《ARMY MIL-P-53132-1993 POWER PLANT POWER UNIT TACTICAL QUIET GENERATOR SET TRAILER MOUNTED 3 KW THROUGH 60 KW GENERAL SPECIFICATION FOR《动力装置或动力设备 3-60千瓦挂车载式战术电源静音发电机组 一般性技术规范》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-P-53132-1993 POWER PLANT POWER UNIT TACTICAL QUIET GENERATOR SET TRAILER MOUNTED 3 KW THROUGH 60 KW GENERAL SPECIFICATION FOR《动力装置或动力设备 3-60千瓦挂车载式战术电源静音发电机组 一般性技术规范》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-P-53132 W 9997906 1953423 T5L W I INCH-POUND I MIL-P-53132 (ME) , 4 November 1993 SUPERSEDING (See 6.12) MILITARY SPECIFICATION POWER PLANT/POWER UNIT, TACTICAL QUIET GENERATOR SET, TRAILER-MOUNTED 3kW THROUGH 60kW GENERAL SPECIFICATION FOR This specification is approved for use within the USA B
2、elvoir Research, Development and Engineering Center, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for tactical, quiet, trailer-mounted power plants from 3 kilowatts (kW) t
3、hrough 60kW; 400 hertz (Hz), 50/60 Hz and 60 Hz alternating current (ac) and tactical, quiet, trailer-mounted power units from 5kW through 60kW; 400 Hz, 50/60 Hz and 60 Hz ac. The power plant shall consist of two Department of Defense (DoD) tactical, quiet, diesel-fueled, skid-mounted generator sets
4、, various equipment, brackets and hardware mounted on one or more modified Government-furnished trailer chassis. The power unit shall consist of one DoD tactical, quiet, diesel-fueled, skid-mounted generator set, various equipment, brackets and hardware mounted on one modified Government- furnished
5、trailer chassis. 1.2 Classification. The power plants/power units shall be of the following sizes and modes. Size Mode I 50/60 Hz Mode II 400 Hz Mode III 60 Hz 3 3kW, Mode III - Power plant only 5 5kW, Mode III 10 10kW, Mode II and III 15 15kW, Mode I and II 30 30kW, Mode I and II 60 60kW, Mode I an
6、d II 1 Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: USA BELVOIR RDE CTR, ATTN SATBE TSE, FT BELVOIR VA 22060- 5818 by using the Standardization Document Improvement Proposal (DD Form 1426) ap
7、pearing at the end of this document or by letter. AMSC N/A FS C 6115 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2. APPLICABLE DOCUMENTS 2.1 Government documents. 2
8、.1.1 Specifications and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDIS
9、S) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS FEDERAL A-A- 5505 7 - Panels, Wood/Wood Based: Construction and Decorative. PPP-B- 6 O 1 - Boxes, Wood, Cleated Plywood. PPP-B- 6 3 6 - Box, Shipping, Fiberboard. PPP- P- 2 91 - Paperboard, Wrapping and Cushioning. PPP-T-
10、76 - Tape, Pressure Sensitive Adhesive, PackaginglPaper. MIL I TARY MIL- P- 116 - Preservation, Methods of. MIL-E-10062 - Engine, Preparation or Shipment and Storage of. MIL-B-22191 - Barrier Material, Transparent, Flexible, Heat Sealable MIL-G-28554 - Generator Sets, Mobile Electric Power and Suppl
11、emental MIL-A-46153 - Antifreeze, Ethylene Glycol, Inhibited, Heavy duty, Equipment; Packaging of. Single Package, Type I (Tactical), Class 2 (Utility). (See Supplement 1 for list of associated specification sheets). STANDARDS MILITARY MIL-STD-105 MIL-STD-129 MIL-STD-209 MIL-STD-454 MIL-STD-642 MIL-
12、STD-705 MIL-STD-810 MIL-STD-889 MIL-STD-1186 MIL - STD - 14 7 4 MIL-STD-1791 - Sampling Procedures and Tables for Inspection by - Marking for Shipment and Storage. - Slinging and Tiedown Provisions for Lifting andTying Down Military Equipment. - Standard General Requirements for Electronic Equipment
13、. - Identification Marking o Combat and Tactical Transport Vehicles. - Generator Sets, Engine one increment shall include data from the noisiest position. Additionally, the noise level at the typical operating position shall be provided as dB(A) level. Failure to comply with MIL-STD-1474 or nonconfo
14、rmance to 3.6 shall constitute failure of this test. 4.7 Transportability tests. 4.7.1 Tiedown provisions. The tiedown provisions shall be tested in accordance with MIL-STD-209 to prove conformance to 3.9.1. Inability to meet the requirements of 3.9.1 shall constitute failure of this demonstration.
