1、 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. METRIC A-A-59777A 8 January 2009 SUPERSEDING A-A-59777 7 July 2006 COMMERCIAL ITEM DESCRIPTION DRY FILTER UNIT The General Services Administration has authorized the use of this commercial item description, for all fe
2、deral agencies. 1. SCOPE. 1.1 Scope. This commercial item description covers a Dry Filter Unit (DFU). The DFU is an ambient air sampler that can be used to collect airborne biological particles. Those particles may be transferred to a liquid medium, and analyzed for the presence of possible biologic
3、al warfare agents. The DFU is available in two types or configurations. The Type I DFU (also known as DFU-1000) is intended for use in most environmental conditions. The Type II DFU (also known as DFU-2000) is intended for use in nearly all environments. It is better suited for operation in special
4、environments in which air is laden with precipitation, sand, or debris. Both DFU sampler types may operate indoors or outdoors in military and non-military applications. AMSC N/A FSC 6665 Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data which may im
5、prove this document should be sent to: U.S. Army Edgewood Chemical Biological Center, ATTN: AMSRD-ECB-ENA-S, E3331, 5183 Blackhawk Road, Aberdeen Proving Ground, MD 21010-5424 or emailed to APGR-EcbcSpecsTeamus.army.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without li
6、cense from IHS-,-,-A-A-59777A 2 2. CLASSIFICATION. 2.2.1 Type I DFU. Type I DFU includes a blower which draws air from above the unit through a manifold which contains removable filter cartridges. Filtered air discharged from the blower is exhausted through an outlet near the bottom of the DFU. The
7、blower, power cord, spare parts, and consumables are contained within an impact-resistant, portable case equipped with hand-turn fasteners for opening and closing. 2.2.2 Type II DFU. Type II DFU includes the same components of the Type I DFU. All Type I components are contained within a larger, weat
8、her-resistant, secondary enclosure. A stack is mounted on top of the enclosure. A special air inlet pre-separator or shroud on top of the stack is intended to prevent the entrance of precipitation, sand, and debris (e.g. leaves, insects). 3. SALIENT CHARACTERISTICS. 3.1 Operating characteristics. Un
9、less otherwise specified, the following requirements apply to both types of DFUs: 3.1.1 General operation. The DFU shall operate by passing ambient air through filters and collecting airborne particles, manual transfer of particle-laden filters to a conical tube containing phosphate buffer solution,
10、 manually shaking or centrifuging in a conical tube, and manual transfer of liquid droplets to a biological identifier (hand held assay panel). The DFU shall be capable of operating indoors and outdoors on land and aboard ships. 3.1.1 Flow rate. a. Combined air flow through two filters installed in
11、parallel in the intake manifold of the DFU shall be at least 900 liters per minute (lpm). b. Air flow through the DFU with no filters installed in the intake manifold shall be at least 1250 lpm at standard conditions or corrected to standard conditions. In this document, standard conditions are defi
12、ned as one atmosphere (sea level conditions), and a temperature of 20C (68F). 3.1.2 Filter efficiency. a. During operation, each filter shall be able to trap at least 97% of passing particles whose size is one micron or greater. b. During operation at rated flow, the filter shall not experience tear
13、s or holes when dry or wet. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59777A 3 3.1.3 Extraction efficiency. The extraction or elution process, whereby the particles containing biological material collected by the filter are transferred into
14、 the Phosphate Buffer Solution (PBS), shall have an extraction efficiency of at least 50%. 3.1.4 Continuous operation. The DFU shall be capable of continuously collecting material from air samples for at least 8 hours before replacing the collection filter(s). 3.1.5 Power consumption. The DFU shall
15、be capable of operating using 120 or 240 Volts Alternating Current (VAC) with frequency of 50 or 60 Hz supplied by commercial line power or generator input power. CONUS units are shipped with 120 VAC power cord only while OCONUS units are shipped with both 120 and 220 VAC power cords. When input vol
16、tage is 120 VAC, 60 Hz, current shall not exceed 5.0 amperes (except peak power draw shall not exceed 17 amperes during startup). 3.1.6 Noise levels. DFU operating noise levels shall not exceed 60 dB at 61 cm (2 feet) when measured with the DFU in an open-air environment void of any additional ambie
17、nt noise. 3.1.7 Weight. The Type I and II DFU shall be man portable. The maximum weight of the Type I DFU shall be 19.1 kilograms (42 pounds) and the maximum weight of the Type II DFU shall be 38.1 kilograms (84 pounds) without accessories (pre-separator shroud, stack assembly, power cord and its ba
18、g, filter cartridges). Both versions shall be capable of being operated and maintained by personnel representative of the 5thand 95thpercentile. 3.2 Interface and interoperability characteristics. This section includes a brief description of both external and internal interfaces. It also includes so
19、me component functional characteristics in relation to their surrounding parts. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59777A 4 3.2.1 External power interface connections. Plug at end of cable shall be rated at 15 amps or above. Plug con
20、nector details shall be in accordance with Table I and MIL-DTL-5015 for any input AC voltage. TABLE I. Power cable/AC input interface connector and pin-out. Connector Description Reference Designator Pin-Out 3 Chassis GND 2 NEUT Connector 3-position AC Input 1 Applicable* VAC * The DFU shall be capa
21、ble of operating using 120 or 240 Volts Alternating Current (VAC) with frequency of 50 or 60 Hz supplied by commercial line power or generator input power (CONUS units shipped with 120 VAC power cord only while OCONUS units shipped with both 120 and 220 VAC power cords). 3.2.2 Internal power interfa
22、ce connections. This interface allows power input and control from the power source to the DFU. Table II defines the interface between the power cable and DFU. The DFUs connector interfaces with the power cables AC output connector. The DFUs connector has male threads and 6 pins. The cables interfac
23、ing connector has female threads and 6 sockets. Connectors shall have an Ingress Protection (IP) number of 68 (dust tight and protected against immersion). Connector enclosures shall conform to rating 6P in NEMA Standard Publication 250 and IEC 60529. The DFUs power inlet connector will have a capti
24、ve cover to be used when DFU is not in operation. TABLE II. DFU power/ interface connector and pin-out. External Connector Reference Designator Connector Description MIL-SPEC Mating MIL-SPEC DFU Connector, 6-position MIL-DTL-38999 MIL-DTL-38999 Pin # Signal I/O Signal Bus 1 120 VAC I 220 VAC POWER 2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA59777A2009DRYFILTERUNIT 过滤器 PDF