ARMY MIL-PRF-49170B-1997 OPTICAL IMAGER SU-97 UA SU-97A UA AND SU-97B UA.pdf
《ARMY MIL-PRF-49170B-1997 OPTICAL IMAGER SU-97 UA SU-97A UA AND SU-97B UA.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-49170B-1997 OPTICAL IMAGER SU-97 UA SU-97A UA AND SU-97B UA.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、METRICMIL-PRF-49170B(CR)19 MAY 1997SUPERSEDINGMIL-I-49170A(ER)11 June 1982PERFORMANCE SPECIFICATIONOPTICAL IMAGER, SU-97/UA, SU-97A/UA, AND SU-97B/UAThis performance specification is approved for use by USACECOM, Department of theArmy, and is available for use by all Departments and Agencies of the
2、Department of Defense.1. SCOPE1.1 Scope. This performance specification covers one type of common module with threechangeable models; Optical Imager, SU-97/UA, SU-97A/UA, and SU-97B/UA.2. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified in sections 3 and 4 of thiss
3、pecification. This section does not include documents in other sections of this specification orrecommended for additional information or as examples. While every effort has been made toensure the completeness of this list, document users are cautioned that they must meet allspecified requirements d
4、ocuments cited in sections 3 and 4 of this specification, whether or notthey are listed.2.2 Government documents.2.2.1 Handbooks. The following handbooks form a part of this document to the extentspecified herein. Unless otherwise specified, the issues of this documents are those listed in theissue
5、of the Department of Defense Index of Specifications and Standards (DoDISS) andsupplement thereto, cited in the solicitation (see 6.2). Handbooks are for guidance only andtherefore are not mandatory.AMSC N/A FSC 5855DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Ben
6、eficial comments (recommendations, additions, deletions) and any pertinent data which maybe of use in improving this document should be addressed to: HQ, USA Communications-Electronics Command, ATTN: AMSEL-LC-LEO-E-EP, Fort Monmouth, NJ 07703 by using theStandardization Document Improvement Proposal
7、 (DD Form 1426) appearing at the end of thisdocument or by letter.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-49170B(CR)2HANDBOOKSDEPARTMENT OF DEFENSEMIL-HDBK-454 - Standard general requirements for electronicequipment(Unless otherwise i
8、ndicated, copies of the above handbooks are available from theStandardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA19111-5094.)2.2.2 Other Government documents, drawings, and publications. The following otherGovernment documents, drawings, and publications form a par
9、t of this document to the extentspecified herein. Unless otherwise specified, the issues are those cited in the solicitation.Drawings listed below are identified to ensure accurate interface of the item produced under thisperformance specification with existing hardware.DRAWINGSUS ARMY COMMUNICATION
10、S-ELECTRONICS COMMANDSM-D-806993 - Optical Imager SU-97/UASM-D-772258 - Optical Imager SU-97A/UASM-D-969555 - Optical Imager SU-97B/UA(Copies of specifications, standards, drawings, and publications required by contractors inconnection with specific procurement functions should be obtained from the
11、procuring activity oras directed by the contracting officer.)2.3 Non-Government publications. The following documents form a part of this documentto the extent specified herein. Unless otherwise specified, the issues of the documents which areDoD adopted are those listed in the issue of the DoDISS c
12、ited in the solicitation. Unlessotherwise specified, the issues of documents not listed in the DoDISS are the issues of thedocuments cited in the solicitation (see 6.2).AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ANSI PH 3.35-1977 - Method of designating and measuring focallengths and distances of p
13、hotographic lenses.ANSI PH 3.29-1979 - Method of designating and measuringapertures and related quantities pertaining to photographic objectives and projection lenses.ANSI/ASQC Z1.4 - Sampling procedures and Tables for inspection.Provided by IHSNot for ResaleNo reproduction or networking permitted w
14、ithout license from IHS-,-,-MIL-PRF-49170B(CR)3(Application for copies should be addressed to American National Standards Institute, Inc.1430 Broadway, NY, NY 10018)2.4 Order of precedence. In the event of a conflict between the text of this document andthe references cited herein, the text of this
15、document takes precedence. Nothing in thisdocument, however, supersedes applicable laws and regulations unless a specific exemption hasbeen obtained.3. REQUIREMENTS3.1 First article. When specified in the contract (see 6.2) the contractor shall furnish firstarticle units for inspection (see 4.2).3.2
16、 Materials. The contractor shall select the materials, but the materials used shall befully capable of meeting all of the operational and environmental requirements specified herein.The materials specified in the applicable drawings are recommended, but are not mandatory.Selection criteria of the cl
17、ass, grade or type part shall be that the material will be able to performits intended function when it is assembled. Verification of the supplier meeting the overallperformance requirements shall be the governing acceptance standard. Recovered materials shallbe used to the maximum extent possible.3
18、.3 Description. The Optical Imager SU-97/UA, SU-97A/UA, and SU-97B/UA, referredto herein as the imager, consists of thermally compensated optical elements which focus the IRenergy from a mechanical scanner onto the detector array of an infrared system. The threemodels differ in their internal config
19、uration but are identical in performance and externalconfiguration. In system usage, they are, and must be, completely interchangeable.3.3.1 Design. The imager shall meet the form, fit, function and interface requirements ofthis specification.3.3.2 Weight. The weight of the imager shall be 318 grams
20、 or under as weighed by a scalewith an accuracy of 1% or better.3.3.3 Dimensions. The imager shall meet the dimensions and dimensional tolerances ofdrawings SM-D-806993, SM-D-772258 or SM-D-969555 to ensure proper physical mating andoperation of the items built under this specification with the exis
21、ting hardware.3.4 Components. The number of components comprising the imager shall be held to aminimum consistent with meeting the performance requirements. In this regard, drawings are tobe considered as a non-binding guide only.Provided by IHSNot for ResaleNo reproduction or networking permitted w
22、ithout license from IHS-,-,-MIL-PRF-49170B(CR)43.5 Performance characteristics.3.5.1 Effective Focal Length (EFL). The EFL of the imager in the 7.6 to 11.75 micrometerspectral region shall be 67.8, 0.7 millimeters as defined by ANSI PH 3.35, paragraph 4.3.5.2 f/number. The f/number of the imager sha
23、ll be f/1.6 or faster, set by the clearaperture of the first lens element (see Figure 3), as defined by ANSI PH 3.29, paragraph 2.6.3.5.3 Linear Distortion. The geometric (linear) distortion of the imager shall be between 0to -3 percent at the edge of the field.3.5.4 Modulation transfer function (MT
24、F). The MTF of the imager shall not be less thanthe MTF given in Figure 1 as measured in a flat-field focal plane and parallel to surface A inFigure 2. Perform 4.5.4 for acceptance.3.5.5 Relative Illumination (RI). The RI of the imager at f/2.0 shall not be less than 60percent at the edge of the fie
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF49170B1997OPTICALIMAGERSU97UASU97AUAANDSU97BUAPDF

链接地址:http://www.mydoc123.com/p-447334.html