1、flIL-C-4OL9 11 = 7997706 03154b5 2 9 MIL-C-48019 (MU) 13 June 1972 MILITARY SPECIFICATION CONNECTOR, ELECTRICAL 1. SCOPE 1.1 This specification covers requirements, quality assurance pro- visions, and the preparation for delivery criteria for one type of connector, electrical used on M454, M455 and
2、T5123El projectiles. 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids or request for proposals, form a part of this specification to the extent specified herein: SPECIFICATIONS MILITARY MIL-P- 116 - Preservation, Methods of STANDARDS MILITARY
3、 MIL-STD-105 - Sampling Procedures and Tables for MIL-STD-1168 - Lot Numbering of Ammunition MIL-STD-1169 - Packaging, Packing, and Marking for Inspection by Attributes Shipments of Inert Ammunition Components DRAWINGS PICATINNY ARSENAL 8808362 - Packing and Marking for Storage and Shipments 8883535
4、 - Bag, Packing, for Repair Parts Fsc 1110 1 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-(2-48019 (MU) 9220308 - Connector, Electrical 92203 12 - Contact, Connector 9220310-2 - Screw, Connector 9220311 - Screw, Guide 9220309 - Connector Bod
5、y Assembly 9220313 - Insulator, Top 9220314 - Body, Connector 9220315 - Seal, Lower 9220322 - Adhesive Sealant ET9220308 - Equipment Tabulation (Copies of specifications, standards, drawings, and publications required by suppliers in connection with specific procurement functions should be obtained
6、from the procuring activity or as directed by the contracting officer. ) 3. REQUIREMENTS 3.1 Materials. The contractor shall furnish objective evidence (see 6.2) that the material complies with the specifications listed on the applicable drawing. 3.2 Assembly, The connector shall comply with all req
7、uirements specified on the drawing (dwg) 9220308, with all requirements specified herein, and with the requirements of all applicable specifications to the extent specified on the drawing and herein. 3.3- Tool manufacturing control (T. M. C. ). When T. M. C. is specified herein, five consecutive par
8、ts which comply with drawing dimensions will constitute proper initial tool control acceptance. Durin; normal production, five parts shall be selected at the start and at the end of each days pro- duction (for a minimum of 10 parts) and examined as specified in the applicable paragraph in 4.3.2.1 In
9、 addition, five consecutive parts shall be examined as specified in the applicable paragraph in 4.3.2.1 whenever the manufacturing tool requires maintenance. Failure of any part to comply with any of the examinations specified in 4.3.2. I shall rejec the lot of production under consideration. 3.4 Wo
10、rkmanship. 3.4. i Plastic and metal characteristics; All components shall be free from cracks, splits, cold flow, shrinkage, cold shuts, inclusions, porosity, or any similar characteristics. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-HIL-*C-4O
11、17 11 W 7779706 0315Li67 b MIL-C-48019 (MU) 3.4.2 Threads. Threads shall be full and undamaged for the entire minimum length or depth as required on the applicable drawing. 3.4.3 Burrs. Parts shall be free from burrs. 3.4.4 Foreign matter. Parts shall be free from chips, dirt, grease, rust, corrosio
12、n, or any embedded foreign material. 3.4.5 Cleaning. The cleaning method shall not be injurious to any of the parts, nor shall the parts be contaminated by the cleaning agent. 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase or
13、der, the supplier is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or order, the supplier may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless d
14、isapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specifica- tion where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2 First article inspection. Not applicable. 4.3 Quality
15、 conformance inspection. 4.3.1 Lot formation. 4.3.1.1 Production lot. A lot shall consist of parts and assemblies produced by one manufacturer in one unchanged process, in accordance with the same drawing, same drawing revision, same specification and same specification revision, Drawing, specificat
16、ion and process changes not affecting safety, performance, storage, or interchangeability, as de- termined by the Government, shall not necessitate changing the lot interfix number. The criteria and procedures for the assignment of lot numbers shall be in accordance with MIL-STD- 1168. 4.3.1.2 Inspe
17、ction lot. A lot or batch and its formation, size, and presentation is described in MIL-STD-105, Section 5. Accordingly, a lot shall mean an inspection lot and a batch shall mean an inspection batch for the purpose of this specification. The manner in which each inspection lot or batch is to be pres
18、ented and identified by the contractor, shall be designated or approved by the Government representative. Critical characteristics shall require 100 percent inspection of all items in the inspection lot. A sample shall be selected at random from each inspection lot in accordance with the ap- plicabl
19、e major or minor characteristic table (see Table I, II, III, and Table IV), and inspected for all characteristics in the applicable classification. Any characteristics in the sample found to be defective shall reject the inspection lot. Sequence for the inspection of characteristics in each classifi
20、cation need not be followed as long as all characteristic inspections are performed. 4.3.2 . Product inspection examination. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-(2-48019 (MU). Table I Major Characteristics for War Reserve Items Lot
21、Size 1-72 73 74 75 76 77 78 79 80 8 li82 83 84 85 86 87 88-89 90 91 92 83 94-95 96 97 98 99-100 101 102 103 104-105 106 107 108-109 110 111 112- 113 114 115 116-117 118 119 120-121 122 123- 124 .125 126-127 12 i28 - 30 13 1 Sample Sample Size LotSize Size Lot Size all 72 73 . 74 75 76 77 78 79 80 81
22、 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 1: 12 113 114 115 116 117 118 140- 14 1 143-144 - 145 146- 147 142 148-149 150 151-152 153-154 155-156 158-159 160- 16 1 162-163 164-165 166- 167 169-170 17 1- 172 173-174 175-176 177-178 179-180 1
23、81-182 185- 187 188- 189 190- 19 1 192-193 194- 195 196-197 198-200 201-202 203-204 205-207 208-209 2 10-2 12 2 13-2 14 215-217 218-219 220-222 223-224 2 2 5-2 27 2 28-230 23 1-232 233-235 236-238 239-241 157 168 1839 184 124 .125 126 127 128 129 130 13 1 13 2 133 134 13 5 136 137 13 8 139 140 14 1
24、142 143 144 145 146 147 14 8 149 150 15 1 152 153 154 155 156 157 158 159 160 16 1 162 163 164 165 166 167 168 I69 170 17 1 256-259 260-262 263-265 266-268 269-271 272-275 276-278 279-282 286-289 290-293 294-296 297-300 301-304 305-308 309-3 12 3 13-3 16 3 17-320 321-324 325-328 330-333 334-338 339-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILC480191972CONNECTORELECTRICAL 电气 连接器 PDF

链接地址:http://www.mydoc123.com/p-441548.html