1、Comments, suggestions, or questions on this document should be addressed to U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact in
2、formation can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. AMSC N/A FSC 2940 NOT MEASUREMENT SENSITIVE MIL-DTL-62337C(AT) 10 February 2011 SUPERSEDING MIL-DTL-62337B(AT) 29 April 1999 DETAIL SPECIFICATION AIR
3、CLEANER ASSEMBLY This specification is approved for use by the U.S. Army Tank Automotive Research, Development and Engineering Center (TARDEC), Research, Development and Engineering Command (RDECOM), Department of the Army, and is available for use by all Departments and Agencies of the Department o
4、f Defense. 1. SCOPE 1.1 Scope. This specification covers a 900 cubic foot per minute (ft3/min) 425 liter per second (L/s), fender-mounted, heavy-duty, two-stage, dry-type air cleaner assembly referred to herein as the “assembly” (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in
5、 this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document us
6、ers are cautioned that they must meet all specified requirement documents cited in sections 3 and 4 of this specification, whether or not they are listed. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62337C(AT) 2 2.2 Government documents.
7、2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). FEDERAL STANDARDS F
8、ED-STD-595/24084 - Green, Semigloss. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-62309 - Filter Element, Air. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-810 - Environmental Engineering Considerations and Laboratory Tests (Copies of these documents are available from https:/assist.daps.dla.mil/quicksea
9、rch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified
10、 herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). U.S. ARMY DRAWINGS 11669740 - Air Filter Element. 12325888 - Air Cleaner Assembly - Armored (Clean Air). (Copies of these drawings are available from DAMI_STANDARDIZATIONconu
11、s.army.mil or U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless o
12、therwise specified, the issues of these documents those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62337C(AT) 3 ASTM INTERNATIONAL ASTM C800 - Glass Fiber Blanket Insulation (Aircraft Type
13、) (DoD Adopted). (Copies are available from the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 or website: http:/www.astm.org.) SAE INTERNATIONAL SAE AS478 - Identification Marking Methods (DoD Adopted). (Copies of this document are available from
14、 www.sae.org or SAE Customer Service, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) INTERNATIONAL ORGANIZATION FOR STANDARDIZATIO (ISO) ISO 5011 - Inlet Air Cleaning Equipment for Internal Combustion Engines and Compressors Performance Testing (Copies of these documents are available from www.
15、iso.org or American National Standards Institute, 11 West 42nd Street, New York, N.Y. 10036.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersed
16、es applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.5. 3.2 Material. Materials shall be uniform and free from imperfections or defec
17、ts which affect their serviceability (see 4.8.1). 3.2.1 Corrosion protection. All metallic parts shall be made from corrosion resistant steels or treated/ plated with corrosion-resistant materials (see 3.7.2 and 4.8.1). 3.2.2. Asbestos and cadmium usage. Asbestos and cadmium materials shall not be u
18、sed in any form in any part of the assembly (see 4.8.1). 3.2.3 Radioactive material usage. No item, part or assembly shall contain radioactive materials in which the specific activity is greater than 0.002 microcurie per gram or activity per item equals or exceeds 0.01 microcuries (see 4.8.1). Provi
19、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62337C(AT) 4 3.2.4 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided th
20、at the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs (see 4.8.1). 3.3 Design and construction. The assembly shall be constructed as specified herein and in accordance with Drawing 12325888. The assembly shall incorpora
21、te a precleaner, filter element and a vehicle exhaust dust ejection system (VEDES) precleaner scavenging manifold (see 4.8.1 and 6.2). 3.3.1 Filter element. The filter element shall be in accordance with MIL-PRF-62309 and Drawing 11669740 (see 4.8.1). 3.3.2 Weight. The weight of the assembly shall n
22、ot exceed 600 pounds (lb) (272 kilogram (kg) (see 4.8.1). 3.4 Operating requirements. Except as otherwise specified herein, requirements shall be met under the following standard conditions: a. Temperature: 73 + 18 degrees Fahrenheit (F) (23 + 10 degrees Celsius (C). b. Humidity: 50 + 15 percent (%)
23、. c. Density of air: 0.073 pounds per cubic foot (lb/ft3) 1.17 kilogram per cubic meter (kg/m3) at 80F (27C). d. Pressure: 30 + 1 in. of mercury (Hg) (101 + 3 kilopascals (kPa). e. Dust: Chemical analysis of dust and particle size distribution shall be in accordance with ISO 5011. f. Air flow: 900 f
24、t3/min (425 L/s). g. Dust feed rate: 0.025 + 0.005 gram per cubic foot (g/ft3) (0.88 + 0.18 g/m3) of actual input airflow. Actual input airflow shall be defined as airflow plus the scavenge airflow for each of the five 10 minute stepped airflow cycles listed in table I. (NOTE: First step would have
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL62337C2011AIRCLEANERASSEMBLYPDF