ARMY A-A-59686-2001 PREHEATER ENGINE COOLANT DIESEL-FIRED 24-VOLT DC《24伏直流电柴油燃料发动机冷却预热器》.pdf
《ARMY A-A-59686-2001 PREHEATER ENGINE COOLANT DIESEL-FIRED 24-VOLT DC《24伏直流电柴油燃料发动机冷却预热器》.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-59686-2001 PREHEATER ENGINE COOLANT DIESEL-FIRED 24-VOLT DC《24伏直流电柴油燃料发动机冷却预热器》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、NOT MEASUREMENTSENSITIVEA-A-59686May 25, 2001COMMERCIAL ITEM DESCRIPTIONPREHEATER, ENGINE COOLANT, DIESEL-FIRED, 24-VOLT DCThe General Services Administration has authorized the use of this commercial itemdescription, for all federal agencies.1. SCOPE. This commercial item description (CID) covers r
2、equirements for diesel-fired enginecoolant preheaters, known hereinafter as preheaters. The purpose of a preheater is to preheatwater-cooled diesel engines that are at ambient temperatures from -18 degrees Celsius ( C)to -46 C (0 degrees Fahrenheit ( F) to -50 F) so they can be started without damag
3、ing theengine. Preheaters bought in accordance with (IAW) this CID should not be used on systemswith operational ether start. Type 1 and type 2 preheaters are recommended for enginedisplacements of up to 8 liters (L) (488 cubic inches (in 3 ); Type 3 preheaters are recommendedfor engine displacement
4、s of 9 to 12.5 L (549 to 763 in 3 ).2. CLASSIFICATION. Preheaters shall be of the following types:Type 1 - 2.2 to 5.0 kilowatts (kW) ( 7,5 00 to 17,000 British thermal units per hour(Btu/hr) capacity, with enclosed heater/water pump assembly.Type 2 - 2.2 to 5.0 kW capacity, with heater and water pum
5、p supplied separately, toaccommodate space limitations on host vehicles.Type 3 - 1.5 to 9.0 kW (5,000 to 31,000 Btu/hr) capacity, with enclosed heater/waterpump assembly.Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any datathat may improve this document should
6、 be sent by letter to : U.S. Army Tank-automotive andArmaments Command, ATTN: AMSTA-TR-E/IE, Warren, MI 48397-5000.AMSC N/A FSC 2990DISTRIBUTION STATEMENT A . Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license f
7、rom IHS-,-,-A-A-5968623. SALIENT CHARACTERISTICS.3.1 Materials . Unless specified herein, materials shall be IAW the manufacturers materialspecifications. The use of recovered material made in compliance with regulatory requirementsis acceptable providing that all requirements of this CID are met (s
8、ee 4).3.1.1 Dissimilar metals . Dissimilar metals shall electrically insulated from one another toprevent galvanic corrosion.3.1.2 Fuel resistance . Preheater components that are exposed to fuel shall be resistant to damagecaused by direct contact with the fuel (see 3.2.7.1).3.1.3 Corrosion resistan
9、ce . Preheater components shall be fabricated from compatible materials,inherently corrosion resistant or treated to provide against corrosion and deterioration duringstorage and operation.3.1.4 Hazardous materials . Asbestos and cadmium-plated components shall not be used in thepreheater or any of
10、its components.3.2 Design and construction .3.2.1 Type 1 preheaters . Type 1 preheaters shall have a minimum of two heat settings(high/low) and shall have a heat output capacity of 2.2 to 5.0 kW. Type 1 preheaters shall beprovided with a heater/water pump assembly enclosed in a weather resistant enc
11、losure or boxwith a quick release cover for easy access (see 3.2.6). Type 1 preheaters shall have all interfaceconnections within the enclosure or surface mounted on the exterior of the enclosure. Type 1preheaters shall be provided with the components specified in table I.3.2.2 Type 2 preheaters . T
12、ype 2 preheaters shall have a minimum of two heat settings(high/low) and shall have a heat output capacity of 2.2 to 5.0 kW. Type 2 preheaters shall beprovided as a “kit”, with individual components supplied for specialized installation within ahost vehicle, where space is limited. The kit shall con
