《ARMY MIL-DTL-53133 C-2002 GENERATOR SETS SKID MOUNTED TACTICAL QUIET DIESEL ENGINE DRIVEN ALTERNATING CURRENT 5 THROUGH 60 KILOWATTS GENERAL SPECIFICATION FOR《一般规格的5至60万千瓦交流电 柴油机驱动.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-DTL-53133 C-2002 GENERATOR SETS SKID MOUNTED TACTICAL QUIET DIESEL ENGINE DRIVEN ALTERNATING CURRENT 5 THROUGH 60 KILOWATTS GENERAL SPECIFICATION FOR《一般规格的5至60万千瓦交流电 柴油机驱动.pdf(109页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-53133C 15 April 2002 SUPERSEDING MIL-DTL-0053133B(ME) 13 September 1996 And MIL-DTL-0053133A(ME) 24 July 1995 And MIL-G-53133 30 August 1993 DETAIL SPECIFICATION GENERATOR SETS, SKID MOUNTED, TACTICAL, QUIET, DIESEL ENGINE DRIVEN, ALTERNATING CURRENT 5 THROUGH 60 KILOWATTS GENERA
2、L SPECIFICATION FOR Inactive for new design after 11 August 1997. This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the general requirements for generator sets (hereinafter referred to as “set“ or “sets“
3、), skid mounted, tactical, quiet, alternating current, diesel engine driven, 5 through 60 kilowatts. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: US Army Communications-Electronics Command, A
4、TTN: AMSEL-LC-CCS-G-GB, 10115 Gridley Road Suite 201, Fort Belvoir, VA 22060-5849 by using the Standardization Document Improvement Proposal (DD Form 1426) or by letter. AMSC N/A FSC 6115 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleN
5、o reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53133C 21.2 Classification. The sets will be tactical and of the following modes and sizes: MODE: I - 50/60 Hz II - 400 Hz III - 60 Hz SIZE: 5 - 5 kW, MODE II and III 10 - 10 kW, MODE II and III 15 - 15 kW, MODE I and II (12
6、.5 kW at 50 Hz) 30 - 30 kW, MODE I and II (25 kW at 50 Hz) 60 - 60 kW, MODE I and II (50 kW at 50 Hz) 1.3 Set rating. The set will be rated 0.8 power factor (pf), lagging, and will be re-connectable for the following voltages: - 5/10 kW, 60 Hz and 400 Hz a. 120-volt, single phase, 2 wire b. 120/240-
7、volt, single phase, 3 wire c. 120/208-volt, 3-phase, 4 wire - 15/30/60 kW, 50/60 Hz and 400 Hz a. 120/208-volt, 3-phase, 4 wire b. 240/416-volt, 3-phase, 4 wire 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are needed to meet the requirements specified in sections 3 and 4
8、 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all speci
9、fied requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53133C 32.2.1 Specifications, standards, and handbooks. The
10、 following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto,
11、 cited in the solicitation (see 6.2). SPECIFICATIONS FEDERAL A-A-52557 - Fuel Oil, Diesel; for Posts, Camps and Stations. A-A-52624 - Antifreeze, Multi Engine Type. DEPARTMENT OF DEFENSE MIL-PRF-2104 - Lubricating Oil, Internal Combustion Engine, Combat/Tactical Service. MIL-PRF-2105 - Lubricating O
12、il, Gear, Multipurpose (Metric). MIL-PRF-5624 - Turbine Fuel, Aviation, Grades JP-4 and JP-5/JP-8 ST. MIL-PRF-10924 - Grease, Automotive and Artillery. MIL-F-46162 - Fuel, Diesel, Referee Grade. MIL-PRF-46167 - Lubricating Oil, Internal Combustion Engine, Arctic. MIL-A-53009 - Additive, Antifreeze E
13、xtender, Liquid Cooling Systems. MIL-DTL-83133 - Turbine Fuel, Aviation, Kerosene Type, Grade JP-8. MIL-L-85762 - Lighting, Aircraft, Interior, Night Vision Imaging System (VIS) Compatible. (See Supplement 1 for list of associated specification sheets). STANDARDS DEPARTMENT OF DEFENSE MIL-STD-209 -
14、Slinging and Tiedown Provisions. MIL-STD-461 - Requirements for the Control of Electromagnetic Interference Characteristics of Subsystem and Equipment. * MIL-STD-462B - Measurement of Electromagnetic Interference Characteristics. MIL-STD-705 - Generator Sets, Engine-Driven, Methods of Tests and Inst
15、ructions. MIL-STD-814 - Requirements for Tiedown, Suspension and Extraction Provisions on Military Materiel for Airdrop. MIL-STD-882 - System Safety. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53133C 4MIL-STD-1472 - Human Engineering. *(
16、U)MIL-STD-2169 - High Altitude Electro-Magnetic Pulse Environment (HAEMP).(u) * MIL-STD-462B, dated 11 January 1993, will be used. * (Application for copies of the above classified standard are available to personnel with the appropriate security clearance from Headquarters US Army Communications-El
17、ectronics Command, Research, Development and Engineering Center, Command/Control and Systems, Integration Directorate - South, ATTN: AMSEL-RD-C2-PD-E, 10108 Gridley Road, Suite 1, Ft Belvoir, VA 22060-5817.) HANDBOOKS DEPARTMENT OF DEFENSE MIL-HDBK-454 - Guidelines for Electronic Equipment. MIL-HDBK
18、-705 - Generator Sets, Electrical, Measurements and Instrumentation. MIL-HDBK-784 - Guidelines - Design to Minimize Contamination to Facilitate Decontamination of Military Vehicles and Other Equipment Interiors and Exteriors. MIL-HDBK-1791 - Designing for Internal Aerial Delivery in Fixed Wing Aircr
19、aft. (Unless otherwise indicated, copies of specifications, standards, and handbooks are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to th
20、e extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS specified in the solicitation. Unless otherwise specified, the issues of the documents not listed in the issue of the DoDISS are the issues of the docu
21、ments cited in the solicitation (see 6.2). AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ASQC Z 1.4 - Sampling Procedures and Tables for Inspections by Attributes. (Application for copies should be addressed to: American National Standards Institute, 1430 Broadway, New York NY 10018.) Provided by IHS
22、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-53133C 5NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) MG-1 - Motors and Generators. (Application for copies should be addressed to the National Electrical Manufacturers Association, 2101 L Street, NW, W
23、ashington DC 20037.) UNDERWRITERS LABORATORIES INC. UL-94 Tests for Flammability of Plastic Materials for Parts in Devices and Appliances. (Applications for copies should be addressed to Underwriters Laboratories Inc., 1285 Walt Whitman Road, Mellville L.I., NY 11747.) 2.4 Order of precedence. In th
24、e event of a conflict between the text of this document and the references cited herein, (except for related associated specifications and specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specifi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL53133C2002GENERATORSETSSKIDMOUNTEDTACTICALQUIETDIESELENGINEDRIVENALTERNATINGCURRENT5THROUGH60KILOWATTSGENERALSPECIFICATIONFOR

链接地址:http://www.mydoc123.com/p-444378.html