15、4.7.2 Slinqinq provisions. The slinging provisions shall be tested in accordance with MIL-STD-209 to prove conformance to 3.9.2. Inability to meet the requirements of 3.9.2 shall constitute failure of this demonstration. 4.7.3 Rail impact test. The first article power plant/power unit shall be teste
16、d in accordance with MIL-STD-810 to prove conformance to 3.9.4. Inability to meet the requirements of 3.9.4 shall constitute failure of this test. 4.7.4 Air transport test. The power plant/power unit shall be tested in accordance with MIL-STD-1791 to prove conformance to 3.9.3. Inability to meet the
17、 requirements of 3.9.3 shall constitute failure of this test. 4.7.5 Hiqhway transport test. The power plant/power unit shall be tested to conform to 3.9.5. Inability to meet the requirements of 3.9.5 shall constitute failure of this test. 4.7.5.1 Road test. The first article power plant/power unit s
18、hall undergo 10 road cycles as defined in 6.14. The set shall be in operating condition and all fluids shall be at normal level, except the fuel tank shall be one-half fuel. Each set shall be towed by an appropriate vehicle. TM 608.1 of MIL-STD-705, shall be conducted at the beginning of the test at
19、 the end of every two road cycles. These tests shall be conducted at rated load only. Prior to assembly and at the conclusion of the road test, the generator sets shall be subjected to an audio noise tests (see 4.6.2). Any rough handling damage (see 6.4.11, and nonconformance to 3.9.5 shall constitu
20、te a failure. 4.8 Inspection of packaqinq. 4.8.1 First article pack inspection. The first article pack (see 6.7) shall be examined for the applicable defects listed in the quality assurance provisions of MIL-G-28554 and for the additional defects listed in 4.8.2.3 of this specification. The presence
21、 of one or more defects shall be cause for rejecting the first article pack. Any defect(s) shall be corrected and the first article pack re-examined. 4.8.2 Quality conformance inspection of packaqinq. 12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-
22、,-MIL-P-53L32 9999906 1953435 773 MIL-P-53132 (ME) 4.8.2.1 Unit of product. For the purpose of inspection, a completed pack prepared for shipment shall be considered a unit of product. 4.8.2.2 Samplinq. Sampling for examination shall be.in accordance with O MIL-STD-105. 4.8.2.3 Examination. Sample p
23、ower plants/power units, selected in accordance with 4.8.2.2, shall be examined for the applicable defects listed in the quality assurance provisions of MIL-G-28554 and the following defects. Presence of one or more defects shall be cause for rejection. 112. 113. 114. 115. 116. 117. 118. 119. 120, 1
24、21. 122. - 123, A Preservation not as specified. 5.2.1 Bottom of the generator set not protected with plywood shields as specified. 5.2.1 Cooling system not preserved as specified. 5.2.1 Box type housing not as specified. 5.3.1 Box type housing not secured to generator set or trailer bed. 5.3.1 Meta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILP531321993POWERPLANTPOWERUNITTACTICALQUIETGENERATORSETTRAILERMOUNTED3KWTHROUGH60KWGENERALSPECIFICATIONFOR

链接地址:http://www.mydoc123.com/p-446578.html