ARMY MIL-PRF-71229 D-2011 MOUNT GUN 120MM.pdf
《ARMY MIL-PRF-71229 D-2011 MOUNT GUN 120MM.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-71229 D-2011 MOUNT GUN 120MM.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、 Comments, suggestions, or questions on this document should be addressed to U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact i
2、nformation can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. AMSC N/A FSC 1015 INCH-POUND MIL-PRF-71229D (AT) 6 January 2011 SUPERSEDING MIL-PRF-71229C (AT) 23 August 2001 PERFORMANCE SPECIFICATION MOUNT, GUN,
3、120MM This specification is approved for use by the U.S. Army Tank Automotive Research, Development and Engineering Center (TARDEC), Research, Development and Engineering Command (RDECOM), Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense.
4、1. SCOPE 1.1 Scope. This gun mount is used with the 120MM Gun Cannon, M256, and in the Abrams Series Tanks. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sec
5、tions of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification,
6、 whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in
7、the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-71229D 2 COMMERCIAL ITEM DESCRIPTIONS A-A-52624 - Antifreeze, Multi Engine Type DEPARTMENT OF DEFENSE SPECIFICATIONS DoD-C-70429 - Cannon, 120MM Gun: M256
8、 (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the ext
9、ent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI/(NFPA) T2.13.7 - Hydraulic Fluid Power - Petroleum Fluids - Prediction of Bulk Moduli (Copies of these document
10、s are available from www.ansi.org or ANSI Customer Service Department, 25 W. 43rd Street, 4th Floor, New York, NY 10036.) ASTM INTERNATIONAL ASTM D1655 - Standard Specification for Aviation Turbine Fuels (DoD Adopted) ASTM D4175 - Standard Terminology Relating to Petroleum, Petroleum Products, and L
11、ubricants (DoD Adopted) ASTM G21 - Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi (DoD Adopted) (Copies of these documents are available from www.astm.org or ASTM International, P.O. Box C700, West Conshohocken, PA 19428-2959.) SAE INTERNATIONAL SAE AMS 3054 -
12、 Oil, Lubricating, Low Temperature for -55 C (-67 F) Service (DoD Adopted) SAE J300 - Engine Oil Viscosity Classification (DoD Adopted) SAE J312 - Automotive Gasolines SAE J313 - Diesel Fuels SAE J1447 - Fire-Resistant Fluid Usage in Hydraulic Systems of Off-Road Work Machines Provided by IHSNot for
13、 ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-71229D 3 (Copies of these documents are available from www.sae.org or SAE Customer Service, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) 2.4 Order of precedence. Unless otherwise noted herein or in the contrac
14、t, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article.
15、 When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.3. 3.2 Design, materials, and manufacturing processes. The design, materials, and manufacturing processes shall be in accordance with the manufacturers standard practice as long as all articles su
16、bmitted to the Government fully meet the operating, interface, support and ownership, and operating environment requirements specified herein. 3.3 Operating requirements. The gun mount, completely assembled and lubricated, shall operate without chatter, erraticness, or binding in all ranges of eleva
17、tion, depression, and temperatures, without special aids under all operating conditions and as specified herein. 3.3.1 Hydraulic system. The gun mount shall be filled with hydraulic fluid, bled, and refilled until all air and moisture are eliminated. The initial and subsequent filling of the hydraul
18、ic system shall be with hydraulic oil and filtered through a 5-micron filter. Prior to and after mechanical gymnastication (see 3.3.1.1), a 100 ml 5 ml sample volume of oil shall be drawn from the hydraulic system. The sample volume of oil shall be free of all metallic or abrasive particles that may
19、 cause damage to the inner surface of the operating mechanisms. These particles shall not exceed 600 microns in diameter (0.024 in.) except for nonmetallic lint and fibers, where a maximum of 35 particles between 600 and 3000 microns in greatest dimensions are allowed per one sample (see 4.5.1). 3.3
20、.1.1 Mechanical gymnastication. Each gun mount shall be capable of mechanical gymnastication at elevations ranging from 0 to 35 degrees with a tolerance of 2 degrees without evidence of erratic movement (see 4.5.1.1). 3.3.1.2 Hydraulic leakage - mechanical gymnastication. During and immediately foll
21、owing mechanical gymnastication, no more than 15 drops of oil shall accumulate at any location in a three minute period (see 4.5.1.2). 3.3.2 Counter-recoil (CTRR) time. The maximum CTRR time shall be 0.4 seconds at 0 2 degrees elevation, and 2.0 seconds at 35 2 degrees elevation (see 4.5.1.1). Provi
22、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-71229D 4 3.3.3 Proof firing. Each gun mount shall be proof fired (see 6.6.1) or a sample shall be proof fired in accordance with the sampling plan (see 6.2) when simulation testing (see 6.6.2) is in
23、effect (see 4.5.3). 3.3.4 Simulation testing. Simulation testing followed by proof firing according to a sampling plan may be used in lieu of 100 percent (%) proof firing providing the simulator is qualified as specified in 6.3. Simulation testing, providing this election is desired and approved, sh
24、all be conducted on each gun mount according to the simulation test provisions specified in 4.5.4 without evidence of malfunction or failure. 3.3.5 Recoil cycle. When firing (see 6.6.3) at 100% and 113 4% acceptance levels (see 6.6.4), the recoil cycle travel (in inches) and total recoil cycle time
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF71229D2011MOUNTGUN120MMPDF