1、27-3 7-47 MIL-L-51272C 13 M 777770b 0333677 1 MIL-L-51292C( EA) 25 September 1987 SUPERSEDING MIL-L-51292B( MU) 9 June 1970 MILITARY SPECIFICATION LAUNCHER AND GRENADES, SMOKE: HC AND WP, 176 This specification is approved for use within U.S. Aw Chemical Research, Development and Engineering Center,
2、 Department of the Army, and is available for use by all Departments -and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of launcher for dispensing grenades . 2. APPLICABLE DOCUMENTS 2.1 Government documents . 2.1.1 Specifications and .standards . The f
3、ollowing specifications and stan- dards form a part; of this specification to the extent specified herein. otherwise specified, the issues of these documents shall be those listed in that issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited
4、in the solicitation. Unless SPECIFICATIONS FEDEFULL NN-P-530 - TT-1-572 - PPP-B-621 - PPP-F-320 - PPP-T-66 - Plywood, Flat Panel. Wood Preservative: Water-Repellant. Boxes, Wood, Nailed and Lock-Corner. Fiberboard: Tape , Packaging, Vinyl Plastic Film. Corrugated and Solid, Sheet Stock ( Container G
5、rade) and Cut Shapes. : Beneficial comments (recommendations , additions , deletions) and any perti- : : nent data which may be of use in improving this document should be addressed: : to: Commander, U.S. Army Chemical Research, Development and Engineering : : Center, ATTN: SMCCR-SPT-S, Aberdeen Pro
6、ving Ground, MD 21010-5423 by using: : the self-addressed Standardization Document Improvement Proposal (DD Form : : 1426) appearing at the end of this document or by letter. AMSC N/A FSC - 1330 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. /- THIS DOCUMENT CONTAI
7、NS 9 PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-L-51292C ( EA) MILITARY MIL-C-2439 - Containers, Ammunition, Fiber, Spirally Wound. MIL-G-12327 - Grenade, Hand, Smoke, HC, AN-M8. STANDARDS MILITARY MIL-STD-105 - Sampling Procedures an
8、d Tables. for Inspection by Attributes. MIL-STD-129 - Marking for Shipment and Storage. MIL-STD-709 - Ammunition Color Coding. MIL-STD-1168 - Ammunition Lot Numbering. P. 2.1.2 Drawings and publications. The following drawings and publications form a part of this specification to the extent specifie
9、d herein. wise specified, the issues shall be those in effect on the date of the solicita- .1 Unless other- x DRAWINGS U.S. ARMY CHEMICAL RESEARCH, DEVELOPMENT AND ENGINEERING CENTER 13-12-1 - Launcher and Grenades, Smoke: HC and WP, M176. 13-12-19 - Packing for Grenade Launcher, m76. 13-12-20 - Mar
10、king Diagram for Grenade Launcher, M176. 13-12-21 - Palletization for Grenade Launcher , 176. PUBLICATIONS U.S. ARMY CHEMICAL RESMCH, DEVELOPMENT AND ENGINEERING CENTER R14-9 - Inspect ion Standard for Fluoroscopic or Radiographic Evalua- tion of; Launcher and Grenade, HC and WP, 176. ( Copies of sp
11、ecifications, standards , drawings , and publications required by contractors in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting 2.2 Order of precedence. In the event of a conflict between the text of this specificatio
12、n and the references cited herein ( except for associated detail specifications, specification sheets or MS standards) , the text of this specification shall take precedence. shall supersede applicable laws and regulations unless a specific exemption has been Obtained. Nothing in this specification,
13、 however, 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-T- - MIL-L-51272C 13 7777906 0333683 T . MIL-L-51292C ( EA) 3 0 REQUIRESIENTS 3.1 kterials and components. 3.1.1 Materials. All materials cited on Drawing 13-12-1 and on the subsid- iary dra
14、wings shall conform to the specifications thereon or to the specific characteristics set forth on the drawings. 3.1.2 Components. All components shall conform to the specifications and drawings listed on Drawing 13-12-1 and subsidiary drawings, as applicable. AN-M8 grenades produced more than 90 day
15、s prior to assembly into launchers shall be tested within 90 days prior to assembly into launchers and meet the functional requirements of MIL-G-12327. The 3.2 Assembly. The launcher shall be assembled as shown on Drawing 13-12-1. 3.3 Radiographic or fluoroscopic evaluation. The launcher shall be ra
16、dio- graphed or fluoroscoped for missing components, in accordance with 4.4.4.1. 3.4 Leakage. The launcher shall not leak air when submerged in water at a temperature of 170“ + 10“F, for a period of 30 to 35 seconds when tested in accordance with 4.4.6.2. 3.5 Functioning. The launcher shall eject th
17、e grenades to an average impact distance of 100 to 170 feet based on the average of the entire sample that functioned. However, no grenade shall impact at a distance of less than 80 feet. separate on or before impact and the grenades shall ignite and emit a smoke cloud. above the horizontal, and the
18、 front underside of the launcher shall be 77 + 1 inch above the average impact area, 100 to 170 feet down range. in accordance with 4.4.4.3. In addition, the two components of the sabot (holder and cover) shall Angle of elevation for firing test stand shall be 33 t1/2 degrees Test shall be 3.6 Low t
19、emperature. The launcher shall function subsequent to a condition- ing period of 48 + 1 hours at a temperature of -25“ + 2“F, when tested in accor- dance with 4.3.3.i. - 3.7 High temperature. tioning period of 48 + 1 hours at a temperature of 125“ + 5“F, when tested in accordance with 4.3.3T2. The l
20、auncher shall function subsequent to a condi- - 3.8 Water immersion. The launcher shall function subsequent to being sub- merged in water at ambient temperature for 60 + 5 minutes and then removed from the water and fired after 24 to 25 hours, in accordance with 4.3.3.3. 3.9 Preproduction. Prior to
21、the start of regular production, a preproduc- tion sample of launchers shall be produced in accordance with this specifica- tion for examination and test (see 4.3). 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.10 Workmanship. The launcher shal
22、l be free from foreign matter and damage which could affect functioning . 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the con- tract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified h
23、erein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements speci- fied herein, unless disapproved by the Government. right to perfom any of the inspections set forth in the
24、 specification where such inspections are deemed necessary to assure supplies and s.ervices conform to prescribed requirement s. The Government reserves the 4.1.1 Responsibility for compliance. All items must meet all requirements of sections 3 and 5. The inspection set forth in this specification s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILL51292C1987LAUNCHERANDGRENADESSMOKEHCANDWPXM176XM176HC WP 发烟 手榴弹 发射器 PDF

链接地址:http://www.mydoc123.com/p-445621.html