1、r - MIL-S-44195A 54 9997906 0488049 - 9 q -zI MIL-S-44195A 30 July 1991 SUPERSEDING MIL-S-44195 30 September 1985 MILITARY SPJEIFICATIN SHELTER, TACIICAL, EXPANDULE, “D-SIDE This specification is approved for use by all Departments and Agencies of the Department of Defense. “ii -1 4.r“ 1. CCOPE 1.1
2、Scow, This doc=ument covers a rigid wall, two-side expandable shelter constructed of aluminum faced, mmtallic honeycanb sandwich panels, and meting the International organization for Standarcil zation (IS) Cargo Container specification in the transport mode. closed (container imde) are: feet. Approx
3、iniate dimensions, when expmded (shelter mode) are: height 8 feet, width 22 feet and length 20 feet. Nominal dimencions when height 8 feet, width 8 feet and length 20 2. APPLICABLE- 2.1 Government documents. 2.1.1 sec! ifications, standards, and handbooks. The following specifica- unless otherwise s
4、pecified, the issues of these do-105 - Sampling procedures and Tables for Inspection MIL-SID-810 - Enviromntal Test Methods and Engineering MIL-SID-907 - Engineering and Design Criteria for Shelters, MIL-SlD-1595 - Qualification of Aircraft, Missile and Aerospace MIL-STD-2219 - Fusion Welding for Ae
5、rospace Applications by Attributes Guidelines a Expandable and Non-Expandable * Fusion Welders (unless othsrwise indicated, copies of federal and military specifications, standards, and handbooks are available fmm the Standardi zation Dccurnents rder Desk, wiilding 4D, 700 Robbins Avenue, Philadelph
6、ia, PA 19111-5094.) 2.1.2 other Government documents. drawinus. and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. the issues are those cited in the solicitation. Unless otherwise specified, DRAWINGS US
7、ARMY NATICK RESl?ARCH AND DEVELIIPMENT lA3RAmRIES 5-4-3118 - Shelter Assembly, Itio Side Ekpndable - 60 amp 5-4-3201 - Shelter Assembly, Side Expndable - 100 amp (Copies of drawings required by contractors are available fran the U.S. Army Natick Research, Developnt, and Engineering Center, ATI“: Nat
8、ick, MA 01760-5017.) this docment to the extent specified herein. the issues of the d0c;Uments which are KID adopted are those listed in the issue of the KIDISS cited in the solicitation. the issues of the doIruments not listed in the DODISS are the issues of the documents cited in the solicitation
9、(see 6.2). sI“C-UX, 2.2 Non-Goverriment publications. The following documents form a part of Unless othemise specified, Unless otherwise specified, 2 Licensed by Information Handling ServicesMIL-S-44195A International (IS) Freight Container, mification for IS 1161 Series 1 - Freight Containers-Corne
10、r Fittings, Specification 1496/1 Series 1 - Freight Containers Specification Testing, Part I, General Cargo Containers (Application for copies should be addressed to the American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018.) AMENCAN s0CIE;Ty FOR TESTING AND MATERIALE (ASM)
11、E 864 - Surface Preparation of Aluminum Allays to be Adhesively Bonded in Honeycomb Shelter Panels E 865 - Standard Specification for Structural Film Adhesives for Honeycomb Sandwich Panels E 866 - Standard Specification for Corrosion-Inhibiting PrW for Aluminum Allays to be Adhesively Bonded in Hon
12、eycomb Shelter Panels E 874 - standard Practice for Adhesive Bonding of Aluminum Facings to Nomtallic Honeyconb Core for Shelter Panels E 990 - Core-Splice Adhesive Film for Honeycanb Sandwich Shelter Panels E 1091 - Non-Metallic Hmeycomb Core for Use in Shelter Panels (Application for copies should
13、 be addressed to the American Society for (Non-Government standards and other publications are normally available the conductor having a current carrying capacity of at least 100 amps at 125% imibient taprature. mounted on the exterior of the shelter. Conductors running fran panel board circuits to
14、fixtures or receptacles shall be inclosed in rigid conduit or shall be specified flexible cable for the eqamiable portion of the shelter. The current carrying capcity of the conductors shall be 20 anp minimum, based upon an ambient temperature of 125% and NM: rating procedures. All circuit breakers
15、used in the system shall be bolt-on type and have a minirmmi interrupting capacity of lO,OOO amps RMS syrmietrical. The ais feed cables will terminate in a connector 3.5.8.6 Cablinq. Flexible cables shall be used to feed all relocatable These cables shall be as indicated on the lighting fixtures and
16、 receptacles. drawings. 3.5.8.7 Switches. 3.5.8.8 Groundi nq. All noncurrent carrying metal cmponents shall be solidly gmunded using the green grouiid wire within the wiring system as indicated on the drawings. Switches used shall be as indicated on the drawings. 3.5.8.9 Fbceptacles. a. Electrical m
17、wer service entrance. The electrical pcnierservice entrame shall be as shown on the drawings. 7 Licensed by Information Handling ServicesMIL-S-44195A b. Convenience outlets. The shelter shall contain duplex convenience outlets as indicated on the drawings. All outlets shall be electrically grounded.
18、 c. Air conditioning. Power for heating and cooling equipumt shall be provided fran the distrikation panel in the shelter to an elecrtrical connector mounted in the service entrance recessed pan on the outside of the shelter, as indicated on the drawings. d. Ekkemal outlets. Paver distribution shall
19、 be provided fmn the distribution panel box in the shelter to outlets muntd in the service entrance messed pan on the outside of the shelter as indicated on the drawings. 3.5.8.10 Camninications. The shelter shall have four (2 pairs) circuits through the wall telephone and intercan utility connectio
20、n3 terminating in four protected terminals inside and outside the shelter, as indicated on the drawings. 3.5.8.11 -1s. Wls provided with the shelter shall be readily accessible to personnel when the shelter is in both the container and shelter configuration. 3.6 Performance characteristics. 3.6.1 Fl
21、oor loads. The shelter floor shall be capable of supporting a uniform load of 65 pounds per sguare foot. The shelter floor shall be capable of supporting a concentrated load of 2,000 pounds over a 4 square foot area at the center of the floor. The floor shall also be capable of supporthg a point loa
22、d of 125 pounds per square inch. any permanent deformation of the floors or cause any deflection that interfenxi with proper shelter operation, when tested asspecified in 4.6.5. load of 40 pounds per square foot anci a personnel load of 660 pounds static over 2 quam feet when tested as specified in
23、4.6.6. Wds shall not cause 3.6.2 Roof loads. The roof assembly of the shelter shall withstand a sncm 3.6.3 bor lads. Container doors shall be tested to withstand the following loads without deformation of impairment of function: capable of supnorting 200 pounds applied to the door at the edge opposi
24、te the hinge pivot line with the door open to approximately 90 degrees when tested as specified in 4.6.7. a. Static duor (hinge) load: The doors, frames and hardware shall be b. Wind gust door (stop) load: The doors, frames and hardware shall withstand a wind gust of 60 mh in any direction when the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILS44195A1991SHELTERTACTICALEXPANDABLETWOSIDE 双面 扩展 战术 掩蔽部 PDF

链接地址:http://www.mydoc123.com/p-447978.html