.5 mil in the azimuth worm mechanism. 3.12 Vertical displacement.- Vertical displacement, due to reversing the azimuth motion by means of
22、the azimuth worm knob, shall not exceed 0.5 mil. 3.13 Level travel.- With the horizontal locating surface of the shank horizontal and coincidence established with a horizontal target, the line . of sight shall not deviate more than 1.0 mil from the target through two full revolutions of the head. az
23、imuth worm to rotate the head in azimuth. This requirement shall be met by utilizing the 3.14 Azimuth error.- The error in any azimuth reading shall not exceed 1.5 mils including backlash. 3.15 Scales. 3.15.1 Deflection.- The ratchet on the adjustable micrometer index shall hold the index in coincid
24、ence with each graduation of the deflection scale on the worm shoe within 0.2 mil. 3.15.2 Elevation.- With the elevation worm knob indicating zero, the index on the ring shall be in coincidence with the zero line on the head within one half the width of the graduation line. f Provided by IHSNot for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILT13458B1968TELESCOPESPANORAMICM12A7SERIESM12A7 系列 全景 望远镜 PDF

链接地址:http://www.mydoc123.com/p-448468.html