ARMY MIL-B-63094 B-1978 BLASTING MACHINE 50 CAP M34《10 CAP容量爆破机》.pdf
《ARMY MIL-B-63094 B-1978 BLASTING MACHINE 50 CAP M34《10 CAP容量爆破机》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-B-63094 B-1978 BLASTING MACHINE 50 CAP M34《10 CAP容量爆破机》.pdf(63页珍藏版)》请在麦多课文档分享上搜索。
1、MILIB-63094B (AR) 24 July 1978 S UEERSEDING MIL-B- 63094A (AR) 30 November 1977 MILITARY SPECIFICATION BLASTING MACHINE, 50 CAP, M34 , This specification is approved for use by the U.S. Army Armament Research and Development Command, and is available for use by all Departments and Agencies of the De
2、partment of Defense. I 1. SCOPE 1.1 This specification contains requirements not nor- mally covered by the drawings and provides quality assurance provisions for the fabrication inspection, test and packing for a generator blasting machine designated as the Blasting Machfne, M34. 2. APPLICABLE DOCUM
3、ENTS 2.1 Issues of documents. - The following documents of the issue mct on date of invitation for bids or request for proposals, form a part of this specification to the extent specified herein. SPECIFICATIONS FEDERAL PPP-T-45 - Tape, Gummed, Paper, Reinforced and PPP-B-621 - Boxes, Wood, Nailed an
4、d Lock-corner PPP-B-636 - Box, Fiberboard Plain, for Sealing and Securing . MILITARY MIL-P-116 - Preservation, Methods of MIL-B-117 Packaging MIL-S-4473 - Shieldin Magnetron Tubes and - Bag, Sleeve and Tubing - Interior Magnets B or Air Shipment FSC: 1375 Beneficial comments (recommendations, additi
5、ons, deletions) and any pertinent data which may be of use in improving thin document ahould be addressed to: Commander, US Army Armament Research and Development Command, Attn. DRDARQA, Dover, New Jersey 07801 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426)
6、appearing at the end of this document or by letter. UhEiUT CONTAINS PA45OC -5OC to 52OC +SOC) and in accordance with 4.5.6. 3.7 Service life cycle. - The blasting machine shall 3.8 Extreme temperature performance. - The blasting 3.9 Temperature storage, - The blasting machine shall be capable ot fun
7、ctioning and complying with the requre- ments of 3.3 after seventy two (72) hours of storage and testing as specified in 4.5.7. 3.10 Insulation resistance, - The blasting machine shall conipxy with the requirements of 3.3 after having five hundred volts alternating current (500 VAC) applied between
8、case and each output terminal. for a minimum of ten (10) seconds and. there shall be no evidence of current leakage in excess of ten (10) micro- amperes, The voltage shall be applied Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-B-63094B 13 = 7
9、777906 0343620 7 W - _ MIL-B-63094B (AR) 3.11 Humidit . - The blasting machine shall operate within the requiremd 3.3 after exposure to twenty (20) hours of relative humidity between ninety .two (92) and ninety seven (97) percent at air temperatures from twenty seven degrees Centigrade plus five deg
10、rees Centigrade (27 % + 5 Q) followed by four (4) hours plus one (1) hour of one hundred (100) percent relative humidity with condensation at twenty five degrees Centigrade plus five degrees Centigrade (25 Q + 5%). 3.12 Unactivated voltage. - The output voltage across the output terminals shall be o
11、ne tenth (0.1) volt or less within ten (-10) seconds after the device has complied with the requirements of 3.3 and it is tested in accordance with 45.10. I 3.13 Test temerature. - All testing shall be performed at a temperature of twenty five degrees centi rade plus or otherwise. minus five degrees
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILB63094B1978BLASTINGMACHINE50CAPM3410CAP 容量 爆破 PDF

链接地址:http://www.mydoc123.com/p-441029.html