《ARMY A-A-59229-1998 CAP VENT FILLER BATTERY [Superseded ARMY MIL-B-62346 D NOTICE 1 ARMY MIL-B-62346 D ARMY MIL-B-62346 C ARMY MIL-B-62346 B ARMY MIL-B-62346 A ARMY MIL-B-62346 ARM.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-59229-1998 CAP VENT FILLER BATTERY [Superseded ARMY MIL-B-62346 D NOTICE 1 ARMY MIL-B-62346 D ARMY MIL-B-62346 C ARMY MIL-B-62346 B ARMY MIL-B-62346 A ARMY MIL-B-62346 ARM.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、A-A-59229 m 9018054 0000562 42T INCH-POUND A-A-59229 May 20.1998 SUPERSEDING (see 6.6) COMMERCIAL ITEM DESCRIPTION CAP, VENT, FILLER, BATTERY The General Services Administration has authorized the use of this Commercial Item Description (CID) for all federal agencies. 1. SCOPE. This CID covers requi
2、rements for ventlfiller cap for automotive type batteries. The ventfiller cap is intended to be fully functionable for waterproof, low-maintenance, lead-acid batteries and perform either in wet or dry charged conditions. 2. SALIENT CHARACTERISTICS 2.1 Materiais. Materials shall be in accordance with
3、 the manufacturers specifications for the ventfiller cap and shall meet all of the requirements specified herein. The use of recovered materials made in compliance with regulatory requirements is acceptable providing that all requirements of this CID are met (see 3.1,6.3, and 6.4). 2.2 Desirn and co
4、nstruction. The vent/filler cap shall conform to the manufacturers design and construction except for the nominal dimensions and tolerances which shall conform to figure 1. The check valve shall not leak more than 2 drops of water in 1 O seconds when under 78.7 inches 2.0 meters (m) head of water an
5、d shall be designed to open before internal pressures reach 1.5 pounds per square inch (psi) 10.3 kilopascals va) in excess of the internal pressure. When tested as specified, the vendfiller cap shall withstand temperatures Com -34 degrees Fahrenheit (“F) through 250F -48 degrees Celsius (“C) throug
6、h 12loC without cracking, melting, or other damage. To determine conformance to these salient characteristics, each ventIfiller cap under test shall be visually inspected initially to the nominal dimensions and tolerances of figure 1 and then exposed to an ambient temperature of -34F distribution is
7、 unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59229 upon removal from the heat source, each cap shall be inspected for evidence of damage such as cracking, melting, or other deformities. After a cooling period of one hour, each vend
8、filler cap shall be inserted in a fixture or dummy battery arranged so that water pressure can be applied on the outside of the fixture and air pressure on the lower side. Using this fixture, the upper side of each vendfiller cap shall be subjected to a water pressure which exceed the air pressure o
9、n the lower side by the equivalent of a water head of 78.7 inches C2.0 meters (m) (if air pressure is atmospheric). The number of drops of water that leak through each venlfiller cap and the time required (not to be less than one minute) shall be recorded. The water pressure shall then be released a
10、nd the air pressure on the lower side increased to .5 psi 3.45 Ha above the air pressure existing on the upper side. Each vent/filler cap shall open under the specified pressure. 2.3 Absorbent resistant. The vendfiller cap shall be nonabsorbent and acid-resistant. 2.4 Fire retardation. Vendfiller ca
11、p shall not permit ignition of flammable gases in the test battery when tested in accordance with SAE 51495. 2.5 Electrolvte retention. The vent/filler cap shall not allow electrolyte to leak fiom the batteries filled to the specified level with sulfuric battery acid (electrolyte) or equivalent and
12、tilted 45“ in the major axis (X) and minor axis (y) for 30 seconds per axis. The vent/filler cap shall not allow leakage or spillage from the batteries when rotated on those axes. 2.6 Extreme temperature resistance. The vedfiller cap shall evidence no cracking or other damage due to temperature chan
13、ge between 190F through -65F 88“C through -54“C, and no more than .1 psi 0.69 Wal pressure drop in 30 seconds, with .5 psi 3.45 Wal pressure applied to each cell individually after exposure to extreme test temperature. To veri this characteristic the vent caps installed to a dummy battery or fixture
14、 shall be subjected to two thermal shocks with an internal pressure of .5 psi 3.45 Wal applied to each cell for 30 seconds before and after each cycle. Drop in pressure for the individual cells shall be regarded as an indication of leakage. The following procedure for one cycle shall be used: a. Bat
15、teries shall be placed in an ambient temperature of -65F 2 2F -54“C 2 1“C for b. The batteries shall then be placed in an ambient air temperature of 190F c. The batteries shall be allowed to cool gradually to 8 1 OF 24 hours, or until electrolyte is stabilized. SSOC t lCI for 24 hours. 24 hours. 2F
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA592291998CAPVENTFILLERBATTERYSUPERSEDEDARMYMILB62346DNOTICE1ARMYMILB62346DARMYMILB62346CARMYMILB62346BARMYMILB62346AARMYMILB62346ARMPDF

链接地址:http://www.mydoc123.com/p-440302.html