13、tain all necessary components for acomplete installation into the host vehicle, including, but not limited to those specified in table I.3.2.3 Type 3 preheaters . Type 3 preheaters shall have a minimum of four heat settings(boost/high/medium/low) or variable heat output, and shall have a heat output
14、 capacity of 1.5 to9.0 kW (see 7.5). Type 3 preheaters shall be provided with a heater/water pump assemblyenclosed in a weather resistant enclosure or box with a quick release cover for easy access(see 3.2. 6). Type 3 preheaters shall have all interface connections within the enclosure or surfacemou
15、nted on the exterior of the enclosure. Type 3 preheaters shall be provided with thecomponents specified in table I.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-596863TABLE I Preheater component list .Component Type 1 Type 2 Type 3Heater/water
16、pump, enclosed X XHeater/water pump, separate XFuel metering pump X X XFuel hose, pressure, 6.1 meters (m) (20 feet (ft.), with clamps X X XFuel hose, suction, 1.8 m (6 ft.), with clamps X X XControl unit/timer and harness (see 3.2.8 and 3.2.9) X X XElectrical harnesses, electrical connectors and wi
17、ring XExhaust pipe X X XFuel tank pick-up pipe and connections X X XMounting brackets/fasteners X X XCoolant hoses and connectors XData plates X X XOperator/maintenance/installation manuals X X X3.2.4 Power requirements . Preheaters shall start and operate at applied voltages between20 - 28.5 volts
18、(V) direct current (dc). Preheaters shall cycle for up to two hours after eachstart -up unles s the operator manually turns it off or a fault occurs. Preheaters shall shut offwhenever low voltage (20 V or less) is detected. Maximum electrical power consumption withwater pump at 24 V shall be as spec
19、ified in table II.TABLE II. Power consumption .Power, watts (W)Preheater typeBoost setting High setting Low setting1 and 2 - 55 353 125 85 373.2.5 Weight and size . Preheater and weather-resistant enclosure shall not exceed the weightsand sizes specified in table III.TABLE III. Weight and size restr
20、ictions .Preheater type Weight, kilograms (kg) (pounds ( lb) Size, millimeter (mm) (inch (in.)1 10.0 (22) 150 x 320 x 240 (6.0 x 12.5 x 9.5)2 1 / 5.0 (11) 250 x 110 x 200 (10.0 x 4.5 x 8.0)3 21.0 (46) 430 x 300 x 230 (17.0 x 12.0 x 9.0)1 / As type 2 preheaters have no enclosure, the restrictions are
21、 for the heater (see 3.2.2).3.2.6 Preheater enclosure . Type 1 and type 3 preheaters (see 3.2.1 and 3.2.3) shall come with anenclosure that can be secured (bolted shut or locked with a padlock). The enclosure shall protectpreheater from outside environment (rain, humidity, dust, snow, salt, engine f
22、luids).Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5968643.2.7 Interfaces and compatibility .3.2.7.1 Fuel compatibility . Preheaters shall operate on and be compatible with diesel fuels IAWA-A-52557, MIL-DTL-83133 (JP-8), ASTM-D1655 (Jet A-1)
23、 and MIL-DTL-5624 (JP-4).3.2.7.2 Coolant compatibility . Preheaters shall be compatible with ethylene glycol (Type IP)and propylene glycol (Type II) based antifreezes IAW A-A-52624. Preheaters shall also becompatible with antifreeze having corrosion inhibitors IAW MIL-A-53009.3.2.7.3 Electrical inte
24、rface . Preheaters shall come with all required wiring harnesses, fuses,relays and mounting hardware, and shall have quick-disconnect waterproof connectors. Allwires shall be distinguishable from each other and match those in the schematic and electricaldiagram provided in the preheater manual and i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA596862001PREHEATERENGINECOOLANTDIESELFIRED24VOLTDC24 直流电 柴油 燃料 发动机 冷却 预热器 PDF

链接地址:http://www.mydoc123.com/p-440384.html