ARMY MIL-DTL-12713 E-2012 QUADRANT FIRE CONTROL M1A3.pdf
《ARMY MIL-DTL-12713 E-2012 QUADRANT FIRE CONTROL M1A3.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-DTL-12713 E-2012 QUADRANT FIRE CONTROL M1A3.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-DTL-12713E 1 August 2012_ SUPERSEDING MIL-Q-12713D (MU) 10 August 1970 DETAIL SPECIFICATION QUADRANT, FIRE CONTROL: M1A3 This specification is approved for use by all Departments and Agencies of the Department of Defense 1. SCOPE 1.1 Scope. This specification covers Fire Control Quadrant: M1A3,
2、 used primarily for measuring angles of cant or elevation for various trajectory weapons. This item is commonly referred to as the Gunners Quadrant. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does no
3、t include documents in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all requirements of documents cited in sections 3 and 4 of
4、this specification, whether or not documents are listed in this section. Comments, suggestions, or questions on this document should be addressed to: Commander, US Army ARDEC, ATTN: RDAR-QES-E, Picatinny, New Jersey 07806-5000 or emailed to picaardecstdznbranchconus.army.mil. Since contact informati
5、on can change, you may want to verify the currency of this address information using the ASSIST online database at https:/assist.dla.mil. AMSC N/A FSC 1290 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND Provided by IHSNot for ResaleNo reproduction or net
6、working permitted without license from IHS-,-,-MIL-DTL-12713E 2 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of thes
7、e documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-F-13926 - Fire Control Materiel, Manufacture, and Inspection, General Specification for DEPARTMENT OF DEFENSE STANDARDS MIL-STD-1916 - DOD Preferred Methods for Acceptance of Product (Copies of fede
8、ral and military specifications, standards, and handbooks are available online at https:/assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The follo
9、wing other Government documents, drawings, and publications form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. U.S. ARMY ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER (AR
10、DEC) DRAWINGS 13032529 - Quadrant, Fire Control: M1A3 (Application for copies of these drawings may be requested through email to pica.drawing.requestconus.army.mil or from U.S. Army ARDEC, ATTN: RDAR-EIS-PE, Picatinny, NJ 07806-5000) 2.3 Order of precedence. Unless otherwise noted herein or in the
11、contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document shall take precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Re
12、quired inspections. 3.1.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.2.1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12713E 3 3.1.2 Conformance. A sample shall be
13、 subject to conformance inspection in accordance with 4.2.2. 3.2 Final assembly. Item shall conform to drawing 13032529. 3.3 Environmental. 3.3.1 Storage temperature. The quadrant shall be thermally stabilized at temperatures of +160 5 F and -60 5 F for a minimum of 4 hours at each temperature. Upon
14、 return to and stabilization at standard ambient temperature, +60 F to +90 F, the quadrant shall show no evidence of physical damage or failure and meet the requirements of 3.4 through 3.12 inclusive. 3.3.2 Operating temperature. The quadrant shall meet the requirements of 3.4 through 3.9 inclusive
15、while exposed and thermally stabilized at temperatures of +145 5 F and -50 5 F for a period of not less than 4 hours at each temperature. 3.4 End-for-end. The quadrant shall end-for-end with a correction no greater than 0.4 mil. 3.5 Micrometer. An increase of 10 mils of the gunners quadrant micromet
16、er shall result in a 10 mil increase in elevation within the width of a level vial graduation line as read using the gunners quadrant level vial. 3.6 High angle shoes. The gunners quadrant shall provide the same reading within 0.4 mils at 800 mils elevation using the quadrants high angle shoes as wh
17、en using the low angle shoes. 3.7 Accuracy. The gunners quadrant shall indicate angular readings from -10 mils to 1600 mils (with respect to the horizontal plane) accurate within 0.4 mils. 3.8 Torque. The running torque required to rotate the micrometer knob shall not exceed 2.0 inch-pounds througho
18、ut the operating temperature range of -50F to +145F inclusive. 3.9 Index alignment. With the micrometer dial indicating zero, the zero index line on the level vial holder shall coincide with the index line on the arm within the width of the index line on the arm. 3.10 Perpendicularity. The high angl
19、e shoes shall be perpendicular to the low angle shoes within .0004 inches. 3.11 Bubble size. The level vial bubble length shall be .60 .02 inches at 75F. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-12713E 4 3.12 Workmanship. Workmanship o
20、f the M1A3 fire control quadrant shall be in accordance with the requirements of MIL-F-13926. 4. VERIFICATION TABLE I. Requirement/verification cross reference matrix. Method of Verification Class of Verification A - First Article B - Conformance 1 - Analysis 2 - Demonstration 3 - Examination 4 - Te
21、st Section 3 Requirement Description Verification Method Verification Class Section 4 Verification 1 2 3 4 A B 3.1.1 First article X X X 4.2.1 3.1.2 Conformance X X X 4.2.2 3.2 Final assembly X X X X 4.3 3.3.1 Storage temperature X X X 4.4.1 3.3.2 Operating temperature X X X 4.4.2 3.4 End-for-end X
22、X X 4.5 3.5 Micrometer X X X 4.6 3.6 High angle shoes X X X 4.7 3.7 Accuracy X X X 4.8 3.8 Torque X X X 4.9, 4.4.2 3.9 Index alignment X X X 4.10 3.10 Perpendicularity X X X 4.11 3.11 Bubble size X X X 4.12 3.12 Workmanship X X X 4.13 4.1 Classification of inspection. The inspection requirements spe
23、cified herein are classified as follows: a. First article inspection (see 4.2.1) b. Conformance inspection (see 4.2.2) 4.2.1 First article. When specified, a sample shall be subjected to first article verification in accordance with Table II. Provided by IHSNot for ResaleNo reproduction or networkin
24、g permitted without license from IHS-,-,-MIL-DTL-12713E 5 TABLE II. First article inspection criteria. Examination or Test Requirement Paragraph Verification Paragraph Final assembly 3.2 4.3 Storage temperature 3.3.1 4.4.1 Operating temperature 3.3.2 4.4.2 End-for-end 3.4 4.5 Micrometer 3.5 4.6 High
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILDTL12713E2012QUADRANTFIRECONTROLM1A3PDF

链接地址:http://www.mydoc123.com/p-443288.html